Open Access 15-08-2023 | Editor’s Comment

Should all electrocardiography be ambulatory?

Auteurs: Joris R. de Groot, Ralf E. Harskamp

Gepubliceerd in: Netherlands Heart Journal | Uitgave 9/2023

share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
insite
ZOEKEN
Due to technological advances, electrocardiographic parameters can now be obtained by the lay public without going to a clinic or hospital. Consumer-based wearable devices that allow detection of atrial fibrillation (AF) and other arrhythmias are increasingly being used. Indeed, we have learned that early detection of AF can lead to earlier therapy and prevention of untoward thromboembolic complications. Another lesson learned is that population-based screening with such devices requires a sufficiently high pretest likelihood and a test with sufficient sensitivity and specificity to provide sensible outcomes. An important example in this context is the Apple Heart Study, which provided data on ~ 0.5 million persons who used a smartphone app for AF detection. As participants in that study overall reflected the ‘worried well’, with a very low pretest likelihood of AF, it is not surprising the test characteristics derived from this study were suboptimal [1].
Apart from these considerations, there is a presumption that device-detected AF carries the same stroke risk as clinical AF. However, this is far from certain. We do know that stroke risk is increased in patients with device-detected atrial high rates, but this risk depends, at least in part, on AF duration [24]. Yet, it is not said that the same recommendations for oral anticoagulation apply to patients with overt AF and those with device-detected AF only. For example, The LOOP Study, in which implantable loop recorders were implanted in high-risk patients without AF using a population screening setup, demonstrated that device detection of AF led to increased prescription of anticoagulant drugs but not fewer strokes or lower mortality [5]. This is just an example to show that the availability of more data does not necessarily result in more advanced care. It also illustrates that we should be cautious to overgeneralise findings from one population and healthcare setting to another. Finally, ambulatory monitoring carries the risk of severely increasing the workload of healthcare professionals, as recordings acquired outside the hospital require confirmation, if only for legal responsibility reasons.
The algorithms behind those systems usually do not go further than giving the advice to consult a doctor in case of an abnormal recording. This is irrespective of the notion that machine detection of AF is as accurate as human assessment; it is simply the result of an algorithm that cannot take responsibility for clinical care. Moreover, there are also electrocardiographic findings of which we do not directly know the clinical implications, resulting in additional diagnostic work-up, increased healthcare spending and the risk of unjustly turning a healthy person into a patient.
In this issue of the Netherlands Heart Journal, Bergeman and colleagues present a proof-of-concept study in 235 patients to quantify QT intervals with a 6-lead mobile electrocardiogram (mECG) device (Kardia Mobile 6L; AliveCor, Mountain View, CA, USA) [6]. For AF detection, this device is more accurate than single-lead devices [7]. The authors provide context for their study by stating that repeating 12-lead ECGs can be cumbersome (particularly in a community-based setting) and mECG devices can potentially fill that gap. They show that only 32% of ambulatory recordings were of good quality, whereas the majority (62%) was of acceptable quality and 7% were of insufficient quality. This observation should be kept in mind when considering implementation into clinical practice. All patients also had a 12-lead ECG taken, and in 98%, there was agreement on the rhythm between the mECG and conventional ECG. Heart rate was consistently higher in the mECG recordings than in the conventional ECG recordings, but the mECG was recorded in sitting position, whereas the 12-lead ECG was taken while the patient was supine. PR interval and QRS duration moderately to strongly correlated between the modalities.
Of the 234 mECG recordings, 33 did not allow for QT determination in lead I and 31 not in lead II; neither lead was suitable in 16 patients (7%) [6]. The QT interval could not be measured from lead I or II in 43 and 3 conventional ECGs, respectively, and in neither lead in one patient. The QT interval was 396 ± 30 and 395 ± 30 ms in lead I of the mECG and 12-lead ECG, respectively. The mean absolute QT interval difference using lead I was 14 ± 13 ms, and 44% of the patients showed a < 10 ms difference in this lead, whereas the mean absolute difference in lead II was 12 ± 9 ms (< 10 ms difference in 55% of subjects), which was similar to a previous QT interval comparison between a single-lead mECG and conventional ECG [8]. In patients with QT prolongation > 480 ms, the sensitivity and specificity for QT prolongation were 80% and 99%, respectively.
The authors rightfully make the point that mECG measurement of the QT interval is feasible [6]. Does that imply that we should now have our patients record their QT interval in an ambulatory manner? We are not convinced. First, the indication for QT interval monitoring is usually a condition or a change in medication invoked by a physician. The responsibility for the safe use of such medications lies with that physician and can, in our opinion, not be delegated to patients. Second, an abnormal finding has immediate consequences that can go as far as patient admission to a clinical ward for telemetric monitoring. Hence, it is not illogical to have patients visit their doctor, who can make an ECG and adapt their therapy or admit them when needed.
An ultimate consequence of the possibility of ambulatory QT measurement is that treatment decisions move to primary care and that general practitioners (GPs) will have to provide care for patients at risk of QT prolongation. It can be questioned whether GPs have the infrastructure to provide such care and whether they are motivated to take that responsibility. Patients taking class 1 and class 3 antiarrhythmic drugs for AF are usually followed up in secondary care [9]. We would argue that the same accounts for QT interval monitoring, either in patients at risk of QT prolongation (i.e. those with long QT syndrome) or in patients on QT-prolonging medication. Whether ambulatory recording of the QT interval facilitates that process remains to be determined. As a minimum, an infrastructure that collects data and provides QT measurement is required. Currently, QT measurement requires human confirmation—even when acquired with a mobile device—, which is a time-consuming and costly endeavour. Perhaps the patient should just come to the clinic to have an ECG taken and speak with their treating cardiologist about the consequences of the QT interval they recorded.

Conflict of interest

J. R. de Groot has received research grants through his institution from the Netherlands Enterprise Agency (Rijksdienst voor Ondernemend Nederland), the Dutch Heart Foundation (Hartstichting), AtriCure, Bayer, Boston Scientific, Daiichi Sankyo, Johnson & Johnson and Medtronic and honoraria/speaker’s fees from AtriCure, Bayer, Biotronik, the Cardiovasculair Onderwijs Instituut, Daiichi Sankyo, Medtronic, Novartis and Servier. R. E. Harskamp has received research grants from the Dutch Heart Foundation, the Netherlands Organisation for Scientific Research (NWO) and the Netherlands Organisation for Health Research and Development (ZonMw).
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

Netherlands Heart Journal

Het Netherlands Heart Journal wordt uitgegeven in samenwerking met de Nederlandse Vereniging voor Cardiologie. Het tijdschrift is Engelstalig en wordt gratis beschikbaa ...

Literatuur
2.
go back to reference Van Gelder IC, et al. Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT. Eur Heart J. 2017;38:1339–44.CrossRefPubMed Van Gelder IC, et al. Duration of device-detected subclinical atrial fibrillation and occurrence of stroke in ASSERT. Eur Heart J. 2017;38:1339–44.CrossRefPubMed
3.
go back to reference Bertaglia E, et al. Atrial high-rate episodes: prevalence, stroke risk, implications for management, and clinical gaps in evidence. Europace. 2019;21:1459–67.CrossRefPubMedPubMedCentral Bertaglia E, et al. Atrial high-rate episodes: prevalence, stroke risk, implications for management, and clinical gaps in evidence. Europace. 2019;21:1459–67.CrossRefPubMedPubMedCentral
4.
go back to reference Kaplan RM, et al. Stroke risk as a function of atrial fibrillation duration and CHA(2)DS(2)-VASc score. Circulation. 2019;140:1639–46.CrossRefPubMed Kaplan RM, et al. Stroke risk as a function of atrial fibrillation duration and CHA(2)DS(2)-VASc score. Circulation. 2019;140:1639–46.CrossRefPubMed
5.
go back to reference Svendsen JH, et al. Implantable loop recorder detection of atrial fibrillation to prevent stroke (The LOOP Study): a randomised controlled trial. Lancet. 2021;398:1507–16.CrossRefPubMed Svendsen JH, et al. Implantable loop recorder detection of atrial fibrillation to prevent stroke (The LOOP Study): a randomised controlled trial. Lancet. 2021;398:1507–16.CrossRefPubMed
7.
go back to reference Scholten J, et al. Six-lead device superior to single-lead smartwatch ECG in atrial fibrillation detection. Am Heart J. 2022;253:53–8.CrossRefPubMed Scholten J, et al. Six-lead device superior to single-lead smartwatch ECG in atrial fibrillation detection. Am Heart J. 2022;253:53–8.CrossRefPubMed
8.
go back to reference Beers L, et al. Manual QT interval measurement with a smartphone-operated single-lead ECG versus 12-lead ECG: a within-patient diagnostic validation study in primary care. BMJ Open. 2021;11:e55072.CrossRefPubMedPubMedCentral Beers L, et al. Manual QT interval measurement with a smartphone-operated single-lead ECG versus 12-lead ECG: a within-patient diagnostic validation study in primary care. BMJ Open. 2021;11:e55072.CrossRefPubMedPubMedCentral
9.
go back to reference Piersma FR, et al. Care and referral patterns in a large, dedicated nurse-led atrial fibrillation outpatient clinic. Neth Heart J. 2022;30:370–6.CrossRefPubMed Piersma FR, et al. Care and referral patterns in a large, dedicated nurse-led atrial fibrillation outpatient clinic. Neth Heart J. 2022;30:370–6.CrossRefPubMed
Metagegevens
Titel
Should all electrocardiography be ambulatory?
Auteurs
Joris R. de Groot
Ralf E. Harskamp
Publicatiedatum
15-08-2023
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 9/2023
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-023-01804-0