Gepubliceerd in: Netherlands Heart Journal 1/2020

Open Access 01-08-2020 | Historical Review

The history of transcatheter aortic valve implantation: The role and contribution of an early believer and adopter, the Netherlands

Auteurs: P. de Jaegere, M. de Ronde, P. den Heijer, A. Weger, J. Baan

Gepubliceerd in: Netherlands Heart Journal | bijlage 1/2020

share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
insite
ZOEKEN

Abstract

This paper describes the history of transcatheter aortic valve implantation (TAVI) from its preclinical phase during which visionary pioneers developed its concept and prototype valves against strong head wind to first application in clinical practice (2002) and the clinical and scientific role of an early believer and adopter, the Netherlands (2005).
Dutch contribution to the field
  • First TAVI via the axillary artery, June 2006.
  • First true percutaneous TAVI, October 2006.
  • Contribution to TAVI using local anaesthesia.
  • Cerebral protection.

Introduction

2020 is the year that the Netherlands was to host the annual meeting of the European Society of Cardiology (ESC) whose mission is to reduce the burden of cardiovascular disease through education, congresses, surveys and publishing [1]. We as medical professionals as well as those who are directly or indirectly involved in the deterrence of illness or ailment and/or the delivering of care (e.g. healthcare authorities such as governments, controlling & advisory bodies, insurance companies, medical industry, etc.), should in addition to that statement also be inspired by the US Food and Drug Administration (FDA) that has taken the role and responsibility of ensuring the timely availability of innovative, safe and effective products to the American people [2].
Transcatheter aortic valve implantation (TAVI) is an example of such a technology that has proven to reduce disease burden by improving quality of life and survival in patients with aortic stenosis [39]. Because of its minimally invasive nature (local anaesthesia, minimal incision, beating heart procedure, no cardiopulmonary bypass, …) and its undeniable efficacy as it reduces valve stenosis, it has been embraced by physicians, patients and relatives. This enthusiasm is supported by the findings showing overall clinical equivalence between TAVI and surgical aortic valve replacement (SAVR) which necessitates general anaesthesia, extensive surgical trauma, cardiac arrest and cardiopulmonary bypass. TAVI is a disruptive technology and has caused a sea change in cardiovascular therapy similar to intracoronary stenting 40 years earlier [10].
At the cradle of TAVI are the visionary pioneers in Europe who came up with the idea and had the courage to introduce TAVI in clinical practice notwithstanding endless pessimism and even open opposition. Interestingly, the discussion of added clinical value and, thus, appropriateness of reimbursement is still present notwithstanding the consistent findings of the various randomised controlled trials and numerous multicentre surveys. This contrasts with the position of the FDA that has granted approval of TAVI in patients with aortic stenosis at low risk (August 2019). It also contrasts with the respected position of the Netherlands, which ranks fourth on the Global Innovation Index 2019 (after USA, Switzerland, and Sweden) and has been in the top ten of all countries in the world for many years [11]. It also ranks very highly in matters of social, economic and political stability, infrastructure and organisation and belongs to the elected group of high-income countries.

The early 1990s—Henning Andersen, Aarhus, Denmark

The TAVI story started in February 1989 when Henning Andersen—inspired by a lecture of Julio Palmaz on the development of coronary stents—thought of inserting a biological valve inside a large stent and to implant this using a balloon-expandable technique similar to the stent technique described by Palmaz. Andersen manufactured a stent himself with a diameter of 30 mm using metal wires that he bought in a hardware store in which he mounted a porcine aortic valve that was crimped onto a second-hand 30 mm balloon catheter pioneered by Cribier in the 1980s. The assembly was then inserted into a 41 Fr. introducer sheath (Fig. 1).
The first implantation on 1 May 1989 in an 80 kg pig was uneventful. Yet, during subsequent experiments coronary occlusion and valve embolisation occasionally occurred. He also found that arresting blood flow prevented balloon migration for which he developed a custom-made balloon-tipped catheter inflated in the common pulmonary trunk.
He presented his work on 19 May 1990 at the Danish Society of Cardiology (Odense, Denmark) but the abstract submitted to the 12th Congress of the ESC in 1990 (Stockholm, Sweden) was rejected. This also held for the paper submitted to the Journal of the American College of Cardiology (1990) and Circulation (1991). Both journals considered ‘it too low a priority for publication’. The paper was ultimately accepted by the European Heart Journal in 1992 (impact factor 1.6) followed by another publication in 1993 [12, 13]. Posters at the ESC and AHA meetings in 1992 received little attention.
Andersen realised that after 41 implantations and the submission of a patent (1993) he needed support from industry, engineering and funding to move forward. Yet, none showed interest as their medical advisers predominantly consisting of cardiothoracic surgeons provided numerous reasons why this could not work. As he could no longer afford the patent-related costs, he sought and received support from Stanford Surgical Technologies (SST), a small company founded by cardiothoracic surgeons in San Francisco, which licensed his patent with the promise to develop the technology. Yet, nothing happened. SST became Heartport and concentrated on the development of a less invasive SAVR (port access) while holding the exclusive license agreement. On 21 January 2001, Heartport was acquired by Johnson&Johnson-IS (JJ-IS) but three days earlier (18 January 2001) Heartport had sold the exclusive license agreement to Percutaneous Valve Technologies (PVT).

The balloon-expandable valve story—Alain Cribier, Martin Leon, Stan Rabinovich, Stanton Rowe (PVT)

In the mid-1990s Alain Cribier pioneered aortic balloon valvuloplasty (1985) but, confronted with the high restenosis rate, he presented a similar idea to a number of companies (Fig. 2). He knew that a balloon was capable of disrupting a stenotic aortic valve and decided to take advantage of the calcification for frame-anchoring. The first cadaver experiment was performed in 1994. The stent was conceptualised together with a cardiac surgeon (Dr Bessou) in such a way that in its crimped configuration (8 mm) it would be possible to deliver it via the femoral artery. Analogous to Andersen’s experience, companies were not interested as it was considered: ‘ridiculous, impossible and unnecessary’. Yet, Stanton Rowe championed the concept at JJ-IS, which licensed Cribier’s ideas and agreed to develop the percutaneous valve. Unfortunately, JJ-IS was at that time (1996) in the midst of acquiring Cordis and nothing happened. Cribier returned to Stanton Rowe and Stan Rabinovich who had both left JJ-IS. They brought Cribier’s idea back to Martin Leon which resulted in the creation of PVT (21 July 1999). In search of venture capital, they came into contact with an Israeli company ARAN R&D (June 1999, Jerusalem) who were interested in investing money but also in the development of the valve. Yet, the development of the percutaneous valve necessitated Andersen’s patents licensed to SST as they contained the fundamentals around a collapsible and expandable valve for which the PVT series A financing was used (December 2000). Despite negative advice from cardiothoracic surgeons, Medtronic and Boston Scientific subsequently became the main investors. A meeting between PVT and Edwards Lifesciences (TCT, September 2003) led to the acquisition of PVT (12 December 2003) after consent from Medtronic and Boston Scientific [14].
The first animal (non-atherosclerotic) experiments using polymeric valves were performed in August 2000 but without success since there was no anchoring. The choice of healthy animals is understandable but surprising given Cribier’s initial experiments with cadaver hearts. Noteworthy is the short time between the animal experiments and the first clinical TAVI (16 April 2002). Cribier was faced with a 57-year-old man in heart failure and a poor left ventricular ejection fraction (10%). To complicate matters, the patient had a failed aorto-bifemoral graft precluding a transfemoral approach for which the valve system was designed. At the risk of jeopardising all the work done, its future and the company the decision was taken to use the valve system via an ‘unplanned’ antegrade-transseptal route given the patient’s fate if nothing was done. In a subsequent feasibility study (36 patients, 2002–2005) the ‘success rate’ was 75% but paravalvular aortic regurgitation frequently occurred since only one size (23 mm) was available. During this study, the value of rapid ventricular pacing for valve delivery was recognised. Now, so many years after this pioneering work, Cribier says ‘… it is moving to remember the fierce opposition of experts towards this “totally unrealistic and stupid idea” that “would never work”’.

The self-expanding valve story—Georg Boertlein, Rob Michiels, Jacques Sequin (CoreValve)

CoreValve was founded by a cardiothoracic surgeon Jacques Seguin in Paris in 2001 together with a bio-medical engineer Georg Boertlein, who both understood the future of a catheter-based minimally invasive aortic valve treatment. In 2001, they found Rob Michiels (managing director of CONSILIUM associates active in identification, funding and green-housing of start-up technologies) immediately interested, which led to the entire high risk ‘seed round’ of CoreValve (mid-2002) and paved the way to the first-in-man in 2004 despite the fact that ‘… well-regarded medical professionals told them that we were crazy and it would be over their dead body if one of these ever got implanted in a patient’.
The CoreValve technology featured a novel leaflet and construction design using porcine pericardium to allow for more compression capability, thereby reducing catheter size and developing a true ‘interventional’ device. CoreValve chose a strategy of restricted use by a small number of centres in Europe that was continued after CE marking in 2007 for the 3th generation to assure successful maturing of their technology, appropriate training of physicians and to gather additional clinical data for post-approval surveillance later submission to the FDA.

TAVI in the Netherlands

The first TAVI in the Netherlands was performed in the Erasmus Medical Center, Rotterdam on 15 November 2005 using the self-expanding CoreValve (Fig. 3). [15] The team first conducted a short animal experiment to get a feel for the catheter system and technique of delivery (September 2005). The product was not CE-marked and, therefore, permission for compassionate use was granted by the Ministry of Health. Given the experimental nature and limited experience, a script was written in which all steps in chronological order were summarised including the materials and responsibility of each team member throughout the procedure (Fig. 4). This was continued during the early years of TAVI (2005–2007), which established a disciplined surgical-type approach in the intervention room that became an undisputable and natural modus operandi. Shortly after this, and in close cooperation with the Erasmus Medical Center, the second TAVI and first inclusion in the CoreValve first-in-man study was performed in the Amphia Hospital, Breda in February 2006 (Tab. 1).
Table 1
Summary start TAVI in the Netherlands
 
Year
Month
Day
Hospital
City
1
2005
11
15
Erasmus MC
Rotterdam
2
2006
2
9
Amphia
Breda
3
2007
6
8
St Antonius
Nieuwegein
4
2007
10
1
AMC
Amsterdam
5
2007
11
8
LUMC
Leiden
6
2008
4
10
UMCU
Utrecht
7
2008
11
26
MCL
Leeuwarden
8
2008
Catharina
Eindhoven
9
2008
Radboud
Nijmegen
10
2008
UMCM
Maastricht
11
2009
5
27
UMCG
Groningen
12
2009
10
15
OLVG
Amsterdam
13
2009
12
2
Isala
Zwolle
14
2012
11
13
MST
Enschede
15
2013
8
27
Haga
The Hague
16
2014
10
30
VUMC
Amsterdam
Population of the Netherlands (2018): 17.2 million (population density of 488 people/km2)
Gross domestic product/capita (2018): 53,228$
Hospital beds/1000 people: 5.8 (1990)–4.7 (2009). (USA 3.1 in 2009—source WHO)
At that time, some sort of circulatory support was recommended. In the first and the second patient (4 April 2006) an extracorporeal membrane oxygenation system was used but replaced by the TandemHeart in the next three as this allowed percutaneous insertion. It was also the period that an interventional radiologist experienced with percutaneous endovascular aortic repair (Lucas van Dijk) trained the team in echo-guided arterial access. This in combination with the use of a percutaneous closure device (Prostar) and the fact it turned out that TAVI could be performed without circulatory support (stable haemodynamics when reducing flow) led to the first fully percutaneous TAVI in the world (12 October 2006, Fig. 3). [16] A milestone that has been adopted world-wide and has become the standard for transfemoral TAVI (TF-TAVI). Of note, this was preceded by another first-in-the-world, namely TAVI via the subclavian artery on 30 June 2006 (Fig. 4), which has become the dominant approach in Radboud University Medical Center.
The next major step was the use of local anaesthesia. This was pioneered in the Netherlands by the team at the Academic Medical Center Amsterdam and first performed in 2010. It was the stepping stone for further simplification of TAVI to a minimalist approach mimicking PCI [17]. Moreover, TF-TAVI is now possible via a two-arterial access only (femoral artery for valve delivery and pacing over the wire, contralateral femoral or radial for pig-tale guidance) [18]. In case of TAVI for failed bioprosthesis, single access (femoral) suffices as the radiopaque structures of the bioprosthesis can be used as reference for valve deployment. During all those innovations, a fully percutaneous TAVI via the axillary artery under local anaesthesia became a reality and was first performed on 13 September 2011 (Fig. 5). In conjunction with the experience gained and improved catheter and valve technology, a program of early discharge was instituted [1821]. The Netherlands also played an important role in the adoption and evaluation of the use of cerebral protection devices for the prevention of perioperative stroke [22]. Last but not least and perhaps more importantly, the typical Dutch spirit of consultation and collaboration has led to structured multidisciplinary decision-making, planning, execution and evaluation involving medical specialists with various backgrounds and expertise ensuring balanced treatment stratification via the heart-team [23]. Given the outstanding infrastructure in the Netherlands, such as the nationwide prospective registry that was created under the auspices of the Netherlands Society of Cardiology and Cardio-Thoracic Surgery to improve quality of care by monitoring patient demographics and clinical outcomes (BHN-registratie), clinical programs are incorporated into clinical-scientific ones [24]. The TAVI Care and Cure is an example of this [25]. The clinical scientific output of the Netherlands is summarised in Tab. 2 and 3. Beyond the analysis of outcomes and the underlying mechanisms in single, multicentre national and international initiatives and collaborations, research has been initiated to elucidate and predict the interaction between the device and host as well as the role of Artificial Intelligence in TAVI [2635]. The clinical drive of innovation providing the best possible care to the individual patient and the scientific work (volume and content) of all Dutch medical professionals is an expression of the stimulating environment in which they have the pleasure to live and work.
Table 2
Peer-reviewed papers (source PubMED, EndNote X9) by Dutch investigators (as of 1 March 2020)
Year
n
≥15
≥10–15
0–10
2007
1
0
 
1
2008
3
  
3
2009
1
  
1
2010
15
1
1
13
2011
13
   
2012
18
2
1
15
2013
22
2
3
17
2014
36
5
  
2015
30
2
1
27
2016
33
2
1
30
2017
48
9
0
39
2018
48
6
0
42
2019
54
2
0
52
2020
24
2
0
22
Total number of publications (n) per year are subdivided by the journal Impact Factor (2019) using the following categories: ≥15, 10–15 and 0–10
Table 3
PhD theses by Dutch Academic Institutions
 
Year
Institute
1th Promotor
1th Copromotor
Candidate
Title
1
2011
EMC
Serruys
De Jaegere
Tzikas
The role of advanced imaging in TAVI
2
2011
EMC
Serruys
De Jaegere
Piazza
TAVI: from experiment to clinical practice and beyond
3
2012
AMC
Piek
Baan
Yong
Clinical and haemodynamic effects of TAVI
4
2013
EMC
De Jaegere
Van Domburg
Nuis
TAVI: Current results, insights & future challenges
5
2014
AMC
Piek
Baan
Van Dijk
Percutaneous treatment of heart valve disease
6
2014
EMC
De Jaegere
n.a.
Van Mieghem
Transcatheter aortic valve therapies: from cutting edge to mainstream
7
2014
EMC
De Jaegere
Van Domburg
Van der Boon
Insights into complications of TAVI
8
2014
LUMC
Bax
Delgado
Katsanos
Outcomes of TAVI
9
2014
UMCM
Prinzen
Van Gelder
Houthuizen
Left bundle branch block: controversies in aortic interventions and cardiac resynchronisation therapy
10
2014
UMCU
Doevendans
Stella
Samim
TAVI; optimisation of the technique, assessment of complications an future directions
11
2015
UMCU
Doevendans
Stella
Nijhoff
Evolving concepts in TAVI
12
2016
AMC
Piek
Baan
Wiegerinck
Replacing the valve, restoring flow. Effects of TAVI
13
2016
AMC
Van Bavel
Marquering
Elattar
Quantitative image analysis for planning of aortic valve replacement
14
2016
LUMC
Bax
Delgado
Ewe
Aortic valve disease: novel imaging insights from diagnosis to therapy
15
2018
AMC
Piek
Baan
Kesteren van
Screening complications and outcome of aortic valve implantation
16
2018
EMC
De Jaegere
Van Mieghem
Gils van
TAVI: insights and solutions for clinical complications and future perspectives
17
2018
UMCM
Prinzen
Houthuizen
Poels
Left bundle branch block in TAVI
18
2019
AMC
Piek
Delewi
Vlastra
Cerebral outcomes in patients undergoing TAVI
19
2019
AMC
De Winter
Tijssen
Abdelghani
Transcatheter interventions for structural heart disease: present and future
20
2019
AMC
Henriques
Vis
Van Mourik
Percutaneous treatment of aortic valve disease- Towards optimal patient outcomes
21
2019
EMC
Kappetein
Piazza
Mylotte
Evolution of transcatheter heart valve technology
22
2020
UMCU
Doevendans
Stella
Kooistra
Individualised optimisation of TAVI
23
2020
UMCU
Doevendans
Stella
Abawi
Role of novel predictive factors on clinical outcome after transcatheter aortic valve replacement
24
2020
EMC
Mattace Raso
Lenzen
Goudzwaard
The impact of frailty on outcome after TAVI in older patients
25
2020
EMC
De Jaegere
Lenzen
Faquir
Clinical application of patient-specific computer simulation and advanced imaging in TAVI

Acknowledgements

The authors express their respect and gratitude to Henning Andersen, Alain Cribier, Stan Rabinovich, Stanton Rowe and Rob Michels who kindly provided written testimonies of their pioneering work that they allowed us to use for this paper.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Onze productaanbevelingen

Netherlands Heart Journal

Het Netherlands Heart Journal wordt uitgegeven in samenwerking met de Nederlandse Vereniging voor Cardiologie en de Nederlandse Hartstichting. Het tijdschrift is Engelstalig en wordt gratis beschikbaa ...

Literatuur
2.
go back to reference Morrison TM, Pathmanathan P, Adwan M, Margerrison E. Advancing Regulatory Science With Computational Modeling for Medical Devices at the FDA’s Office of Science and Engineering Laboratories. Front Med. 2018;5:241–52.CrossRef Morrison TM, Pathmanathan P, Adwan M, Margerrison E. Advancing Regulatory Science With Computational Modeling for Medical Devices at the FDA’s Office of Science and Engineering Laboratories. Front Med. 2018;5:241–52.CrossRef
3.
go back to reference Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363:1597–607.CrossRef Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363:1597–607.CrossRef
4.
go back to reference Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011;364:2187–98.CrossRef Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011;364:2187–98.CrossRef
5.
go back to reference Leon MB, Smith CR, Mack MJ, et al. Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2016;374:1609–20.CrossRef Leon MB, Smith CR, Mack MJ, et al. Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2016;374:1609–20.CrossRef
6.
go back to reference Reardon MJ, Van Mieghem NM, Popma JJ, et al. Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2017;376:1321–31.CrossRef Reardon MJ, Van Mieghem NM, Popma JJ, et al. Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2017;376:1321–31.CrossRef
7.
go back to reference Thourani VH, Kodali S, Makkar RR, et al. Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis. Lancet. 2016;387:2218–25.CrossRef Thourani VH, Kodali S, Makkar RR, et al. Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis. Lancet. 2016;387:2218–25.CrossRef
8.
go back to reference Mack MJ, Thourani VH, Makkar R, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med. 2019;380:1695–705.CrossRef Mack MJ, Thourani VH, Makkar R, et al. Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients. N Engl J Med. 2019;380:1695–705.CrossRef
9.
go back to reference Popma JJ, Deeb MG, Yabukov SJ, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med. 2019;380:1706–15.CrossRef Popma JJ, Deeb MG, Yabukov SJ, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med. 2019;380:1706–15.CrossRef
10.
go back to reference Boskovski MT, Nguyen TC, McCabe JM, Kaneko T. Outcomes of Transcatheter Aortic Valve Replacement in Patients with Severe Aortic Stenosis: A Review of a Disruptive Technology in Aortic Valve Surgery. JAMA Surg. 2020;155(1):69-77.CrossRef Boskovski MT, Nguyen TC, McCabe JM, Kaneko T. Outcomes of Transcatheter Aortic Valve Replacement in Patients with Severe Aortic Stenosis: A Review of a Disruptive Technology in Aortic Valve Surgery. JAMA Surg. 2020;155(1):69-77.CrossRef
11.
go back to reference World Intellectual Property Organization at www.wipo_pub_gii_2019. World Intellectual Property Organization at www.wipo_pub_gii_2019.
12.
go back to reference Andersen HR, Knudsen LL, Hasenkam JM. Transluminal implantation of artificial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs. Eur Heart J. 1992;13:704–8.CrossRef Andersen HR, Knudsen LL, Hasenkam JM. Transluminal implantation of artificial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs. Eur Heart J. 1992;13:704–8.CrossRef
13.
go back to reference Knudsen LL, Andersen HR, Hasenkam M. Transluminal catheter implantation of a new expandable artificial heart valve in the descending aorta in isolated vessels and closed chest pigs. Int J Artif Organs. 1993;16:253–62.CrossRef Knudsen LL, Andersen HR, Hasenkam M. Transluminal catheter implantation of a new expandable artificial heart valve in the descending aorta in isolated vessels and closed chest pigs. Int J Artif Organs. 1993;16:253–62.CrossRef
15.
go back to reference de Jaegere PPT, Kappetein AP, Knook M, et al. Percutaneous aortic valve replacement in a patient who could not undergo surgical treatment. A case report with the CoreValve aortic valve prosthesis. EuroIntervention. 2006;1:475–9.PubMed de Jaegere PPT, Kappetein AP, Knook M, et al. Percutaneous aortic valve replacement in a patient who could not undergo surgical treatment. A case report with the CoreValve aortic valve prosthesis. EuroIntervention. 2006;1:475–9.PubMed
16.
go back to reference de Jaegere PPT, van Dijk LC, Laborde JC, et al. True percutaneous implantation of the CoreValve aortic valve prosthesis by the combined use of ultrasound guided vascular access, Prostar(R) XL and the TandemHeart(R). EuroIntervention. 2007;2:500–5.PubMed de Jaegere PPT, van Dijk LC, Laborde JC, et al. True percutaneous implantation of the CoreValve aortic valve prosthesis by the combined use of ultrasound guided vascular access, Prostar(R) XL and the TandemHeart(R). EuroIntervention. 2007;2:500–5.PubMed
17.
go back to reference De Jaegere PPT. How to move toward the least invasive transfemoral transcatheter aortic valve implantation procedure? Circ Cardiovasc Interv. 2014;7:439–40.CrossRef De Jaegere PPT. How to move toward the least invasive transfemoral transcatheter aortic valve implantation procedure? Circ Cardiovasc Interv. 2014;7:439–40.CrossRef
18.
go back to reference van Wiechen MP, Ooms JF, Hokken Th, et al. Point of view. Pathways: towards lean TAVI. Submitted. van Wiechen MP, Ooms JF, Hokken Th, et al. Point of view. Pathways: towards lean TAVI. Submitted.
19.
go back to reference Barbanti M, Baan J, Spence MS, et al. Feasibility and safety of early discharge after transfemoral transcatheter aortic valve implantation—rationale and design of the FAST-TAVI registry. BMC Cardiovasc Disord. 2017;17:259.CrossRef Barbanti M, Baan J, Spence MS, et al. Feasibility and safety of early discharge after transfemoral transcatheter aortic valve implantation—rationale and design of the FAST-TAVI registry. BMC Cardiovasc Disord. 2017;17:259.CrossRef
20.
go back to reference Vendrik J, Vlastra W, van Mourik MS, et al. Early mobilisation after transfemoral transcatheter aortic valve implantation: results of the MobiTAVI trial. Neth Heart J. 2020;28:240-8.CrossRefPubMedPubMedCentral Vendrik J, Vlastra W, van Mourik MS, et al. Early mobilisation after transfemoral transcatheter aortic valve implantation: results of the MobiTAVI trial. Neth Heart J. 2020;28:240-8.CrossRefPubMedPubMedCentral
21.
go back to reference Vendrik J, van Mourik M, Houterman S, Vis M, Baan J. Transkatheter aortaklepvervanging. Ned Tijdschr Geneeskd. 2019;163:d401. Vendrik J, van Mourik M, Houterman S, Vis M, Baan J. Transkatheter aortaklepvervanging. Ned Tijdschr Geneeskd. 2019;163:d401.
22.
go back to reference Van Mieghem NM, Schipper ME, Ladich E, et al. Histopathology of embolic debris captured during transcatheter aortic valve replacement. Circulation. 2013;127:2194–201.CrossRef Van Mieghem NM, Schipper ME, Ladich E, et al. Histopathology of embolic debris captured during transcatheter aortic valve replacement. Circulation. 2013;127:2194–201.CrossRef
23.
go back to reference de Jaegere PPT, de Weger A, den Heijer P, et al. Treatment decision for transcatheter aortic valve implantation: the role of the heart team : Position statement paper of the Dutch Working Group of Transcatheter Heart Interventions. Neth Heart J. 2020;28:229–39.CrossRef de Jaegere PPT, de Weger A, den Heijer P, et al. Treatment decision for transcatheter aortic valve implantation: the role of the heart team : Position statement paper of the Dutch Working Group of Transcatheter Heart Interventions. Neth Heart J. 2020;28:229–39.CrossRef
24.
go back to reference van Veghel , Daeter EJ, Bax M, et al. Organization of Outcome-Based Quality Improvement in Dutch Heart Centres. Eur Heart J Qual Care Clin Outcomes. 2020;6:49–54. van Veghel , Daeter EJ, Bax M, et al. Organization of Outcome-Based Quality Improvement in Dutch Heart Centres. Eur Heart J Qual Care Clin Outcomes. 2020;6:49–54.
25.
go back to reference De Ronde-Tillmans MJAG, Goudzwaard JA, El Faquir N, et al. TAVI Care and Cure, the Rotterdam multidisciplinary program for patients undergoing transcatheter aortic valve implantation: Design and rationale. Int J Cardiol. 2020;302:36–41.CrossRef De Ronde-Tillmans MJAG, Goudzwaard JA, El Faquir N, et al. TAVI Care and Cure, the Rotterdam multidisciplinary program for patients undergoing transcatheter aortic valve implantation: Design and rationale. Int J Cardiol. 2020;302:36–41.CrossRef
26.
go back to reference Schultz C, Rodriguez-Olivares R, Bosmans J, et al. Patient-specific image-based computer simulation for the prediction of valve morphology and calcium displacement after TAVI with the medtronic CoreValve and the Edwards SAPIEN valve. EuroIntervention. 2016;11:1044–52.CrossRef Schultz C, Rodriguez-Olivares R, Bosmans J, et al. Patient-specific image-based computer simulation for the prediction of valve morphology and calcium displacement after TAVI with the medtronic CoreValve and the Edwards SAPIEN valve. EuroIntervention. 2016;11:1044–52.CrossRef
27.
go back to reference de Jaegere P, De Santis G, Rodriguez-Olivares R, et al. Patient-specific computer modeling to predict aortic regurgitation after transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2016;9:508–12.CrossRef de Jaegere P, De Santis G, Rodriguez-Olivares R, et al. Patient-specific computer modeling to predict aortic regurgitation after transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2016;9:508–12.CrossRef
28.
go back to reference Rocatello G, El Faquir N, De Santis G, et al. Patient-Specific Computer Simulation to Elucidate the Role of Contact Pressure in the Development of New Conduction Abnormalities After Catheter-Based Implantation of a Self-Expanding Aortic Valve. Circ Cardiovasc Interv. 2018;11(2):e5344. Feb.CrossRef Rocatello G, El Faquir N, De Santis G, et al. Patient-Specific Computer Simulation to Elucidate the Role of Contact Pressure in the Development of New Conduction Abnormalities After Catheter-Based Implantation of a Self-Expanding Aortic Valve. Circ Cardiovasc Interv. 2018;11(2):e5344. Feb.CrossRef
29.
go back to reference Rocatello G, El Faquir N, de Backer O, et al. The Impact of Size and Position of a Mechanical Expandable Transcatheter Aortic Valve: Novel Insights Through Computational Modelling and Simulation. J Cardiovasc Transl Res. 2019;12:435–46.CrossRef Rocatello G, El Faquir N, de Backer O, et al. The Impact of Size and Position of a Mechanical Expandable Transcatheter Aortic Valve: Novel Insights Through Computational Modelling and Simulation. J Cardiovasc Transl Res. 2019;12:435–46.CrossRef
30.
go back to reference de Jaegere PPT, Rocatello G, Prendergast BD, de Backer O, Van Mieghem NM, Rajani R De. Patient-specific computer simulation for transcatheter cardiac interventions: what a clinician needs to know. Heart. 2019;105(Suppl 2):s21–s27. de Jaegere PPT, Rocatello G, Prendergast BD, de Backer O, Van Mieghem NM, Rajani R De. Patient-specific computer simulation for transcatheter cardiac interventions: what a clinician needs to know. Heart. 2019;105(Suppl 2):s21–s27.
31.
go back to reference Benjamins W, Hendriks T, Knuuti J, Juarez-Orozco JE, van der Harst P. A primer in artificial intelligence in cardiovascular medicine. Neth Heart J. 2019;27:392–402.CrossRef Benjamins W, Hendriks T, Knuuti J, Juarez-Orozco JE, van der Harst P. A primer in artificial intelligence in cardiovascular medicine. Neth Heart J. 2019;27:392–402.CrossRef
32.
go back to reference Siegersma R, Leiner T, Chew DP, Appelman Y, Hofstra L, Verjans JW. Artificial intelligence in cardiovascular imaging: state of the art and implications for the imaging cardiologist. Neth Heart J. 2019;27:403–13K.CrossRef Siegersma R, Leiner T, Chew DP, Appelman Y, Hofstra L, Verjans JW. Artificial intelligence in cardiovascular imaging: state of the art and implications for the imaging cardiologist. Neth Heart J. 2019;27:403–13K.CrossRef
33.
go back to reference Benjamins JW, van Leeuwen K, Hofstra L, et al. Enhancing cardiovascular artificial intelligence (AI) research in the Netherlands: CVON-AI consortium. Neth Heart J. 2019;27:414–25.CrossRef Benjamins JW, van Leeuwen K, Hofstra L, et al. Enhancing cardiovascular artificial intelligence (AI) research in the Netherlands: CVON-AI consortium. Neth Heart J. 2019;27:414–25.CrossRef
34.
go back to reference Lopes RR, van Mourik MS, Schaft EV, et al. Value of machine learning in predicting TAVI outcomes. Neth Heart J. 2019;27:443–50.CrossRef Lopes RR, van Mourik MS, Schaft EV, et al. Value of machine learning in predicting TAVI outcomes. Neth Heart J. 2019;27:443–50.CrossRef
Metagegevens
Titel
The history of transcatheter aortic valve implantation: The role and contribution of an early believer and adopter, the Netherlands
Auteurs
P. de Jaegere
M. de Ronde
P. den Heijer
A. Weger
J. Baan
Publicatiedatum
01-08-2020
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave bijlage 1/2020
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-020-01468-0

Andere artikelen bijlage 1/2020

Netherlands Heart Journal 1/2020 Naar de uitgave