TEE of transversal cross section of the descending aorta at the same level as depicted in Fig. 1a, showing the true and false aortic lumen. Slow rotating blood flow existed in the false lumen.
Opmerkingen

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1007/​s12471-017-1052-6) contains supplementary material, which is available to authorized users.
A 58-year-old male patient has a history of a Stanford type A aortic dissection running up to the left common iliac artery for which a composite aortic valve graft replacement was performed approximately three years ago. This time, the patient presented with fever and chills. We performed a transesophageal echocardiography (TEE), which excluded vegetations.
Upon retracting the TEE probe, the descending aorta showed two compartments (Fig. 1a) separated by a dissected intimal layer (Fig. 1a, arrow heads); the largest compartment is the false lumen (Fig. 1a, hash). Colour Doppler imaging showed laminar flow through the true aortic lumen (Fig. 1a, asterisk). In the false aortic lumen, slow rotating blood flow existed (online video). This phenomenon was not present more proximally in the descending aorta at the aortic arch (Fig. 1b). Residual blood flow may persist in the false lumen years after aortic dissection because of multiple fenestrations in the dissected intimal layer providing entry and exit locations for blood flow. In approximately 70% of patients with acute type A aortic dissection, the dissection extends beyond the ascending aorta [13]. After repair, these patients show an increased risk of developing post-dissection aortic aneurysm mainly through false lumen dilatation, requiring late distal aortic re-interventions in up to one-fifth of cases [3, 4]. False lumen patency appeared to be a major risk factor for late re-intervention and was associated with an accelerated annual growth rate [35]. Therefore, long-term follow-up and close surveillance of these patients are imperative.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

Netherlands Heart Journal

Het Netherlands Heart Journal wordt uitgegeven in samenwerking met de Nederlandse Vereniging voor Cardiologie en de Nederlandse Hartstichting. Het tijdschrift is Engelstalig en wordt gratis beschikbaa ...

Bijlagen

Caption Electronic Supplementary Material

TEE of transversal cross section of the descending aorta at the same level as depicted in Fig. 1a, showing the true and false aortic lumen. Slow rotating blood flow existed in the false lumen.
Literatuur
1.
go back to reference Conzelmann LO, Weigang E, Mehlhorn U, et al. Mortality in patients with acute aortic dissection type A: analysis of pre- and intraoperative risk factors from the German Registry for Acute Aortic Dissection Type A (GERAADA). Eur J Cardiothorac Surg. 2016;49:e44–52.CrossRefPubMed Conzelmann LO, Weigang E, Mehlhorn U, et al. Mortality in patients with acute aortic dissection type A: analysis of pre- and intraoperative risk factors from the German Registry for Acute Aortic Dissection Type A (GERAADA). Eur J Cardiothorac Surg. 2016;49:e44–52.CrossRefPubMed
2.
go back to reference Rylski B, Hahn N, Beyersdorf F, et al. Fate of the dissected aortic arch after ascending replacement in type A aortic dissection. Eur J Cardiothorac Surg. 2017;51:1127–34.CrossRefPubMed Rylski B, Hahn N, Beyersdorf F, et al. Fate of the dissected aortic arch after ascending replacement in type A aortic dissection. Eur J Cardiothorac Surg. 2017;51:1127–34.CrossRefPubMed
3.
go back to reference Kimura N, Tanaka M, Kawahito K, et al. Influence of patent false lumen on long-term outcome after surgery for acute type A aortic dissection. J Thorac Cardiovasc Surg. 2008;136:1160–6.CrossRefPubMed Kimura N, Tanaka M, Kawahito K, et al. Influence of patent false lumen on long-term outcome after surgery for acute type A aortic dissection. J Thorac Cardiovasc Surg. 2008;136:1160–6.CrossRefPubMed
4.
go back to reference Fattouch K, Sampognaro R, Navarra E, et al. Long-term results after repair of type A acute aortic dissection according to false lumen patency. Ann Thorac Surg. 2009;88:1244–50.CrossRefPubMed Fattouch K, Sampognaro R, Navarra E, et al. Long-term results after repair of type A acute aortic dissection according to false lumen patency. Ann Thorac Surg. 2009;88:1244–50.CrossRefPubMed
5.
go back to reference Halstead JC, Meier M, Etz C, et al. The fate of the distal aorta after repair of acute type A aortic dissection. J Thorac Cardiovasc Surg. 2007;133:127–35.CrossRefPubMed Halstead JC, Meier M, Etz C, et al. The fate of the distal aorta after repair of acute type A aortic dissection. J Thorac Cardiovasc Surg. 2007;133:127–35.CrossRefPubMed
Metagegevens
Titel
Residual flow in false lumen of chronic descending aortic dissection
Auteurs
M. Boulaksil
S. S. Liem
M. Akarkach
J. Timmermans
Publicatiedatum
09-11-2017
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 1/2018
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-017-1052-6

Andere artikelen Uitgave 1/2018

Netherlands Heart Journal 1/2018 Naar de uitgave

Image Puzzle - Answer

Total eclipse in the heart