Skip to main content
Top
Gepubliceerd in: Netherlands Heart Journal 5/2020

Open Access 03-04-2020 | Original Article

Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging

Auteurs: N. H. M. Kooistra, M. Abawi, M. Voskuil, K. Urgel, M. Samim, F. Nijhoff, H. M. Nathoe, P. A. F. M. Doevendans, S. A. J. Chamuleau, G. E. H. Leenders, T. Leiner, A. C. Abrahams, H. B. van der Worp, P. Agostoni, P. R. Stella

Gepubliceerd in: Netherlands Heart Journal | Uitgave 5/2020

share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
insite
ZOEKEN

Abstract

Introduction

Transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for inoperable, intermediate- or high-risk patients with severe symptomatic aortic stenosis and has been associated with excellent clinical outcomes. A clinically relevant remaining problem is aortic regurgitation (AR) post-TAVI, which is associated with increased mortality. Therefore, we conducted a prospective randomised trial to assess the safety and efficacy of a first-generation self-expandable valve (SEV; CoreValve) and a third-generation balloon-expandable valve (BEV; Sapien 3) with respect to clinical outcomes and AR as determined quantitatively by magnetic resonance imaging (MRI).

Methods

The ELECT study was an investigator-initiated, single-centre trial involving patients with severe symptomatic aortic stenosis and with a clinical indication for transfemoral TAVI. Fifty-six patients were randomly assigned to the BEV or SEV group.

Results

AR determined quantitatively by MRI was lower in the BEV than in the SEV group [regurgitant fraction: 1.1% (0–8.0) vs 8.7% (3.0–14.8) for SEV; p = 0.01]. Secondary endpoints according to the criteria of the Second Valve Academic Research Consortium (VARC-2) showed BEV to have better early safety [0 (0%) vs 8 (30%); p = 0.002] at 30 days and a lower risk of stroke [0 (0%) vs 5 (21%); p = 0.01], major adverse cardiac and cerebrovascular events [0 (0%) vs 10 (38%); p < 0.001] or death [0 (0%) vs 5 (19%); p = 0.02] in the 1st year compared with SEV.

Conclusions

The use of the latest generation of BEV was associated with less AR as quantitatively assessed by MRI. Although the use of MRI to quantify AR is not feasible in daily clinical practice, it should be considered as a surrogate endpoint for clinical outcomes in comparative studies of valves for TAVI.
ClinicalTrials.gov number NCT01982032.
What’s new?
  • We report on a randomised trial comparing the use of the latest-generation balloon-expandable valve and a first-generation self-expandable valve in patients undergoing transcatheter aortic valve implantation.
  • The severity of aortic regurgitation (AR) was quantitatively assessed by magnetic resonance imaging (MRI).
  • The latest-generation balloon-expandable valve was associated with less AR compared with the first-generation self-expandable valve.
  • Assessing AR quantitatively by MRI should be considered as a surrogate endpoint for clinical outcomes in comparative studies of valves for TAVI.

Background

Transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for inoperable, intermediate- or high-risk patients with severe symptomatic aortic stenosis and has been associated with excellent clinical outcomes [1, 2]. A remaining problem is post-TAVI aortic regurgitation (AR). Moderate or severe AR after TAVI is associated with an increased risk of mortality [3]. Therefore, reducing AR after TAVI remains an important target to optimise treatment. Wide ranges of AR rates have been reported, partly due to non-standardised and non-quantitative measurements [35], resulting in under-or overestimation of AR [68] as well as inter-observer variability. So far, quantitative phase-contrast magnetic resonance imaging (MRI) has proved to be the most accurate method for assessing AR and the best method to improve the understanding of the relation between AR severity and clinical outcomes [9, 10].
Over the past decade, several improvements to address AR have been introduced in different valves with different expansion systems. Two often-used systems are the self-expandable valve (SEV) by Medtronic (CoreValve, Medtronic, Minneapolis, MN, USA) and the balloon-expandable valve (BEV) by Edwards (Sapien 3, Edwards Lifesciences, Irvine, CA, USA). The latter has been specifically designed with the aim of reducing paravalvular AR by an additional outer skirt. Numerous studies have been published on the safety, efficacy and post-procedural AR of the SEV and the latest-generation BEV [1113]. To our knowledge, however, no randomised comparison between the two types of valve is available that investigates the differences in quantitatively measured AR and clinical outcomes.
Therefore, we conducted a prospective randomised trial to assess the safety and efficacy of the latest-generation BEV and first-generation SEV with respect to clinical outcomes, and AR as determined by MRI.

Methods

The study design and patient selection of the Edwards Sapien 3 periprosthetic leakage evaluation versus Medtronic CoreValve in transfemoral aortic valve implantation (ELECT) trial have been described previously [14]. Briefly, this study was an investigator-initiated, single-centre, prospective, two-arm randomised controlled trial comparing the latest-generation BEV (Sapien 3) and the first-generation SEV (CoreValve), with the intention of including 106 patients according to block randomisation. The CoreValve was chosen for comparison, because of its widespread use at the time the trial was initiated. The study was approved by the local ethics committee, in accordance with the ethical principles of the Declaration of Helsinki, and written informed consent was obtained from all patients.
Primary endpoint was severity of post-procedural AR, quantitatively assessed by MRI, performed 4–5 days after the index procedure. The severity of AR with respect to regurgitant fraction was graded according to previously published definitions: none/trace <8%, mild 9–20%, moderate 21–39% and severe >40% [15]. As these definitions were based on patients without a TAVI valve, the flow values used for the regurgitant fraction were measured at the level of the left ventricular outflow tract for the aortic outflow volume, and at the level of the aorta ascending for the regurgitant volume. The aim was to obtain the most reliable measurements for patients post-TAVI according to Kooistra et al. [16], whose study reported accurate quantification of AR by MRI velocity mapping in the presence of a prosthetic valve, when corrected for a systematic error and when the appropriate MRI slice position is used. Their findings were applied to the present study. For the regurgitant volume, a linear regression correction was applied [for Sapien 3: (measured flow −3.3823)/0.9634; for CoreValve: (measured flow −0.3903)/1.0392], to achieve most accurate AR results based on ex vivo phantom experiments [16]. The regurgitant fraction was calculated by aortic outflow volume/corrected aortic regurgitant volume × 100% offline using PACS (Sectra PACS, version 17.3, Sectra Workstations IDS7, Linköping, Sweden).
Secondary clinical endpoints at 30 days and 1 year have been described previously and were defined as per the Second Valve Academic Research Consortium (VARC-2) definitions [14, 17]. All patients were actively followed up for 1 year, and had clinical visits and transthoracic echocardiographic (TTE) evaluations at 6 months and 1 year. Quality of life was assessed on average 1 month before and 1 year after the index procedure by the Short-Form-36 and EuroQol visual analogue scale, and new cerebral lesions were measured by cerebral MRI (performed at day 4–5 after the index procedure).
All endpoints were analysed on an intention-to-treat basis. Continuous variables were presented as means ± standard deviation or medians (interquartile range) and compared using the two-sided unpaired Student t-test or Mann-Whitney U test, depending on data distribution. Categorical variables were presented as counts and percentages and compared using Fisher’s exact test. Time-to-event curves were constructed using Kaplan-Meier curves and compared with the log-rank test. The paired t-test, repeated-measures analysis of variance and Wilcoxon signed rank test were used to assess the change in effective regurgitant orifice area and mean aortic gradient over time between and within groups. The correlations between continuous and ordinal variables were assessed using Spearman’s correlation coefficient. Sample size calculation has been described previously [14]. In summary, the calculation yielded a sample size of 49 patients in each arm to detect a difference between BEV over SEV with respect to AR with a power of 80%.
All tests were two-sided, and a p-value of less than 0.05 was regarded to be statistically significant. Data were analysed using IBM SPSS Statistics software version 21 (IBM Corp., Armonk, NY, USA).

Results

Study cohort

In total, 56 patients were included and randomly assigned to receive either SEV (n = 27) or BEV (n = 29) between January 2014 and May 2016 (Fig. 1). Study enrolment was preliminary halted, due to the EU release of a new-generation SEV (Medtronic Evolut) and slow enrolment.
The groups were well balanced in terms of baseline characteristics (Tab. 1). All patients received the assigned TAVI device and were followed-up for 1 year (Fig. 1). In total, 13 patients were excluded from MRI analysis (7 post-procedural pacemaker implantation, 2 pre-procedural pacemaker, 1 flow measuring error, 2 mortality and 1 clinically unstable), and in 8 out of 43 patients MRI measurements were performed only at the level of the aorta ascending and therefore reported without a correction factor.
Table 1
Baseline characteristics
 
Number (%) of patientsa
 
 
Balloon-expandable
valve
(n = 29)
Self-expandable
valve
(n = 27)
p-value
Demographics
Age, years
77 ± 11
81 ± 7
0.32
Gender, female
15 (52)
13 (48)
1.00
BMI, kg/m2
28 ± 5
27 ± 5
0.31
Logistic EuroSCORE
13 ± 8
16 ± 10
0.43
NYHA III–IV
16 (55)
13 (48)
0.79
Coronary artery disease
17 (59)
10 (37)
0.12
Prior myocardial infarction
 7 (24)
 7 (26)
1.00
Prior CABG
 5 (17)
 3 (11)
0.71
Prior PCI
10 (35)
 9 (33)
1.00
Prior stroke
 5 (17)
 4 (15)
1.00
Estimated GFR, ml/min
65 ± 20
61 ± 23
0.54
Diabetes mellitus
 6 (21)
11 (41)
0.15
Hypertension
23 (79)
15 (56)
0.09
Dyslipidaemia
18 (62)
18 (67)
0.79
Peripheral artery disease
 3 (10)
 6 (22)
0.29
Atrial fibrillation
10 (34)
 7 (26)
0.57
Chronic pulmonary disease
 1 (3)
 7 (26)
0.02
Permanent pacemaker
 2 (7)
 0
0.49
QOL, EQ-VAS, mean (95% CI)
57 (48.8–65.7)
57 (49.6–65.2)
0.98
Transthoracic echocardiography
Aortic valve area, cm2
 0.72 ± 0.2
 0.75 ± 0.3
0.90
Mean gradient, mm Hg
42 ± 13
44 ± 20
0.80
Left ventricle ejection fraction, %
53 ± 10
51 ± 11
0.54
Regurgitation, moderate or severe
   
– Aortic
 4 (14)
 0
0.11
– Mitral
 3 (10)
 6 (23)
0.28
aPlus-minus values are mean ± SD
BMI body mass index, NYHA New York Heart Association, CABG coronary artery bypass grafting, PCI percutaneous coronary intervention, GFR glomerular filtration rate, QOL quality of life, IQR interquartile range, EQ-VAS EuroQol-visual analogue scale, CI confidence interval

Quantitative aortic regurgitation

The AR quantitatively measured by MRI was assessed in 43 patients (BEV: n = 23; SEV: n = 20) and showed a significant difference in favour of BEV for the regurgitant fraction [1.1% (0–8.0) vs 8.7% (3.0–14.8) for SEV; p = 0.01; Fig. 2]. After stratification into AR grades, this difference was not significant (p = 0.07; Fig. 2). With MRI we measured only the quantitative amount of regurgitation and not the origin; therefore, no distinction between valvular and paravalvular AR could be made for this modality.
The semi-quantitatively assessed severity of AR on TTE was still significantly lower in patients treated with the BEV at 1‑year follow-up (0% moderate, 14% mild, 86% none/trace for BEV vs 6% moderate, 38% mild, 56% none/trace for SEV; p = 0.04; Tab. 3). All AR appeared to be paravalvular on TTE.

Clinical outcomes at up to 1 year

Procedural characteristics are shown in Tab. 2. No significant intra-procedural differences were observed between the two groups, besides a shorter fluoroscopy time in the BEV group (18 ± 6 min vs 22 ± 9 min; p = 0.02).
Table 2
Procedural features
 
Number (%) of patientsa
 
 
Balloon-expandable
valve
(n = 29)
Self-expandable
valve
(n = 27)
p-value
General anaesthesia
  1 (3)
  0
 1.00
Pre-dilatation
 29 (100)
 26 (96)
 0.48
Valve size, mm
   
– 23
  7 (24)
  0
<0.001
– 26
 13 (45)
  4 (15)
– 29
  9 (31)
 18 (67)
– 31
  0
  5 (19)
Post-dilatation
  7 (24)
 12 (44)
 0.16
Valve malpositioning
  0
  1 (4)
 0.48
Implantation of ≥2 valves
  0
  1 (4)
 0.48
Fluoroscopic time, min
 18 ± 6
 22 ± 9
 0.02
Radiation, mGy
521 ± 279
664 ± 324
 0.07
Contrast volume, ml
163 ± 42
165 ± 40
 0.72
Intraprocedural mortality
  0
  2 (8)
 0.22
Device success (VARC-2)
 27 (93)
 21 (78)
 0.14
aPlus-minus values are mean ± SD
VARC‑2 Valve Academic Research Consortium‑2
At 30 days, there was a trend towards lower stroke rates among BEV patients compared with SEV patients [0 (0%) vs 3 (12%); p = 0.06; Tab. 3]. At 1 year, the difference in stroke rate between the groups had increased by 9% [BEV: 0 (0%) vs SEV: 5 (21%); p = 0.01; Tab. 3].
Table 3
Clinical outcome at 30 days and 1 year with balloon-expandable or self-expandable valve (intention-to-treat population)
 
30 days
 
1 year
 
 
Balloon-expandable
valve (n = 29)
N (%)
Self-expandable
valve (n = 27)
N (%)
p-value
Balloon-expandable
valve (n = 29)
N (%)
Self-expandable
valve (n = 27)
N (%)
p-value
Death
  0
  3 (11)
 0.07
 0
 5 (19)
 0.02
– Cardiovascular death
  0
  3 (11)
 0.07
 0
 5 (19)
 0.02
Repeat hospitalisation
  1 (3)
  2 (8)
 0.44
 2 (7)
 3 (13)
 0.44
– Valve re-intervention
  0
  0
 0
 0
 
Stroke or TIA
      
– All
  3 (10)
  3 (12)
 0.79
 3 (10)
 6 (25)
 0.19
– Stroke
  0
  3 (12)
 0.06
 0
 5 (21)
 0.01
 a. Ischaemic
  0
  3 (12)
 0.06
 0
 5 (21)
 0.01
 b. Bleeding
  0
  0
 
 0
 0
 
– TIA
  3 (10)
  0
 0.09
 3 (10)
 3 (15)
 0.82
AMI
  0
  0
 
 0
 0
 
Vascular complication
      
– Major
  0
  2 (7)
 0.14
 0
 3 (12)
 0.06
– Minor
  1 (3)
  1 (4)
 0.96
 1 (3)
 1 (4)
 0.96
Bleeding
      
– Life-threatening
  0
  2 (7)
 0.14
 0
 2 (7)
 0.14
– Major
  1 (3)
  1 (4)
 0.96
 2 (7)
 1 (4)
 0.64
– Minor
  1 (3)
  2 (7)
 0.49
 2 (7)
 2 (7)
 0.86
Pacemaker implantation
  5 (19)
  6 (24)
 0.61
 5 (19)
 7 (29)
 0.40
MACCE
  0
  7 (26)
 0.003
 0
10 (38)
<0.001
Early safety at 30 days
  0
  8 (30)
 0.002
   
In-hospital stay, days
  5 (5–6)
  6 (5–7)
 0.04
   
AKI in hospital
  2 (7)
  2 (8)
 1.00
   
– Stage 1
  2 (7)
  2 (8)
 1.00
   
– >Stage 1
  0
  0
    
Cerebral MRI lesions post-procedure
 19/23 (83)
 19/21(91)
 0.67
   
– Number per patient (IQR)
  3(1–6)
  4 (2.5–9)
 0.16
   
– Volume per patient mm3 (IQR)
235(37–701)
566(132–948)
 0.08
   
NYHA class improvement at 1 year
   
19 (68)
 7 (35)
 0.02
Aortic regurgitation on TTE
    
 0.04
– None/trace
  
24 (86)
 9 (56)
 
– Mild
  
 4 (14)
 6 (38)
 
– Moderate
  
 0
 1 (6)
 
– Severe
  
 0
 0
 
QOL, EQ-VAS
     
– Score, mean (95% CI)
  
71 (64.2–77.1)
68 (60.0–75.4)
0.54
Score change compared to baseline, mean (95% CI)
  
12 (3.3–21.2)
 7 (−2.2–15.7)
0.39
TIA transient ischaemic attack, AMI acute myocardial infarction, MACCE major adverse cardiac and cerebrovascular event, AKI acute kidney injury, MRI magnetic resonance imaging, IQR interquartile range, NYHA New York Heart Association, TTE transthoracic echocardiography, QOL quality of life, EQ-VAS EuroQol visual analogue scale, CI confidence interval
Binary events were calculated using Kaplan-Meier methods, and corresponding p-values using log-rank tests
The composite endpoint 30-day early safety according to the VARC‑2 criteria was significantly better for the BEV group [0 (0%) vs 8 (30%); p = 0.002], as well as MACCE at 30 days and length of hospital stay (Tab. 3; Fig. 3a). At 1 year, MACCE rate was still significant lower for the BEV group [0 (0%) vs 10 (38%); p < 0.001]. Furthermore, all-cause mortality was significantly lower in the BEV group at 1 year [0 (0%) vs 5 (19%); p = 0.02; Fig. 3a, c]. All deaths were due to cardiovascular causes: one peri-procedural tamponade, two cases of terminal heart failure, one type A aortic dissection in combination with a spondylodiscitis and a high suspicion of septic endocarditis, and one stroke within the 1 year of follow-up.
At 1 year, clinical New York Heart Association (NYHA) symptoms had improved more in BEV patients compared with the SEV group (Tab. 3). Aortic mean gradient differed at baseline, but was comparable between the groups at 1 year (Fig. 3b).
No significant correlation between NYHA class improvement and AR was found (Spearman’s correlation coefficient 0.3; p = 0.09).

Discussion

The ELECT trial is the first randomised controlled trial that compares quantitative AR as measured by MRI and clinical outcomes between the latest-generation balloon-expandable valve and a widely used first-generation self-expandable valve.
In this study, patients with a BEV had lower AR rates post-TAVI. Furthermore, clinical outcomes at 1 year showed a lower mortality rate, fewer strokes and MACCE, and a shorter hospital stay for the BEV group.
A distinguishing feature of the investigated latest-generation BEV to reduce post-TAVI AR is the additional skirt around the valve. Indeed, a lower AR rate for the new BEV was observed compared with the SEV. In recent studies of the latest-generation BEV, similar AR rates to those in our study have been reported (none/trace 56–74% [11, 12, 18]; moderate/severe 0–3.5% [11, 12, 18]). These AR rates are lower than those of the previous BEV generation (none/trace 29–66% [1921]; moderate/severe 5–23% [3, 1922]). The very low AR rates for BEV observed in the present study might reflect the effectiveness of the new skirt of this valve. Other potential factors influencing the reduced AR and complications might be the increased operator experience and the use of multi-detector computed tomography for adequate valve sizing.
The major strength of the present study is the fact that the AR severity was quantitatively assessed by MRI. A problem of previous studies is the wide range of AR rates, which are partly due to non-standardised and non-quantitative AR measurements that remain imprecise due to under- or overestimation of AR as well as inter-observer variability [4, 68]. Since MRI is currently considered to be the most accurate method available with low intra- and inter-observer variability and high accuracy, resulting in good reproducibility [9, 10, 16, 23, 24], the assessment and comparison of AR severity between the two valves has been assessed in this study as accurately as possible. The accuracy of AR is important, since AR is a frequent remaining problem that is associated with an increased 30-day and 1‑year mortality [3].
To investigate the association between quantitatively measured AR severity and clinical outcomes, NYHA class improvement was used, since the mortality rate was too low to study a correlation. No significant association was found in our study between AR severity and NYHA class improvement. This might be due to the low AR rates, with mostly none/trace or mild AR severity. However, this lack of association between mild AR and clinical outcomes is in accordance with the FRANCE‑2 Registry and the PARTNER II SAPIEN 3 trial [25, 26].
The secondary clinical endpoints of our randomised trial showed a significantly lower mortality rate at 1 year with no mortality at all in the BEV group. The mortality rate of 19% for the SEV group is in line with other studies of this first-generation valve [13, 19, 22, 27, 28]. The low mortality rate associated with the BEV might be explained by the reduction in complications that are associated with increased mortality, i.e. reduction in AR severity, strokes and life-threatening bleeding.
The striking low rates of stroke and life-threatening bleeding in the BEV group might be caused by many patient- or procedure-related factors. However, these could also be related to the low delivery profile (14 or 16 Fr), the lower crossing profile of the Sapien 3 system and a better distal flexion of the delivery catheter, resulting in fewer aortic arch injuries and life-threatening bleedings in patients receiving this latest-generation BEV. The overall low complication and mortality rates of the BEV are also reflected in the composite endpoints according to the VARC‑2 criteria, with a high device success rate, better early safety and a lower rate of MACCE. The observed difference in clinical outcomes between the SEV and BEV groups in our study might represent the difference in valve generation. Studies of the newer generations of the SEV have found lower complication rates, which are in line with the latest-generation BEV with a 1-year all-cause mortality rate and stroke rate around 8.5% and 3.5% respectively[29, 30].

Study limitations

The results of the clinical outcomes in the present study should be interpreted in the context of its small sample size and the lack of power to detect differences in endpoints—due to low recruitment—between the valves, resulting in wider confidence intervals and possible underestimation of differences. Nevertheless, the reported differences that were statistically significant can be considered to be a real difference and not a coincidence, since the statistical type I error (false-positive statistically significant result; α = 0.05) is not related to the power of a test. However, as stated by Button et al. [31], it is possible that the magnitude of the found effect is exaggerated due to the underpowered endpoint, which might explain the high stroke rate in the SEV group. Secondly, in this study, the first-generation CoreValve was used, which is nowadays not employed anymore. However, at the time the trial was initiated, these were the two most common valves used commercially.

Clinical implications and future perspectives

The results of this study show a high-quality comparison between two valve types regarding AR severity as quantitatively assessed by MRI. Although the use of MRI for the quantification of AR is not feasible in daily clinical practice due to its high costs, low availability and certain contra-indications (e.g. in patients with claustrophobia or < 6 weeks after implantation of pacemaker leads), it is of additive value as regards improving the accuracy and reproducibility of AR as well as reducing variability with respect to AR severity. In addition, studies with quantitative AR assessment are needed in order to improve the accuracy of AR estimation and to better understand the relationship between AR severity and clinical outcomes as well as differences between next-generation valves. Therefore, measuring AR by MRI should be considered in future studies comparing valves. Finally, this small study could be a preamble to a new randomised comparison between current-generation TAVI valves, but probably requires a larger sample size because of smaller differences in technical and clinical outcomes.

Conclusions

The use of latest-generation BEV was associated with less AR as quantitatively assessed by MRI. Although the use of MRI to quantify AR is not feasible in daily clinical practice, it should be considered as a surrogate endpoint for clinical outcomes in comparative studies of valves for TAVI.

Conflict of interest

N.H.M. Kooistra, M. Abawi, M. Voskuil, K. Urgel, M. Samim, F. Nijhoff, H.M. Nathoe, P.A.F.M. Doevendans, S.A.J. Chamuleau, G.E.H. Leenders, T. Leiner, A.C. Abrahams, H.B. van der Worp, P. Agostoni and P.R. Stella declare that they have no competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

Netherlands Heart Journal

Het Netherlands Heart Journal wordt uitgegeven in samenwerking met de Nederlandse Vereniging voor Cardiologie en de Nederlandse Hartstichting. Het tijdschrift is Engelstalig en wordt gratis beschikbaa ...

Bijlagen

Appendix

 
Table 4
Short Form (SF)-36 quality of life questionnaire results, with effect sizea per valve type
 
Baseline
 
1‑Year
 
 
Balloon-expandable valve
Self-expandable valve
 
Balloon-expandable valve
Self-expandable valve
 
 
Mean baseline
±SD (%)
Mean baseline
±SD (%)
p-value
Mean Change
Effect Size
Mean Change
Effect Size
p-value
General health
52.9 ± 19
46.7 ± 17
0.23
 5.0 ± 24
0.27
 5.3 ± 20
 0.31
0.97
Physical function
35.8 ± 28
36.1 ± 28
0.97
13.2 ± 25
0.47
 6.8 ± 19
 0.24
0.37
Vitality
51 ± 20
47.1 ± 23
0.54
 7.2 ± 24
0.36
 5.9 ± 20
 0.26
0.85
Physical role
23 ± 33
23.3 ± 37
0.98
16.7 ± 46
0.50
15.8 ± 50
 0.43
0.95
Mental health
66.6 ± 21
70 ± 16
0.54
 6.2 ± 20
0.30
 4.4 ± 16
 0.28
0.74
Bodily pain
71 ± 31
74.5 ± 25
0.64
10.9 ± 27
0.36
−3.2 ± 20
−0.13
0.07
Social function
59.7 ± 32
60.3 ± 29
0.95
 9.7 ± 34
0.31
10.6 ± 29
 0.36
0.94
Emotional role
47.6 ± 48
62 ± 47
0.28
13.6 ± 53
0.28
 7.3 ± 49
 0.15
0.70
a Effect sizes were calculated as the baseline score minus the 1‑year score, divided by the SD (standard deviation) of the baseline score
p-values represent the between valve comparisons
Literatuur
1.
go back to reference Mack MJ, Leon MB, Smith CR, Miller DC, Moses JW, Tuzcu EM, et al. 5‑year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial. Lancet. 2015;385(9986):2477–84.CrossRef Mack MJ, Leon MB, Smith CR, Miller DC, Moses JW, Tuzcu EM, et al. 5‑year outcomes of transcatheter aortic valve replacement or surgical aortic valve replacement for high surgical risk patients with aortic stenosis (PARTNER 1): a randomised controlled trial. Lancet. 2015;385(9986):2477–84.CrossRef
2.
go back to reference Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Søndergaard L, Mumtaz M, et al. Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2017;376(14):1321–31.CrossRef Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Søndergaard L, Mumtaz M, et al. Surgical or transcatheter aortic-valve replacement in intermediate-risk patients. N Engl J Med. 2017;376(14):1321–31.CrossRef
3.
go back to reference Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos P, Fraccaro C, et al. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61(15):1585–95.CrossRef Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos P, Fraccaro C, et al. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61(15):1585–95.CrossRef
4.
go back to reference Généreux P, Head SJ, Hahn R, Daneault B, Kodali S, Williams MR, et al. Paravalvular leak after transcatheter aortic valve replacement: the new achilles’ heel? A comprehensive review of the literature. J Am Coll Cardiol. 2013;61:1125–36.CrossRef Généreux P, Head SJ, Hahn R, Daneault B, Kodali S, Williams MR, et al. Paravalvular leak after transcatheter aortic valve replacement: the new achilles’ heel? A comprehensive review of the literature. J Am Coll Cardiol. 2013;61:1125–36.CrossRef
5.
go back to reference Abdelghani M, Soliman OII, Schultz C, Vahanian A, Serruys PW. Adjudicating paravalvular leaks of transcatheter aortic valves: a critical appraisal. Eur Heart J. 2016;37(34):2627–44.CrossRef Abdelghani M, Soliman OII, Schultz C, Vahanian A, Serruys PW. Adjudicating paravalvular leaks of transcatheter aortic valves: a critical appraisal. Eur Heart J. 2016;37(34):2627–44.CrossRef
6.
go back to reference Ribeiro HB, Le Ven F, Larose E, Dahou A, Nombela-Franco L, Urena M, et al. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation. Heart. 2014;100(24):1924–32.CrossRef Ribeiro HB, Le Ven F, Larose E, Dahou A, Nombela-Franco L, Urena M, et al. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment and quantification of aortic regurgitation in patients undergoing transcatheter aortic valve implantation. Heart. 2014;100(24):1924–32.CrossRef
7.
go back to reference Orwat S, Diller G‑P, Kaleschke G, Kerckhoff G, Kempny A, Radke RM, et al. Aortic regurgitation severity after transcatheter aortic valve implantation is underestimated by echocardiography compared with MRI. Heart. 2014;100(24):1933–8.CrossRef Orwat S, Diller G‑P, Kaleschke G, Kerckhoff G, Kempny A, Radke RM, et al. Aortic regurgitation severity after transcatheter aortic valve implantation is underestimated by echocardiography compared with MRI. Heart. 2014;100(24):1933–8.CrossRef
8.
go back to reference Salaun E, Jacquier A, Theron A, Giorgi R, Lambert M, Jaussaud N, et al. Value of CMR in quantification of paravalvular aortic regurgitation after TAVI. Eur Heart J Cardiovasc Imaging. 2016;17(1):41–50.PubMed Salaun E, Jacquier A, Theron A, Giorgi R, Lambert M, Jaussaud N, et al. Value of CMR in quantification of paravalvular aortic regurgitation after TAVI. Eur Heart J Cardiovasc Imaging. 2016;17(1):41–50.PubMed
9.
go back to reference Ribeiro HB, Orwat S, Hayek SS, Larose E, Babaliaros V, Dahou A, et al. Cardiovascular magnetic resonance to evaluate aortic regurgitation after transcatheter aortic valve replacement. J Am Coll Cardiol. 2016;68(6):577–85.CrossRef Ribeiro HB, Orwat S, Hayek SS, Larose E, Babaliaros V, Dahou A, et al. Cardiovascular magnetic resonance to evaluate aortic regurgitation after transcatheter aortic valve replacement. J Am Coll Cardiol. 2016;68(6):577–85.CrossRef
10.
go back to reference Lee JC, Branch KR, Hamilton-Craig C, Krieger EV. Evaluation of aortic regurgitation with cardiac magnetic resonance imaging: a systematic review. Heart. 2018;104(2):103–110. Lee JC, Branch KR, Hamilton-Craig C, Krieger EV. Evaluation of aortic regurgitation with cardiac magnetic resonance imaging: a systematic review. Heart. 2018;104(2):103–110.
11.
go back to reference Gonska B, Seeger J, Baarts J, Rodewald C, Scharnbeck D, Rottbauer W, et al. The balloon-expandable Edwards Sapien 3 valve is superior to the self-expanding Medtronic CoreValve in patients with severe aortic stenosis undergoing transfemoral aortic valve implantation. J Cardiol. 2017;69(6):877–82.CrossRef Gonska B, Seeger J, Baarts J, Rodewald C, Scharnbeck D, Rottbauer W, et al. The balloon-expandable Edwards Sapien 3 valve is superior to the self-expanding Medtronic CoreValve in patients with severe aortic stenosis undergoing transfemoral aortic valve implantation. J Cardiol. 2017;69(6):877–82.CrossRef
12.
go back to reference Webb J, Gerosa G, Lefèvre T, Leipsic J, Spence M, Thomas M, et al. Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve. J Am Coll Cardiol. 2014;64(21):2235–43.CrossRef Webb J, Gerosa G, Lefèvre T, Leipsic J, Spence M, Thomas M, et al. Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve. J Am Coll Cardiol. 2014;64(21):2235–43.CrossRef
13.
go back to reference Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb GM, et al. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med. 2014;370(19):1790–8.CrossRef Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb GM, et al. Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med. 2014;370(19):1790–8.CrossRef
14.
go back to reference Abawi M, Agostoni P, Kooistra NHM, Samim M, Nijhoff F, Voskuil M, et al. Rationale and design of the Edwards SAPIEN‑3 periprosthetic leakage evaluation versus Medtronic CoreValve in transfemoral aortic valve implantation (ELECT) trial. Neth Heart J. 2017;25(5):318–29.CrossRef Abawi M, Agostoni P, Kooistra NHM, Samim M, Nijhoff F, Voskuil M, et al. Rationale and design of the Edwards SAPIEN‑3 periprosthetic leakage evaluation versus Medtronic CoreValve in transfemoral aortic valve implantation (ELECT) trial. Neth Heart J. 2017;25(5):318–29.CrossRef
15.
go back to reference Gabriel RS, Renapurkar R, Bolen M, Verhaert D, Leiber M, Flamm SD, et al. Comparison of severity of aortic regurgitation by cardiovascular magnetic resonance versus transthoracic echocardiography. Am J Cardiol. 2011;108(7):1014–20.CrossRef Gabriel RS, Renapurkar R, Bolen M, Verhaert D, Leiber M, Flamm SD, et al. Comparison of severity of aortic regurgitation by cardiovascular magnetic resonance versus transthoracic echocardiography. Am J Cardiol. 2011;108(7):1014–20.CrossRef
16.
go back to reference Kooistra NHM, Nijhoff F, Abawi M, Agostoni P, Araya Roos DM, van Tuijl S, et al. Ex vivo pilot study of cardiac magnetic resonance velocity mapping for quantification of aortic regurgitation in a porcine model in the presence of a transcatheter heart valve. J Cardiovasc Transl Res. 2019;12(4):310–20.CrossRef Kooistra NHM, Nijhoff F, Abawi M, Agostoni P, Araya Roos DM, van Tuijl S, et al. Ex vivo pilot study of cardiac magnetic resonance velocity mapping for quantification of aortic regurgitation in a porcine model in the presence of a transcatheter heart valve. J Cardiovasc Transl Res. 2019;12(4):310–20.CrossRef
17.
go back to reference Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium‑2 consensus document. J Am Coll Cardiol. 2012;60(15):1438–54.CrossRef Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium‑2 consensus document. J Am Coll Cardiol. 2012;60(15):1438–54.CrossRef
18.
go back to reference Kodali S, Thourani VH, White J, Malaisrie SC, Lim S, Greason KL, et al. Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis. Eur Heart J. 2016;37(28):2252–62.CrossRef Kodali S, Thourani VH, White J, Malaisrie SC, Lim S, Greason KL, et al. Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis. Eur Heart J. 2016;37(28):2252–62.CrossRef
19.
go back to reference Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med. 2012;366(18):1705–15.CrossRef Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med. 2012;366(18):1705–15.CrossRef
20.
go back to reference Kodali S, Pibarot P, Douglas PS, Williams M, Xu K, Thourani V, et al. Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes. Eur Heart J. 2015;36(7):449–56.CrossRef Kodali S, Pibarot P, Douglas PS, Williams M, Xu K, Thourani V, et al. Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes. Eur Heart J. 2015;36(7):449–56.CrossRef
21.
go back to reference Schymik G, Lefèvre T, Bartorelli AL, Rubino P, Treede H, Walther T, et al. European experience with the second-generation Edwards SAPIEN XT transcatheter heart valve in patients with severe aortic stenosis: 1‑year outcomes from the SOURCE XT Registry. JACC Cardiovasc Interv. 2015;8(5):657–69.CrossRef Schymik G, Lefèvre T, Bartorelli AL, Rubino P, Treede H, Walther T, et al. European experience with the second-generation Edwards SAPIEN XT transcatheter heart valve in patients with severe aortic stenosis: 1‑year outcomes from the SOURCE XT Registry. JACC Cardiovasc Interv. 2015;8(5):657–69.CrossRef
22.
go back to reference Moat NE, Ludman P, De Belder M, Bridgewater B, Cunningham AD, Young CP, et al. Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: The U.K. TAVI (United Kingdom transcatheter aortic valve implantation) registry. J Am Coll Cardiol. 2011;58(20):2130–8.CrossRef Moat NE, Ludman P, De Belder M, Bridgewater B, Cunningham AD, Young CP, et al. Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: The U.K. TAVI (United Kingdom transcatheter aortic valve implantation) registry. J Am Coll Cardiol. 2011;58(20):2130–8.CrossRef
23.
go back to reference Dulce MC, Mostbeck GH, O’Sullivan M, Cheitlin M, Caputo GR, Higgins CB. Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging. Radiology. 1992;185(1):235–40.CrossRef Dulce MC, Mostbeck GH, O’Sullivan M, Cheitlin M, Caputo GR, Higgins CB. Severity of aortic regurgitation: interstudy reproducibility of measurements with velocity-encoded cine MR imaging. Radiology. 1992;185(1):235–40.CrossRef
24.
go back to reference Chatzimavroudis GP, Oshinski JN, Franch RH, Walker PG, Yoganathan AP, Pettigrew RI. Evaluation of the precision of magnetic resonance phase velocity mapping for blood flow measurements. J Cardiovasc Magn Reson. 2001;3(1):11–9.CrossRef Chatzimavroudis GP, Oshinski JN, Franch RH, Walker PG, Yoganathan AP, Pettigrew RI. Evaluation of the precision of magnetic resonance phase velocity mapping for blood flow measurements. J Cardiovasc Magn Reson. 2001;3(1):11–9.CrossRef
25.
go back to reference Van Belle E, Juthier F, Susen S, Vincentelli A, Iung B, Dallongeville J, et al. Postprocedural aortic regurgitation in balloon-expandable and self-expandable transcatheter aortic valve replacement procedures: analysis of predictors and impact on long-term mortality: insights from the FRANCE2 Registry. Circulation. 2014;129(13):1415–27.CrossRef Van Belle E, Juthier F, Susen S, Vincentelli A, Iung B, Dallongeville J, et al. Postprocedural aortic regurgitation in balloon-expandable and self-expandable transcatheter aortic valve replacement procedures: analysis of predictors and impact on long-term mortality: insights from the FRANCE2 Registry. Circulation. 2014;129(13):1415–27.CrossRef
26.
go back to reference Pibarot P, Hahn RT, Weissman NJ, Arsenault M, Beaudoin J, Bernier M, et al. Association of paravalvular regurgitation with 1‑year outcomes after transcatheter aortic valve replacement with the SAPIEN 3 valve. JAMA Cardiol. 2017;2(11):1208–16.CrossRef Pibarot P, Hahn RT, Weissman NJ, Arsenault M, Beaudoin J, Bernier M, et al. Association of paravalvular regurgitation with 1‑year outcomes after transcatheter aortic valve replacement with the SAPIEN 3 valve. JAMA Cardiol. 2017;2(11):1208–16.CrossRef
27.
go back to reference Abdel-Wahab M, Neumann FJ, Mehilli J, Frerker C, Richardt D, Landt M, et al. 1‑year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves: results from the CHOICE randomized clinical trial. J Am Coll Cardiol. 2015;66(7):791–800.CrossRef Abdel-Wahab M, Neumann FJ, Mehilli J, Frerker C, Richardt D, Landt M, et al. 1‑year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves: results from the CHOICE randomized clinical trial. J Am Coll Cardiol. 2015;66(7):791–800.CrossRef
28.
go back to reference Linke A, Wenaweser P, Gerckens U, Tamburino C, Bosmans J, Bleiziffer S, et al. Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study. Eur Heart J. 2014;35(38):2672–84.CrossRef Linke A, Wenaweser P, Gerckens U, Tamburino C, Bosmans J, Bleiziffer S, et al. Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study. Eur Heart J. 2014;35(38):2672–84.CrossRef
29.
go back to reference Manoharan G, Van Mieghem NM, Windecker S, Bosmans J, Bleiziffer S, Modine T. et al. 1‑Year outcomes with the Evolut R self-expanding transcatheter aortic valve: from the international FORWARD study. JACC Cardiovasc Interv. 2018;11(22):2326–34.CrossRef Manoharan G, Van Mieghem NM, Windecker S, Bosmans J, Bleiziffer S, Modine T. et al. 1‑Year outcomes with the Evolut R self-expanding transcatheter aortic valve: from the international FORWARD study. JACC Cardiovasc Interv. 2018;11(22):2326–34.CrossRef
30.
go back to reference Giannini C, De Carlo M, Tamburino C, Ettori F, Latib AM, Bedogni F, et al. Transcathether aortic valve implantation with the new repositionable self-expandable Evolut R versus CoreValve system: a case-matched comparison. Int J Cardiol. 2017;243:126–31.CrossRef Giannini C, De Carlo M, Tamburino C, Ettori F, Latib AM, Bedogni F, et al. Transcathether aortic valve implantation with the new repositionable self-expandable Evolut R versus CoreValve system: a case-matched comparison. Int J Cardiol. 2017;243:126–31.CrossRef
31.
go back to reference Button KS, Ioannidis JPA, Mokrysz C, Nosek BA, Flint J, Robinson ESJ, et al. Power failure: why small sample size undermines the reliability of neuroscience. Nat Rev Neurosci. 2013;14(5):365–76.CrossRef Button KS, Ioannidis JPA, Mokrysz C, Nosek BA, Flint J, Robinson ESJ, et al. Power failure: why small sample size undermines the reliability of neuroscience. Nat Rev Neurosci. 2013;14(5):365–76.CrossRef
Metagegevens
Titel
Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging
Auteurs
N. H. M. Kooistra
M. Abawi
M. Voskuil
K. Urgel
M. Samim
F. Nijhoff
H. M. Nathoe
P. A. F. M. Doevendans
S. A. J. Chamuleau
G. E. H. Leenders
T. Leiner
A. C. Abrahams
H. B. van der Worp
P. Agostoni
P. R. Stella
Publicatiedatum
03-04-2020
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 5/2020
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-020-01414-0

Andere artikelen Uitgave 5/2020

Netherlands Heart Journal 5/2020 Naar de uitgave