Skip to main content
Top
Gepubliceerd in:

Open Access 01-12-2012 | Oral presentation

How accurately can surface markers be placed on bony landmarks of the foot?

Auteurs: Alpesh Kothari, Julie Stebbins, Jessica Leitch, Amy Zavatsky

Gepubliceerd in: Journal of Foot and Ankle Research | bijlage 1/2012

share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
insite
ZOEKEN

Background

The use of multi-segment foot models is becoming increasingly popular during clinical gait analysis. While numerous studies have established the repeatability of these models, the accuracy is more difficult to determine since measuring motion of the bones is a challenging task. One assumption influencing model accuracy is that surface markers can be placed precisely over palpated, bony landmarks. The aim of this study is to test this assumption by assessing marker placement using CT scans.

Materials and methods

Twenty female subjects (forty feet) participated in this study. All subjects had ECG electrodes attached to their lower limbs according to the positions required by the Oxford Foot Model [1]. Positioning was performed by a single tester on all subjects. Subjects lay supine in the CT scanner, in a semi-weight-bearing position using a custom-built rig. The anatomical landmarks and the positions of the markers were identified on the scans using a pre-defined protocol. Intra- and inter-rater reliability were assessed. Marker placement accuracy was determined by assessing relevant components of the distance between markers and bony landmarks.

Results

Good intra- and inter-rater reliability was demonstrated for identifying markers on the CT images (Table 1). The average distance between bony landmarks and marker positions differed according to position on the foot (Figure 1). The mean error was lowest for the base of 5th metatarsal marker (1.2 mm) and highest for the base of 1st metatarsal (12.7 mm). There was a systematic offset for this marker, due to slight differences in definition for placing the marker on the skin, and identifying the bony landmark on CT images. Of the nine marker positions analysed, seven markers had a mean error of less than 5 mm.
Table 1
Reliability for identifying landmarks
 
95% confidence interval
Intra-observer (n=3)
0.19 mm - 0.37 mm
Inter-observer (n=3)
0.21 mm - 0.57 mm

Conclusions

Surface markers can be placed accurately over bony landmarks on the foot; however, some positions can be more precisely palpated than others. This should be taken into account when interpreting results from multi-segment foot models.
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://​creativecommons.​org/​licenses/​by/​2.​0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

BSL Podotherapeut Totaal

Binnen de bundel kunt u gebruik maken van boeken, tijdschriften, e-learnings, web-tv's en uitlegvideo's. BSL Podotherapeut Totaal is overal toegankelijk; via uw PC, tablet of smartphone.

Literatuur
1.
go back to reference Stebbins J, Harrington M, Thompson N, Zavatsky AB, Theologis T: Repeatability of a model for measuring multi-segment foot kinematics in children. Gait Posture. 2006, 23: 401-4. 10.1016/j.gaitpost.2005.03.002.CrossRefPubMed Stebbins J, Harrington M, Thompson N, Zavatsky AB, Theologis T: Repeatability of a model for measuring multi-segment foot kinematics in children. Gait Posture. 2006, 23: 401-4. 10.1016/j.gaitpost.2005.03.002.CrossRefPubMed
Metagegevens
Titel
How accurately can surface markers be placed on bony landmarks of the foot?
Auteurs
Alpesh Kothari
Julie Stebbins
Jessica Leitch
Amy Zavatsky
Publicatiedatum
01-12-2012
Uitgeverij
BioMed Central
Gepubliceerd in
Journal of Foot and Ankle Research / Uitgave bijlage 1/2012
Elektronisch ISSN: 1757-1146
DOI
https://doi.org/10.1186/1757-1146-5-S1-O40