Open Access 08-09-2020 | Letter to the Editor

Reply to the letter of Soliman et al. regarding ‘Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging’

Auteurs: N. H. M. Kooistra, M. Voskuil, P. R. Stella

Gepubliceerd in: Netherlands Heart Journal | Uitgave 10/2020

share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
insite
ZOEKEN
First of all we would like to thank Soliman et al. for their extensive reaction [1]. However, we believe there has been a misunderstanding concerning the purpose of the ELECT study results.
1.
As mentioned in the Background section of our article [2], the use of quantitative phase-contrast magnetic resonance imaging (MRI) as a tool to accurately assess the severity of aortic valve regurgitation (AR) was tested in a clinical setting. Although quantitative aortography with videodensitometric assessment is indeed also a promising tool to accurately assess AR, an important limitation of this technique compared to MRI is that quantitative aortography is less suitable for (non-invasive) follow-up. We also do not encourage the use of MRI for a day-to-day routine assessment after transcatheter aortic valve implantation (TAVI). However, we suggest that it could be used as a research tool in the assessment of AR in future TAVI studies. The use of MRI as a research tool could further improve the quality of valve comparison studies, since the tool used in daily practice for the assessment of AR, i.e. echocardiography, often results in a wide range of under- or over-estimation and has a huge range of inter-observer variability.
As stated in the Conclusion section: ‘Although the use of MRI to quantify AR is not feasible in daily clinical practice, it should be considered as a surrogate endpoint for clinical outcomes in comparative valve studies’.
 
2.
Indeed, one of the drawbacks of the study was the fact that pacemaker implantation after TAVI prevented the use of MRI in 7 patients. As described, the other 6 patients were excluded from MRI analysis due to pre-procedural implantation of a pacemaker, MRI flow measuring error, mortality or clinical instability.
 
Of the 13 patients that were excluded from MRI analyses, we did assess the severity of AR in 11 patients by performing a transthoracic echocardiogram (TTE). No TTE was performed in 2 patients of the self-expandable valve (SEV) group due to procedural mortality. The following AR rates were collected by TTE at discharge. In the balloon expandable valve (BEV) group (n = 6), 33% of patients had mild AR, and 67% had trace AR or none. In the SEV group (n = 5), 40% of patients had moderate AR, and 60% had trace AR or none. These AR results of the excluded patients assessed with TTE do not contradict the reported results of the MRI analysis. Therefore, the potential effect of selection bias due to exclusion of these patients from MRI examination on the reported results appears to be limited.
3.
The authors are right in their comment that atrial fibrillation reduces the accuracy of flow measurements on MRI. This is one of the limitations of MRI. The reported number of patients with atrial fibrillation at baseline included those with paroxysmal or chronic atrial fibrillation. The heart rhythm on ECG at discharge, which was measured close to the MRI examination, showed atrial fibrillation in 8 patients (5 BEV and 3 SEV). Indeed, the accuracy in these patients might have been reduced due to the atrial fibrillation.
 
4.
Finally, the comment on first-generation SEVs versus later-generation BEVs was mentioned in our Limitations section. To clarify: ‘at the time of study design and enrolment these valves were the only commercially available and most frequently used SEV/BEV’. The next-generation SEV was introduced more than 2 years after the start of study enrolment and at that time—mainly due to slow patient recruitment (mostly refusal to participate in the study)—the decision was made to stop enrolment rather than start a second-phase trial. However, it has also been shown that the use of the second-generation CoreValve Evolut is still complicated by a relatively high number of pacemaker implantations [3], which may negate the potential positive clinical effect of reduced AR with the newer design of this valve.
 
In general, owing to the nature of a device study design, where a comparison is made in daily use, the results will always be debated a couple of years later when new devices with an improved design have been made available. However, we strongly believe that making these differences clear it will stimulate researchers and companies to improve and further develop their products to achieve the highest standards possible at that particular point in time.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

Netherlands Heart Journal

Het Netherlands Heart Journal wordt uitgegeven in samenwerking met de Nederlandse Vereniging voor Cardiologie en de Nederlandse Hartstichting. Het tijdschrift is Engelstalig en wordt gratis beschikbaa ...

Literatuur
2.
go back to reference Kooistra NHM, Abawi M, Voskuil M, Urgel K, Samim M, Nijhoff F, et al. Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging. Neth Heart J. 2020;28(5):253–65.PubMedPubMedCentral Kooistra NHM, Abawi M, Voskuil M, Urgel K, Samim M, Nijhoff F, et al. Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging. Neth Heart J. 2020;28(5):253–65.PubMedPubMedCentral
3.
go back to reference Hellhammer K, Piayda K, Afzal S, Kleinebrecht L, Makosch M, Hennig I, et al. The latest evolution of the Medtronic CoreValve system in the era of transcatheter aortic valve replacement: matched comparison of the Evolut PRO and Evolut R. JACC Cardiovasc Interv. 2018;11:2314–22.PubMed Hellhammer K, Piayda K, Afzal S, Kleinebrecht L, Makosch M, Hennig I, et al. The latest evolution of the Medtronic CoreValve system in the era of transcatheter aortic valve replacement: matched comparison of the Evolut PRO and Evolut R. JACC Cardiovasc Interv. 2018;11:2314–22.PubMed
Metagegevens
Titel
Reply to the letter of Soliman et al. regarding ‘Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging’
Auteurs
N. H. M. Kooistra
M. Voskuil
P. R. Stella
Publicatiedatum
08-09-2020
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 10/2020
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-020-01488-w

Andere artikelen Uitgave 10/2020

Netherlands Heart Journal 10/2020 Naar de uitgave