CC BY-NC-ND 4.0 · Indian J Plast Surg 2013; 46(03): 587-590
DOI: 10.4103/0970-0358.122028
Case Report
Association of Plastic Surgeons of India

Electrical burns of the abdomen

Rakesh Kumar Srivastava
Department of Burns & Plastic Surgery, Safdarjung Hospital, New Delhi, India
,
Ritesh Kumar
Department of Burns & Plastic Surgery, Safdarjung Hospital, New Delhi, India
› Author Affiliations
Further Information

Publication History

Publication Date:
07 October 2019 (online)

ABSTRACT

A 35-year-old male farmer came in contact with 11,000 volts high tension electric wire and sustained full thickness burn wounds over scapula, upper limb and anterior abdominal wall along with perforation of the intestine. Patient was initially managed conservatively in general surgery ward and was referred to us after 3 days with necrosis of the burned skin and muscles over the shoulder and abdomen. Patient was initially managed conservatively and then thorough debridement of the necrotic skin over the left shoulder and upper arm was done and the area was split skin grafted. Patient developed enterocutaneous fistula, which healed over a period of 8 weeks. The granulating wound over the abdomen was also skin grafted and patient was discharged after 18 days. About 4 months, after the discharge patient presented with ventral hernia. Repair of ventral hernia by synthetic mesh application and reconstruction of the abdominal wall with a free tensor fascia lata flap was done over the mesh, but the flap failed. Then after debridement two random pattern transposition skin flaps, one from the right upper and another from the left lower abdomen were transposed over the abdominal wound and donor area was skin grafted. Patient was discharged after 17 days.

 
  • 1 Dega S, Gnaneswar SG, Rao PR, Ramani P, Krishna DM. Electrical burn injuries. Some unusual clinical situations and management. Burns 2007;33:653-65.
  • 2 Miller FE, Peterson D, Miller J. Abdominal visceral perforation secondary to electrical injury: Case report and review of the literature. Burns Incl Therm Inj 1986;12:505-7.
  • 3 Yang JY, Tsai YC, Noordhoff MS. Electrical burn with visceral injury. Burns Incl Therm Inj 1985;11:207-12.
  • 4 Kumar P, Varma R. Immediate reconstruction of chest and abdominal wall defect following high voltage electrical injury. Burns 1994;20:557-9.
  • 5 Stone HH, Fabian TC, Turkleson ML, Jurkiewicz MJ. Management of acute full-thickness losses of the abdominal wall. Ann Surg 1981;193:612-8.