01-12-2014 | Research | Uitgave 1/2014 Open Access

Journal of Foot and Ankle Research 1/2014

A comparison of hallux valgus angles assessed with computerised plantar pressure measurements, clinical examination and radiography in patients with diabetes

Tijdschrift:
Journal of Foot and Ankle Research > Uitgave 1/2014
Auteurs:
Daniël MC Janssen, Antal P Sanders, Nick A Guldemond, Joris Hermus, Geert HIM Walenkamp, Lodewijk W van Rhijn
Belangrijke opmerkingen

Electronic supplementary material

The online version of this article (doi:10.​1186/​1757-1146-7-33) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

NAG and GHIMW designed and wrote the research proposal. NAG collected and prepared the data. Statistical analysis was executed by DMCJ and NAG. Data interpretation was done by NAG, DMCJ and APS. Writing of the scientific paper was performed by DMCJ, APS and NAG. JH, GHIMW and LWR read and discussed the manuscript. All authors read and approved the final manuscript.

Abstract

Background

Hallux valgus deformity is a common musculoskeletal foot disorder with a prevalence of 3.5% in adolescents to 35.7% in adults aged over 65 years. Radiographic measurements of hallux valgus angles (HVA) are considered to be the most reproducible and accurate assessment of HVA. However, in European countries, many podiatrists do not have direct access to radiographic facilities. Therefore, alternative measurements are desired. Such measurements are computerised plantar pressure measurement and clinical goniometry. The purpose of this study was to establish the agreement of these techniques and radiographic assessments.

Methods

HVA was determined in one hundred and eighty six participants suffering from diabetes. Radiographic measurements of HVA were performed with standardised static weight bearing dorsoplantar foot radiographs.
The clinical goniometry for HVA was measured with a universal goniometer. Computerised plantar pressure measurement for HVA was executed with the EMED SF-4® pressure platform and Novel-Ortho-Geometry software. The intra-class correlation coefficients (ICC) and levels of agreement were analysed using Bland & Altman plots.

Results

Comparison of radiographic measurements to clinical goniometry for HVA showed an intraclass correlation coefficient (ICC) of 0.81 (95% confidence interval, 0.76 to 0.86; p<0.001). Radiographic measurement versus computerised plantar pressure measurement showed an ICC of 0.59 (95% confidence interval, 0.49 to 0.68; p<0.001). In addition, clinical goniometry versus computerised plantar pressure measurement showed an ICC of 0.77 (95% confidence interval, 0.70 to 0.82; p<0.001). The systematic difference of the computerised plantar pressure measurement compared with radiographic measurement and clinical goniometry was 7.0 degrees (SD 6.8) and 5.2 degrees (SD 5.0), respectively. The systemic difference of radiographic measurements compared with clinical goniometry was 1.8 degrees (SD 5.0).

Conclusions

The agreement of computerised plantar pressure measurement and clinical goniometry for HVA compared to radiographic measurement of HVA is unsatisfactory. Radiographic measurements of HVA and clinical goniometry for HVA yield better agreement compared to radiographic measurements and computerised plantar pressure measurement. The traditional radiographic measurement techniques are strongly recommended for the assessment of HVA.

Onze productaanbevelingen

BSL Podotherapeut Totaal

Binnen de bundel kunt u gebruik maken van boeken, tijdschriften, e-learnings, web-tv's en uitlegvideo's. BSL Podotherapeut Totaal is overal toegankelijk; via uw PC, tablet of smartphone.

Extra materiaal
Authors’ original file for figure 1
13047_2013_754_MOESM1_ESM.tif
Authors’ original file for figure 2
13047_2013_754_MOESM2_ESM.tif
Authors’ original file for figure 3
13047_2013_754_MOESM3_ESM.tif
Authors’ original file for figure 4
13047_2013_754_MOESM4_ESM.tif
Authors’ original file for figure 5
13047_2013_754_MOESM5_ESM.tif
Authors’ original file for figure 6
13047_2013_754_MOESM6_ESM.tif
Authors’ original file for figure 7
13047_2013_754_MOESM7_ESM.tif
Authors’ original file for figure 9
13047_2013_754_MOESM8_ESM.jpeg
Authors’ original file for figure 10
13047_2013_754_MOESM9_ESM.jpeg
Authors’ original file for figure 11
13047_2013_754_MOESM10_ESM.jpeg
Literatuur
Over dit artikel

Andere artikelen Uitgave 1/2014

Journal of Foot and Ankle Research 1/2014 Naar de uitgave