CC BY 4.0 · Eur J Dent 2024; 18(01): 182-195
DOI: 10.1055/s-0043-1763498
Original Article

Reliability of an Innovative Slab Shear versus Microtensile Bond Strength Test: Mechanical and Finite Element Analysis

Emad Abd Elfatah Abo-Alazm
1   Department of Restorative Dentistry, Egyptian Russian University, Badr City, Cairo Governorate, Egypt
,
2   Department of Prosthetic Dentistry, Biomaterials Division, Faculty of Dentistry, King Salman International University, El Tur, South Sinai, Egypt
,
Layla Hassouneh
3   Department of Conservative Dentistry, Jordan University of Science and Technology, Ar-Ramtha, Jordan
,
4   Department of Conservative Dentistry, Suez Canal University, Ismailia Governorate, Egypt
› Author Affiliations

Abstract

Objective The aim of this study was to evaluate the efficiency of slab shear bond strength test (Slab_SBS) versus the microtensile in evaluation of the bond strength of different substrates.

Materials and Methods Forty-eight extracted caries-free human third molars were utilized for teeth specimens' preparation. After flattening of all molars' occlusal table, the specimens were divided into two groups based on the type of utilized restorative material: nanohybrid resin composite and resin-modified glass ionomer (RMGI). Each group was further subdivided into three subgroups according to the subsequently applied bond strength test and specimen width; microtensile bond strength test (μTBS), Slab_SBS [2 mm] and Slab_SBS [3 mm]. Both testing methods were additionally applied on CAD/CAM specimens, nanohybrid resin composite blocks (composite-to-composite), and ceramic blocks (ceramic-to-ceramic). CAD/CAM specimens were prepared and cemented and then sectioned and subdivided as followed for teeth specimens' preparation. Pretest failures (PTF), bond strength, and failure mode of each specimen were recorded. Representative three-dimensional (3D) finite element analysis (FEA) models were developed to simulate μTBS and Slab_SBS specimens. Data were statistically analyzed using Shapiro–Wilk test and Weibull analysis.

Results Pretest failures were only noted in the μTBS subgroups. Slab_SBS provided comparable bond strength to the μTBS of all substrates with adhesive mode of failure.

Conclusion Slab_SBS is easier to prepare with consistent and predictable outcome with no pretest failures during specimen preparation and better stress distribution.

Supplementary Material



Publication History

Article published online:
14 April 2023

© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India