Skip to main content
Top
Gepubliceerd in: Journal of Foot and Ankle Research 1/2008

Open Access 01-12-2008 | Research

Ultrasound evaluation of the abductor hallucis muscle: Reliability study

Auteurs: Alyse FM Cameron, Keith Rome, Wayne A Hing

Gepubliceerd in: Journal of Foot and Ankle Research | Uitgave 1/2008

share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
insite
ZOEKEN

Abstract

Background

The Abductor hallucis muscle (AbdH) plays an integral role during gait and is often affected in pathological foot conditions. The aim of this study was to evaluate the within and between-session intra-tester reliability using diagnostic ultrasound of the dorso-plantar thickness, medio-lateral width and cross-sectional area, of the AbdH in asymptomatic adults.

Methods

The AbdH muscles of thirty asymptomatic subjects were imaged and then measured using a Philips HD11 Ultrasound machine. Interclass correlation coefficients (ICC) with 95% confidence intervals (CI) were used to calculate both within and between session intra-tester reliability.

Results

The within-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.99–0.99); medio-lateral width an ICC: of 0.97 (95% CI: 0.92–0.97) and cross-sectional area an ICC of 0.98 (95% CI: 0.98–0.99). Between-session reliability results demonstrated for dorso-plantar thickness an ICC of 0.97 (95% CI: 0.95 to 0.98); medio-lateral width an ICC of 0.94 (95% CI 0.90 to 0.96) and for cross-sectional area an ICC of 0.79 (95% CI 0.65 to 0.88).

Conclusion

Diagnostic ultrasound has the potential to be a reliable tool for evaluating the AbdH muscle in asymptomatic subjects. Subsequent studies may be conducted to provide a better understanding of the AbdH function in foot and ankle pathologies.
Opmerkingen

Electronic supplementary material

The online version of this article (doi:10.​1186/​1757-1146-1-12) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

AC carried out the literature review, piloting, data collection and drafted the manuscript. KR and WH participated in the design of the study, statistical analysis and drafting of the manuscript. All authors read and approved the final manuscript.

Background

The intrinsic muscles of the foot work as a functional unit in order to dynamically stabilise and assist in the support of the medial longitudinal arch [13]. The abductor hallucis muscle (AbdH) is the most medial muscle in the first layer of intrinsic muscles of the plantar surface of the foot. The proximal attachment is from the medial process of the calcaneus tuberosity, and its distal attachment is the proximal phalanx with or without attachment onto the medial sesamoid bone, or with insertion exclusively at the medial sesamoid bone [4]. As the tendon lies beneath the transverse axis of the first metatarsal, AbdH performs abduction and plantar flexion of the first metatarsal phangeal joint [5], being active in the late stance and toe-off phases of gait [6], and is a dynamic stabiliser of the longitudinal arch [7]. Musculoskeletal conditions such as hallux valgus (commonly known as a bunion) and pes planus can result in the structure and function of AbdH being adversely affected [5, 8].
An observation commonly seen in patients with diabetes is atrophy of the intrinsic foot muscles, including AbdH, secondary to peripheral motor neuropathy [9]. Atrophy of the intrinsic foot muscle, which is a close representative of the level of motor dysfunction, is understood to result in an imbalance and altered arrangement, thereby causing prominent metatarsal heads, clawing of the toes, and the development of pressure areas predisposing to possible foot ulceration [9, 10]. Alternatively, previous studies have also suggested that the muscle's anatomical line is altered and the strength of the muscle is compromised, consequently affecting the biomechanics of gait, the medial longitudinal arch configuration, and degenerative pes planus [5, 811].
In hallux valgus the AbdH muscle is at a mechanical disadvantage as the distance between the proximal and distal attachments is increased, resulting in the muscle losing its abduction force [8, 12]. An imbalance between the muscles of AbdH and Adductor hallucis muscle, which are responsible for coordinating the first metatarsophalangeal joint movements, is also evident, possibly leading to joint deformity [13]. These effects have been demonstrated to increase the load on the posterior tibial muscle, further increasing the likelihood of dysfunction [13].
There are a number of non-invasive techniques to image soft tissue structures. These include magnetic resonance imaging (MRI), computerized tomography (CT), and ultrasound (US), although not all are feasible or practical to operate in the clinical environment. Electromyography (EMG) has also been utilised to measure skeletal muscle activity [14]. Current evidence suggests a good correlation between ultrasound imaging and the "gold standard" of MRI and CT [15]. Furthermore, muscle imaging techniques such as MRI and US have been shown to be of value in inflammatory myopathies [15]. Ultrasound imaging is safe, non-invasive, easily performed and is a considerably less expensive process to undertake, all making it an advantageous piece of clinical equipment [16]. Ultrasonography has also already been shown to be a valid and reliable tool diagnostically in the imaging of skeletal muscle, producing quantitative and qualitative information about muscle architecture [17].
Ultrasound imaging has previously been used for measuring and analysing muscle cross-sectional area of vastus lateralis [18], lumber multifidus [19], and a range of intrinsic foot muscles that includes extensor digitorum brevis, the first interosseus dorsalis muscle, adductor hallucis and the first lumbrical muscle [11]. Ultrasound imaging has previously been used on the foot to measure plantar fascia band thickness in symptomatic and asymptomatic feet and to establish a plantar fasica index [20]. Methodologically, previous studies have used anatomical landmarks as reference points for the perpendicular position of the transducer in relation to the long axis of the limb, in a set repeatable patient position for carrying out the imaging of the identified muscle [11, 1921]. Quantitative analyses of the intrinsic foot muscles, including AbdH, have predominantly been performed on cadaveric feet through dissection [2, 22]; however, to date there appears to be no studies that have measured AbdH in the asymptomatic population using ultrasonography. This may be beneficial for the diagnosis of pathology, monitoring adaptations, and providing evidence for the effectiveness of non-surgical interventions in relation to the AbdH muscle.
The aim of this study was to evaluate intra-tester within and between-session reliability using diagnostic ultrasound imaging of the AbdH dorso-plantar thickness, medio-lateral width and cross-sectional area.

Methods

Subjects

A convenience sample of thirty subjects were recruited from the University population. Subjects were included if they reported no history of inflammatory arthritis, previous foot or ankle surgery, diabetes, lower limb amputation, or severe hallux valgus as defined by the Manchester Scale [23]. All subjects provided written informed consent. The procedures used in this study were approved by the Universities Ethics Committee.

Equipment

A Philips HD11 Ultrasound machine linear probe (L12-5 MHz, 50 mm broadband linear array) was used to scan images of the AbdH muscle. An Aquaflex® Ultrasound Gel Pad (Fairfield, USA) was applied directly on the skin superficial to the AbdH muscle for optimal transducer contact and signal penetration. A stable platform held the foot in neutral position at zero degrees. Philips Q-lab Software (Release 5.0) was employed for data quantification.

Experimental procedure

Subjects were laid in a supine position. The heel and plantar aspect, excluding the first metatarsal, of the involved foot rested against a stable platform designed to fix the ankle in a zero degree neutral position. The posterior aspect of the knee was supported in approximately 15 degrees flexion. The uninvolved leg was also supported.
The researcher (AC) palpated the bony anatomical landmark of the anterior aspect of the medial malleolus and a perpendicular scanning line was drawn directly inferiorly. The ultrasound gel pad was applied onto the AbdH muscle belly, inferior to the medial malleolus. Scanning occurred with the transducer applied at a perpendicular angle to the aforementioned scanning line and long axis of the foot on the proximal aspect of the reference line to encompass the muscle fibres of AbdH. Minimal pressure was applied with the transducer to reduce any possible alterations to the muscle architecture (Figure 1).
Using digital callipers, the dorso-plantar thickness and medial-lateral width of the AbdH was measured from the echogenic tissue interface between the muscle belly and the muscle fascia (Figure 2). The cross-sectional area measurement of the AbdH muscle was obtained through manual tracing of the muscle borders using the Philips Q-lab Software digital trace with edged detection capabilities (Figure 3).
The left and right foot AbdH muscle were scanned for digital investigation, and three separate repetitions of each foot were recorded in order to attain a mean measurement for each subject. The paired data was collapsed into a single measure by taking the mean of the left and right feet. The probe was reset in its holding port between each scan. This entire process was then repeated three to seven days later to gain between day test results. All ultrasonic imaging measurements were undertaken by AC who was a novice researcher but with training using US imaging over 3-months in a musculoskeletal paper run at the university. Additional training in scanning was undertaken prior to data collection by an experienced radiologist and sonographer based from the clinical scanning unit at the University Scanning Unit. In addition, one-to-one training sessions were undertaken with an experienced researcher in musculoskeletal US, Analysis was undertaken retrospectively and at the time of scanning to ensure blinding of the results. All images of the AbdH muscle captured were stored on the hard drive for later analysis.

Data analysis

The baseline descriptive information from each subject was obtained. An analysis of the reliability of muscle cross-sectional area, medio-lateral width and dorsal-plantar thickness was conducted out using SPSS (version 15, SPSS Inc., Chicago, IL) Repeated measures (test-retest) reliability analyses utilised interclass correlation coefficients (ICC, 3.1) and 95% confidence intervals were obtained. As with other reliability coefficients, there is no standard acceptable level of reliability using the ICC [24]. It is stated that any measure should have an ICC of at least 0.6 to be useful [25]. Bland-Altman plots have been used to provide graphical representation of some of the key reliability findings [26, 27]. The Bland-Altman method calculates the range within which the difference between the two occasions will lie with a probability of 95% [26, 27].

Results

Thirty subjects (20 female and 10 male) completed the study with a mean age of 28.24 ± 10.15 years, mean weight of 68.8 ± 12.35 Kg, and a mean height of 1.71 ± 0.97 m. Descriptive information of the AbdH muscle medio-lateral width, dorso-plantar thickness and cross-sectional area are presented in Table 1.
Table 1
Descriptive statistics of abductor hallucis muscle parameters.
Parameter
Day
Mean ± SD
ICC (95% CI)
Dorso-Plantar Thickness (mm)
1
11.55 ± 1.09
0.97 (0.98–0.99)
 
2
11.52 ± 1.03
0.97 (0.98–0.99)
Medio-lateral Width (mm)
1
28.98 ± 2.69
0.97 (0.95–0.98)
 
2
29.03 ± 2.54
0.97 (0.95–0.98)
Cross-sectional Area (mm2)
1
269.23 ± 35.47
0.98 (0.96–0.99)
 
2
276.55 ± 33.98
0.95 (0.92–0.97)
With respect to within-session reliability the results demonstrated high reliability for all three parameters measured (Table 2). Based on an average of the three repetitions, between-session reliability (Table 3) showed high agreement of measuring the dorso-plantar thickness of AbdH (ICC: 0.97; 95% CI: 0.95 to 0.98). High reliability was evident for medio-lateral width measurements (ICC: 0.94; 95% CI 0.90 to 0.96). Cross-sectional area of the AbdH was deemed as acceptable (ICC 0.79; 95% CI 0.65 to 0.88). Figure 4 illustrates the Bland & Altman plot between Session 1 and Session 2 for AbdH medio-lateral width, with a 95% limits of agreement, bias of -0.05, with SD of bias of 1.27 (Lower limit -2.54, Upper limit 2.44).
Table 2
Intratester within session reliability ICC values.
Parameter
Day
ICC (95% CI)
Dorso-Plantar Thickness (mm)
1
0.97 (0.98–0.99)
 
2
0.97 (0.98–0.99)
Medio-lateral Width (mm)
1
0.97 (0.95–0.98)
 
2
0.97 (0.95–0.98)
Cross-sectional Area (mm2)
1
0.98 (0.96–0.99)
 
2
0.95 (0.92–0.97)
Table 3
Intratester between-session reliability ICC values.
Parameter
ICC (95% CI)
Dorso-Plantar Thickness (mm)
0.97 (0.95–0.98)
Medio-lateral Width (mm)
0.94 (0.90–0.96)
Cross-sectional Area (mm2)
0.79 (0.65–0.88)
Figure 5 illustrates the Bland & Altman plot between Session 1 and Session 2 for AbdH dorso-plantar thickness, displaying a 95% limits of agreement, bias of -0.024, with SD of bias of 0.35 (Lower limit -0.67, Upper limit 0.72). Figure 6 illustrates the Bland & Altman plot between Session 1 and Session 2 for AbdH cross-sectional area, with a 95% limits of agreement, bias of -7.3, with SD of bias of 28.50 (Lower limit -63.18, Upper limit 48.54).

Discussion

With any measuring system there needs to be of proven reliability and validity before being applied in a clinical setting, so that clinicians maybe assured of reproducible and meaningful results. Evaluating the reliability of muscle parameters has been in the past difficult. Only with an increase in accessibility to the higher-end US machines and also the development and increase in availability of low-cost musculoskeletal US machines has it been possible to conduct good reliability studies.
There is limited research exploring the AbdH muscle characteristics. There are however, previous studies utilising US, which have demonstrated that it is a statistically valid and reliable method for assessing the cross-sectional area of skeletal muscle [11, 18]. A study by Reeves et al (2007) [18] observed measuring the cross-sectional area of vastus lateralis using US, comparing results to that of the findings from MRI (Table 4). Also a previous study used US to determine the cross-sectional area of extensor digitorum brevis, which again proved to be a reliable method of measurement (Table 4) [11]. Few studies to date have looked at measuring the muscle parameters of width and thickness using US imaging. An earlier study completed a within-session intra-tester and inter-tester reliability study to measure the thickness of multifidus muscle using US, which concluded in a very high inter-rater agreement of the thickness across both assessors (Table 4), therefore indicating that the aforementioned parameters can be measured reliably [19]. The current study's methodology using US was developed based on the protocols of previous work. These included the utilisation of anatomical landmarks as reference points, allowing time for muscle fluid shifts to occur before scanning, the perpendicular transducer angle, and neutral testing position of the ankle [20, 26, 28].
Table 4
Comparison of results gained from other ultrasound studies measuring muscle parameters.
Study
Parameter
Results
Severinsen & Andersen (2007) 25
Cross sectional area: extensor digitorum brevis
r = 0.75
Reeves et al (2004) 21
Cross sectional area: vastus lateralis
ICC = 0.99
Wallwork et al (2007) 29
Width: L2–L3 Multifidus
ICC = 0.96
 
Width: L4–L5 Multifidus
ICC = 0.97
From a clinical perspective, the role of the AbdH muscle is still yet to be determined but previous work suggests that the AbdH muscle and its distal attachment play an important role in the aetiology as well as in therapy of hallux valgus [5, 29, 30]. In orthopaedic, plastic and reconstructive surgery the AbdH muscle allows for rising interest as it is taken as a graft for flap-surgery [5]. Hypertrophy of the AbdH muscle have been reported to be an aetiological factor in tarsal tunnel syndrome [31]. Myofascial syndrome of AbdH muscle has been reported to cause heel pain [32] and acupuncture meridians utilising the muscle belly of AbdH muscle has also been reported in the literature [33]. However, the previous studies on evaluating the muscle parameters of the AbdH muscle has been limited by questions related to the reliability, validity, standardisation, methodology, and the ability to detect changes over time. The current study, by assessing the within and between session reliability of image acquisition of the AbdH muscle using a standardised methodology to measure medio-lateral width, dorso-plantar thickness and cross-sectional area demonstrated high intra-tester reliability.
Limitations to the current study included measurement error in evaluating the cross-sectional area of AbdH through manual digital trace. Future digital/computer generated mapping of the muscle cross-sectional is a possibility; Reeves et al (2004) [18] reported that reducing measurement error could be undertaken by comparing US cross-sectional results to that taken from an MRI in order to assure the accuracy of the cross-sectional area. However, this is a costly method to adopt in the clinical setting. In the current study, the ultrasonographer was not blinded to the identity of the subjects examined, but randomising the sequence and subjects reduced the potential for bias. Future studies may consider blinding the ultrasonographer to reduce measurement error. Inter-tester reliability was not assessed in the current study but is being planned for future work. A further limitation is the issue of obtaining the spatial relationship of irregular anatomical structure such as the AbdH muscle using 2D sonography. Future work may take into account 3D measurements in conjunction with new technology. Utilising 3D US transducers are planned for future research using the Philips U22 which has 3/4D capabilities. Previous work on multifidus reported on the muscle activity using EMG simultaneously with measuring and monitoring the muscle with US [34]. Future work could utilise the current standard method in conjunction with EMG to evaluate functional parameters of AbdH muscle in conditions such as hallux valgus and tarsal tunnel syndrome.

Conclusion

Using US in the current study baseline results have been reported for intra-tester reliability in the measurement of the AbdH muscle. Future studies using the current protocol may give a clearer understanding of the role the AbdH muscle plays in pathological conditions that may impact on the foot and ankle.

Acknowledgements

Foot Science International Ltd (Christchurch, New Zealand) for their support in this research project.
Open Access This article is published under license to BioMed Central Ltd. This is an Open Access article is distributed under the terms of the Creative Commons Attribution License ( https://​creativecommons.​org/​licenses/​by/​2.​0 ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

AC carried out the literature review, piloting, data collection and drafted the manuscript. KR and WH participated in the design of the study, statistical analysis and drafting of the manuscript. All authors read and approved the final manuscript.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

BSL Podotherapeut Totaal

Binnen de bundel kunt u gebruik maken van boeken, tijdschriften, e-learnings, web-tv's en uitlegvideo's. BSL Podotherapeut Totaal is overal toegankelijk; via uw PC, tablet of smartphone.

Literatuur
1.
go back to reference Fiolkowski P, Brunt D, Bishop M, Woo R, Horodyski M: Intrinsic pedal musculature support of the medial longitudinal arch: an electromyography study. J Foot Ankle Surg. 2003, 42 (6): 327-33. 10.1053/j.jfas.2003.10.003.CrossRefPubMed Fiolkowski P, Brunt D, Bishop M, Woo R, Horodyski M: Intrinsic pedal musculature support of the medial longitudinal arch: an electromyography study. J Foot Ankle Surg. 2003, 42 (6): 327-33. 10.1053/j.jfas.2003.10.003.CrossRefPubMed
2.
go back to reference Kura H, Luo ZP, Kitaoka HB, An KN: Quantitative analysis of the intrinsic muscles of the foot. Anat Rec. 1997, 249 (1): 143-51. 10.1002/(SICI)1097-0185(199709)249:1<143::AID-AR17>3.0.CO;2-P.CrossRefPubMed Kura H, Luo ZP, Kitaoka HB, An KN: Quantitative analysis of the intrinsic muscles of the foot. Anat Rec. 1997, 249 (1): 143-51. 10.1002/(SICI)1097-0185(199709)249:1<143::AID-AR17>3.0.CO;2-P.CrossRefPubMed
3.
go back to reference Mann R, Inman VT: Phasic activity of intrinsic muscles of the foot. J Bone Joint Surg Am. 1964, 46: 469-81.PubMed Mann R, Inman VT: Phasic activity of intrinsic muscles of the foot. J Bone Joint Surg Am. 1964, 46: 469-81.PubMed
4.
go back to reference Drake RL, Vogl W, Mitchell AWM, Gray H: Gray's anatomy for students. 2005, Philadelphia: Elsevier/Churchill Livingstone Drake RL, Vogl W, Mitchell AWM, Gray H: Gray's anatomy for students. 2005, Philadelphia: Elsevier/Churchill Livingstone
5.
go back to reference Brenner E: Insertion of the abductor hallucis muscle in feet with and without hallux valgus. Anat Rec. 1999, 254 (3): 429-34. 10.1002/(SICI)1097-0185(19990301)254:3<429::AID-AR14>3.0.CO;2-5.CrossRefPubMed Brenner E: Insertion of the abductor hallucis muscle in feet with and without hallux valgus. Anat Rec. 1999, 254 (3): 429-34. 10.1002/(SICI)1097-0185(19990301)254:3<429::AID-AR14>3.0.CO;2-5.CrossRefPubMed
6.
go back to reference Reeser LA, Susman RL, Stern JT: Electromyographic studies of the human foot: experimental approaches to hominid evolution. Foot Ankle. 1983, 3 (6): 391-407.CrossRefPubMed Reeser LA, Susman RL, Stern JT: Electromyographic studies of the human foot: experimental approaches to hominid evolution. Foot Ankle. 1983, 3 (6): 391-407.CrossRefPubMed
7.
go back to reference Wong YS: Influence of the abductor hallucis muscle on the medial arch of the foot: a kinematic and anatomical cadaver study. Foot Ankle Int. 2007, 28 (5): 617-20. 10.3113/FAI.2007.0617.CrossRefPubMed Wong YS: Influence of the abductor hallucis muscle on the medial arch of the foot: a kinematic and anatomical cadaver study. Foot Ankle Int. 2007, 28 (5): 617-20. 10.3113/FAI.2007.0617.CrossRefPubMed
8.
go back to reference Arinci Incel N, Genc H, Erdem HR, Yorgancioglu ZR: Muscle imbalance in hallux valgus: an electromyographic study. American Journal Of Physical Medicine & Rehabilitation/Association Of Academic Physiatrists. 2003, 82 (5): 345-9. 10.1097/00002060-200305000-00003. Arinci Incel N, Genc H, Erdem HR, Yorgancioglu ZR: Muscle imbalance in hallux valgus: an electromyographic study. American Journal Of Physical Medicine & Rehabilitation/Association Of Academic Physiatrists. 2003, 82 (5): 345-9. 10.1097/00002060-200305000-00003.
9.
go back to reference Greenman RL, Khaodhiar L, Lima C, Dinh T, Giurini JM, Veves A: Foot small muscle atrophy is present before the detection of clinical neuropathy. Diabetes Care. 2005, 28 (6): 1425-30. 10.2337/diacare.28.6.1425.CrossRefPubMedPubMedCentral Greenman RL, Khaodhiar L, Lima C, Dinh T, Giurini JM, Veves A: Foot small muscle atrophy is present before the detection of clinical neuropathy. Diabetes Care. 2005, 28 (6): 1425-30. 10.2337/diacare.28.6.1425.CrossRefPubMedPubMedCentral
10.
go back to reference Andersen H, Gjerstad MD, Jakobsen J: Atrophy of foot muscles. Diabetes Care. 2004, 27 (10): 2382-5. 10.2337/diacare.27.10.2382.CrossRefPubMed Andersen H, Gjerstad MD, Jakobsen J: Atrophy of foot muscles. Diabetes Care. 2004, 27 (10): 2382-5. 10.2337/diacare.27.10.2382.CrossRefPubMed
11.
go back to reference Severinsen K, Andersen H: Evaluation of atrophy of foot muscles in diabetic neuropathy – a comparative study of nerve conduction studies and ultrasonography. J Clin Neurophysiol. 2007, 118 (10): 2172-5. 10.1016/j.clinph.2007.06.019.CrossRef Severinsen K, Andersen H: Evaluation of atrophy of foot muscles in diabetic neuropathy – a comparative study of nerve conduction studies and ultrasonography. J Clin Neurophysiol. 2007, 118 (10): 2172-5. 10.1016/j.clinph.2007.06.019.CrossRef
12.
go back to reference Jahss M: Disorders of the hallux and the first ray. Disorders of the Foot and Ankle. 1992, 2: 943-72. Jahss M: Disorders of the hallux and the first ray. Disorders of the Foot and Ankle. 1992, 2: 943-72.
13.
go back to reference Incel A, Genc H, Erdem HR, Yorgancioglu ZR: Muscle imbalance in hallux valgus: an electromyographic study. Am J Phys Med Rehabil. 2003, 82 (5): 345-9. 10.1097/00002060-200305000-00003. Incel A, Genc H, Erdem HR, Yorgancioglu ZR: Muscle imbalance in hallux valgus: an electromyographic study. Am J Phys Med Rehabil. 2003, 82 (5): 345-9. 10.1097/00002060-200305000-00003.
14.
go back to reference Calancie B, Molano MR, Broton JG: Abductor hallucis for monitoring lower-limb recovery after spinal cord injury in man. J Spinal Cord Med. 2004, 42 (10): 573-80. 10.1038/sj.sc.3101640.CrossRef Calancie B, Molano MR, Broton JG: Abductor hallucis for monitoring lower-limb recovery after spinal cord injury in man. J Spinal Cord Med. 2004, 42 (10): 573-80. 10.1038/sj.sc.3101640.CrossRef
15.
go back to reference Reimers CD, Finkenstaedt M: Muscle imaging in inflammatory myopathies. Curr Opin Rheumatol. 1997, 9: 475-85. 10.1097/00002281-199711000-00002.CrossRefPubMed Reimers CD, Finkenstaedt M: Muscle imaging in inflammatory myopathies. Curr Opin Rheumatol. 1997, 9: 475-85. 10.1097/00002281-199711000-00002.CrossRefPubMed
16.
go back to reference Bemben MG: Use of diagnostic ultrasound for assessing muscle size. Journal of Strength and Conditioning Research. 2002, 16 (1): 103-8. 10.1519/1533-4287(2002)016<0103:UODUFA>2.0.CO;2.PubMed Bemben MG: Use of diagnostic ultrasound for assessing muscle size. Journal of Strength and Conditioning Research. 2002, 16 (1): 103-8. 10.1519/1533-4287(2002)016<0103:UODUFA>2.0.CO;2.PubMed
17.
go back to reference Perkin HM, Bond EA, Thompson J, Woods EC, Smith C: Realtime ultrasound: an objective measure of skeletal muscle. Physical Therapy Reviews. 2003, 8: 99-108. 10.1179/108331903225002506.CrossRef Perkin HM, Bond EA, Thompson J, Woods EC, Smith C: Realtime ultrasound: an objective measure of skeletal muscle. Physical Therapy Reviews. 2003, 8: 99-108. 10.1179/108331903225002506.CrossRef
18.
go back to reference Reeves ND, Maganaris CN, Narici MV: Ultrasonographic assessment of human skeletal muscle size. Eur J Appl Physiol. 2004, 91 (1): 116-8. 10.1007/s00421-003-0961-9.CrossRefPubMed Reeves ND, Maganaris CN, Narici MV: Ultrasonographic assessment of human skeletal muscle size. Eur J Appl Physiol. 2004, 91 (1): 116-8. 10.1007/s00421-003-0961-9.CrossRefPubMed
19.
go back to reference Wallwork TL, Hides JA, Stanton WR: Intrarater and interrater reliability of assessment of lumbar multifidus muscle thickness using rehabilitative ultrasound imaging. J Orthop Sports Phys Ther. 2007, 37 (10): 608-12.CrossRefPubMed Wallwork TL, Hides JA, Stanton WR: Intrarater and interrater reliability of assessment of lumbar multifidus muscle thickness using rehabilitative ultrasound imaging. J Orthop Sports Phys Ther. 2007, 37 (10): 608-12.CrossRefPubMed
20.
go back to reference Vohra PK, Kincaid BR, Japour CJ, Sobel E: Ultrasonographic evaluation of plantar fascia bands. A retrospective study of 211 symptomatic feet. J Am Podiatr Med Assoc. 2002, 92 (8): 444-9.CrossRefPubMed Vohra PK, Kincaid BR, Japour CJ, Sobel E: Ultrasonographic evaluation of plantar fascia bands. A retrospective study of 211 symptomatic feet. J Am Podiatr Med Assoc. 2002, 92 (8): 444-9.CrossRefPubMed
21.
go back to reference Huang Y-C, Wang L-Y, Wang H-C, Chang K-L, Leong C-P: The relationship between the flexible flatfoot and plantar fasciitis: ultrasonographic evaluation. Chang Gung Medical Journal. 2004, 27 (6): 443-8.PubMed Huang Y-C, Wang L-Y, Wang H-C, Chang K-L, Leong C-P: The relationship between the flexible flatfoot and plantar fasciitis: ultrasonographic evaluation. Chang Gung Medical Journal. 2004, 27 (6): 443-8.PubMed
22.
go back to reference Sarrafian SK, Topouzian LK: Anatomy and physiology of the extensor apparatus of the toes. J Bone Joint Surg Am. 1969, 51 (4): 669-79.PubMed Sarrafian SK, Topouzian LK: Anatomy and physiology of the extensor apparatus of the toes. J Bone Joint Surg Am. 1969, 51 (4): 669-79.PubMed
23.
go back to reference Garrow AP, Papgeorgiou A, Silman AJ, Thomas E, Jayson MIV, Macfarlane GJ: The grading of the hallux valgus, the Manchester Scale. J Am Podiatr Med Assoc. 2001, 91 (2): 74-8.CrossRefPubMed Garrow AP, Papgeorgiou A, Silman AJ, Thomas E, Jayson MIV, Macfarlane GJ: The grading of the hallux valgus, the Manchester Scale. J Am Podiatr Med Assoc. 2001, 91 (2): 74-8.CrossRefPubMed
24.
go back to reference Bruton A, Conway JH, Holgate ST: Reliability: what is it, and how is it measured?. Physiotherapy. 2000, 86 (2): 94-5. 10.1016/S0031-9406(05)61211-4.CrossRef Bruton A, Conway JH, Holgate ST: Reliability: what is it, and how is it measured?. Physiotherapy. 2000, 86 (2): 94-5. 10.1016/S0031-9406(05)61211-4.CrossRef
25.
go back to reference Rankin G, Stokes M: Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil. 1998, 12: 197-9. 10.1191/026921598672178340.CrossRef Rankin G, Stokes M: Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses. Clin Rehabil. 1998, 12: 197-9. 10.1191/026921598672178340.CrossRef
26.
go back to reference Bland J, Altman D: Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol. 2003, 22 (1): 85-93. 10.1002/uog.122.CrossRefPubMed Bland J, Altman D: Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol. 2003, 22 (1): 85-93. 10.1002/uog.122.CrossRefPubMed
27.
go back to reference Mantha S, Roizen M, Fleisher L, Thisted R, Foss J: Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis. Anesth Analg. 2000, 90: 593-602. 10.1097/00000539-200003000-00018.CrossRefPubMed Mantha S, Roizen M, Fleisher L, Thisted R, Foss J: Comparing Methods of Clinical Measurement: Reporting Standards for Bland and Altman Analysis. Anesth Analg. 2000, 90: 593-602. 10.1097/00000539-200003000-00018.CrossRefPubMed
28.
go back to reference Vincent WJ: Statistics in kinesiology. 1999, Leeds: Human Kinetics, Second Vincent WJ: Statistics in kinesiology. 1999, Leeds: Human Kinetics, Second
29.
go back to reference Eustace S, Williamson D, Wilson M, O'Byrne J, Bussolari L, Thomas M, Stephens M, Stack J, Weissman B: Tendon shift in hallux valgus: observations at MR imaging. Skeletal Radiol. 1996, 25: 519-24. 10.1007/s002560050128.CrossRefPubMed Eustace S, Williamson D, Wilson M, O'Byrne J, Bussolari L, Thomas M, Stephens M, Stack J, Weissman B: Tendon shift in hallux valgus: observations at MR imaging. Skeletal Radiol. 1996, 25: 519-24. 10.1007/s002560050128.CrossRefPubMed
30.
go back to reference Shima H, Okuda R, Kinoshita M, Yasuda T, Abe M: Hallux valgus with rupture of the abductor hallucis tendon: A report of two cases. Japan Journal of Orthopaedic Surgery & Traumatology. 2005, 48: 1089-90. Shima H, Okuda R, Kinoshita M, Yasuda T, Abe M: Hallux valgus with rupture of the abductor hallucis tendon: A report of two cases. Japan Journal of Orthopaedic Surgery & Traumatology. 2005, 48: 1089-90.
31.
go back to reference Sato T, Matsuzaki A, Arinaga M: Tarsal tunnel syndrome due to contracture of abductor hallucis. a case report. Orthopaedics & Traumatology. 2000, 49: 560-3.CrossRef Sato T, Matsuzaki A, Arinaga M: Tarsal tunnel syndrome due to contracture of abductor hallucis. a case report. Orthopaedics & Traumatology. 2000, 49: 560-3.CrossRef
32.
go back to reference Saggini R, Bellomo RG, Affaitati G, Lapenna D, Giamberardino MA: Sensory and Biomechanical Characterization of Two Painful Syndromes in the Heel. J Pain. 2006, 8: 215-22. 10.1016/j.jpain.2006.07.002.CrossRefPubMed Saggini R, Bellomo RG, Affaitati G, Lapenna D, Giamberardino MA: Sensory and Biomechanical Characterization of Two Painful Syndromes in the Heel. J Pain. 2006, 8: 215-22. 10.1016/j.jpain.2006.07.002.CrossRefPubMed
33.
go back to reference Moncayo M, Rudisch A, Kremser C, Moncayo M: 3D-MRI rendering of the anatomical structures related to acupuncture points of the Dai mai, Yin qiao mai and Yang qiao mai meridians within the context of the WOMED concept of lateral tension: implications for musculoskeletal disease. BMC Musculoskeletal Disorders. 2007, 8 (33): 1-7. Moncayo M, Rudisch A, Kremser C, Moncayo M: 3D-MRI rendering of the anatomical structures related to acupuncture points of the Dai mai, Yin qiao mai and Yang qiao mai meridians within the context of the WOMED concept of lateral tension: implications for musculoskeletal disease. BMC Musculoskeletal Disorders. 2007, 8 (33): 1-7.
34.
go back to reference Kiesela KB, Uhlb TL, Underwood FB, Rodd DW, Nitza AJ: Measurement of lumbar multifidus muscle contraction with rehabilitative ultrasound imaging. Manual Therapy. 2007, 12: 161-6. 10.1016/j.math.2006.06.011.CrossRef Kiesela KB, Uhlb TL, Underwood FB, Rodd DW, Nitza AJ: Measurement of lumbar multifidus muscle contraction with rehabilitative ultrasound imaging. Manual Therapy. 2007, 12: 161-6. 10.1016/j.math.2006.06.011.CrossRef
Metagegevens
Titel
Ultrasound evaluation of the abductor hallucis muscle: Reliability study
Auteurs
Alyse FM Cameron
Keith Rome
Wayne A Hing
Publicatiedatum
01-12-2008
Uitgeverij
BioMed Central
Gepubliceerd in
Journal of Foot and Ankle Research / Uitgave 1/2008
Elektronisch ISSN: 1757-1146
DOI
https://doi.org/10.1186/1757-1146-1-12

Andere artikelen Uitgave 1/2008

Journal of Foot and Ankle Research 1/2008 Naar de uitgave