Abstract

Since recent studies have linked an impaired response to antiplatelet therapy with a higher incidence of atherothrombotic events, the monitoring of the efficacy of antiplatelet therapy in the individual patient has attracted much attention. In the present report, we demonstrate that platelet function testing with several point-of-care assays results in ambiguous and conflicting results: some assays indicated that the patient’s platelets were insufficiently inhibited by clopidogrel whereas other assays reported an adequate response. Therefore, platelet function assays should not be used solely to guide treatment decisions, and tailor-made antithrombotic treatment has to wait for the most predictive platelet function test to emerge for measuring the risk for thrombotic complications after stenting. Until then, daily clinical practice should not be guided by point-of-care platelet function testing. (Neth Heart J 2007;15:299-305).
Literatuur
go back to reference Cutlip DE, Baim DS, Ho KK, et al. Stent thrombosis in the modern era: a pooled analysis of multicenter coronary stent clinical trials. Circulation 2001;103:1967-71. Cutlip DE, Baim DS, Ho KK, et al. Stent thrombosis in the modern era: a pooled analysis of multicenter coronary stent clinical trials. Circulation 2001;103:1967-71.
go back to reference Iakovou I, Schmidt T, Bonizzoni E, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drugeluting stents. JAMA 2005;293:2126-30. Iakovou I, Schmidt T, Bonizzoni E, et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drugeluting stents. JAMA 2005;293:2126-30.
go back to reference Wenaweser P, Rey C, Eberli FR, et al. Stent thrombosis following bare-metal stent implantation: success of emergency percutaneous coronary intervention and predictors of adverse outcome. Eur Heart J 2005;26:1180-7. Wenaweser P, Rey C, Eberli FR, et al. Stent thrombosis following bare-metal stent implantation: success of emergency percutaneous coronary intervention and predictors of adverse outcome. Eur Heart J 2005;26:1180-7.
go back to reference Farb A, Burke AP, Kolodgie FD, Virmani R. Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 2003;108:1701-6. Farb A, Burke AP, Kolodgie FD, Virmani R. Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 2003;108:1701-6.
go back to reference Kuchulakanti PK, Chu WW, Torguson R, et al. Correlates and long-term outcomes of angiographically proven stent thrombosis with sirolimus- and paclitaxel-eluting stents. Circulation 2006; 113:1108-13. Kuchulakanti PK, Chu WW, Torguson R, et al. Correlates and long-term outcomes of angiographically proven stent thrombosis with sirolimus- and paclitaxel-eluting stents. Circulation 2006; 113:1108-13.
go back to reference Wenaweser P, Dorffler-Melly J, Imboden K, et al. Stent thrombosis is associated with an impaired response to antiplatelet therapy. J Am Coll Cardiol 2005;45:1748-52. Wenaweser P, Dorffler-Melly J, Imboden K, et al. Stent thrombosis is associated with an impaired response to antiplatelet therapy. J Am Coll Cardiol 2005;45:1748-52.
go back to reference Barragan P, Bouvier JL, Roquebert PO, et al. Resistance to thienopyridines: clinical detection of coronary stent thrombosis by monitoring of vasodilator-stimulated phosphoprotein phosphorylation. Catheter Cardiovasc Interv 2003;59:295-302. Barragan P, Bouvier JL, Roquebert PO, et al. Resistance to thienopyridines: clinical detection of coronary stent thrombosis by monitoring of vasodilator-stimulated phosphoprotein phosphorylation. Catheter Cardiovasc Interv 2003;59:295-302.
go back to reference Matetzky S, Shenkman B, Guetta V, et al. Clopidogrel resistance is associated with increased risk of recurrent atherothrombotic events in patients with acute myocardial infarction. Circulation 2004;109:3171-5. Matetzky S, Shenkman B, Guetta V, et al. Clopidogrel resistance is associated with increased risk of recurrent atherothrombotic events in patients with acute myocardial infarction. Circulation 2004;109:3171-5.
go back to reference van Werkum JW, Heestermans AACM, Deneer VHM, Hackeng CM, Ten Berg JM. Clopidogrel resistance: Fact and Fiction. Future Cardiology 2006;2:215-28. van Werkum JW, Heestermans AACM, Deneer VHM, Hackeng CM, Ten Berg JM. Clopidogrel resistance: Fact and Fiction. Future Cardiology 2006;2:215-28.
go back to reference Serebruany VL, Steinhubl SR, Berger PB, Malinin AI, Bhatt DL, Topol EJ. Variability in platelet responsiveness to clopidogrel among 544 individuals. J Am Coll Cardiol 2005;45:246-51. Serebruany VL, Steinhubl SR, Berger PB, Malinin AI, Bhatt DL, Topol EJ. Variability in platelet responsiveness to clopidogrel among 544 individuals. J Am Coll Cardiol 2005;45:246-51.
go back to reference Jaremo P, Lindahl TL, Fransson SG, Richter A. Individual variations of platelet inhibition after loading doses of clopidogrel. J Intern Med 2002;252:233-8. Jaremo P, Lindahl TL, Fransson SG, Richter A. Individual variations of platelet inhibition after loading doses of clopidogrel. J Intern Med 2002;252:233-8.
go back to reference Gurbel PA, Bliden KP, Hiatt BL, O’Connor CM. Clopidogrel for coronary stenting: response variability, drug resistance, and the effect of pretreatment platelet reactivity. Circulation 2003;107:2908-13. Gurbel PA, Bliden KP, Hiatt BL, O’Connor CM. Clopidogrel for coronary stenting: response variability, drug resistance, and the effect of pretreatment platelet reactivity. Circulation 2003;107:2908-13.
go back to reference Cuisset T, Frere C, Quilici J, et al. Benefit of a 600-mg loading dose of clopidogrel on platelet reactivity and clinical outcomes in patients with non-ST-segment elevation acute coronary syndrome undergoing coronary stenting. J Am Coll Cardiol 2006;48:1339-45. Cuisset T, Frere C, Quilici J, et al. Benefit of a 600-mg loading dose of clopidogrel on platelet reactivity and clinical outcomes in patients with non-ST-segment elevation acute coronary syndrome undergoing coronary stenting. J Am Coll Cardiol 2006;48:1339-45.
go back to reference Geisler T, Langer H, Wydymus M, et al. Low response to clopidogrel is associated with cardiovascular outcome after coronary stent implantation. Eur Heart J 2006;27:2420-5. Geisler T, Langer H, Wydymus M, et al. Low response to clopidogrel is associated with cardiovascular outcome after coronary stent implantation. Eur Heart J 2006;27:2420-5.
go back to reference Gurbel PA, Bliden KP, Guyer K, et al. Platelet reactivity in patients and recurrent events post-stenting: results of the PREPARE POSTSTENTING Study. J Am Coll Cardiol 2005;46:1820-6. Gurbel PA, Bliden KP, Guyer K, et al. Platelet reactivity in patients and recurrent events post-stenting: results of the PREPARE POSTSTENTING Study. J Am Coll Cardiol 2005;46:1820-6.
go back to reference Steinhubl SR. The VerifyNow system. In: Michelson AD (ed). Platelets. 2nd ed. San Diego, CA: Elsevier/Academic Press, 2006. Steinhubl SR. The VerifyNow system. In: Michelson AD (ed). Platelets. 2nd ed. San Diego, CA: Elsevier/Academic Press, 2006.
go back to reference van Werkum JW, van der Stelt CA, Seesing TH, Hackeng CM, Ten Berg JM. A head-to-head comparison between the VerifyNowP2Y12-assay and light transmittance aggregometry for monitoring the individual platelet response to clopidogrel in patients undergoing elective PCI. J Thromb Haemost 2006;4:2516-8. van Werkum JW, van der Stelt CA, Seesing TH, Hackeng CM, Ten Berg JM. A head-to-head comparison between the VerifyNowP2Y12-assay and light transmittance aggregometry for monitoring the individual platelet response to clopidogrel in patients undergoing elective PCI. J Thromb Haemost 2006;4:2516-8.
go back to reference Savion N, Varon D. Impact—the cone and plate(let) analyzer: testing platelet function and anti-platelet drug response. Pathophysiol Haemost Thromb 2006;35:83-8. Savion N, Varon D. Impact—the cone and plate(let) analyzer: testing platelet function and anti-platelet drug response. Pathophysiol Haemost Thromb 2006;35:83-8.
go back to reference Mammen EF, Comp PC, Gosselin R, et al. PFA-100 system: a new method for assessment of platelet dysfunction. Semin Thromb Hemost 1998;24:195-202. Mammen EF, Comp PC, Gosselin R, et al. PFA-100 system: a new method for assessment of platelet dysfunction. Semin Thromb Hemost 1998;24:195-202.
go back to reference White MM, Krishnan R, Kueter TJ, Jacoski MV, Jennings LK. The use of the point of care Helena ICHOR/Plateletworks and the Accumetrics Ultegra RPFA for assessment of platelet function with GPIIB-IIIa antagonists. J Thromb Thrombolysis 2004;18:163-9. White MM, Krishnan R, Kueter TJ, Jacoski MV, Jennings LK. The use of the point of care Helena ICHOR/Plateletworks and the Accumetrics Ultegra RPFA for assessment of platelet function with GPIIB-IIIa antagonists. J Thromb Thrombolysis 2004;18:163-9.
go back to reference Ivandic BT, Schlick P, Staritz P, Kurz K, Katus HA, Giannitsis E. Determination of Clopidogrel Resistance by Whole Blood Platelet Aggregometry and Inhibitors of the P2Y12 Receptor. Clin Chem 2006;52:383-8. Ivandic BT, Schlick P, Staritz P, Kurz K, Katus HA, Giannitsis E. Determination of Clopidogrel Resistance by Whole Blood Platelet Aggregometry and Inhibitors of the P2Y12 Receptor. Clin Chem 2006;52:383-8.
go back to reference Chen WH, Lee PY, Ng W, Tse HF, Lau CP. Aspirin resistance is associated with a high incidence of myonecrosis after non-urgent percutaneous coronary intervention despite clopidogrel pretreatment. J Am Coll Cardiol 2004;43:1122-6. Chen WH, Lee PY, Ng W, Tse HF, Lau CP. Aspirin resistance is associated with a high incidence of myonecrosis after non-urgent percutaneous coronary intervention despite clopidogrel pretreatment. J Am Coll Cardiol 2004;43:1122-6.
go back to reference Steinhubl SR, Talley JD, Braden GA, et al. Point-of-care measured platelet inhibition correlates with a reduced risk of an adverse cardiac event after percutaneous coronary intervention: results of the GOLD (AU-Assessing Ultegra) multicenter study. Circulation 2001;103:2572-8. Steinhubl SR, Talley JD, Braden GA, et al. Point-of-care measured platelet inhibition correlates with a reduced risk of an adverse cardiac event after percutaneous coronary intervention: results of the GOLD (AU-Assessing Ultegra) multicenter study. Circulation 2001;103:2572-8.
go back to reference Lakkis NM, George S, Thomas E, Ali M, Guyer K, Carville D. Use of ICHOR-platelet works to assess platelet function in patients treated with GP IIb/IIIa inhibitors. Catheter Cardiovasc Interv 2001;53:346-51. Lakkis NM, George S, Thomas E, Ali M, Guyer K, Carville D. Use of ICHOR-platelet works to assess platelet function in patients treated with GP IIb/IIIa inhibitors. Catheter Cardiovasc Interv 2001;53:346-51.
go back to reference Golanski J, Pluta J, Baraniak J, Watala C. Limited usefulness of the PFA-100 for the monitoring of ADP receptor antagonists–in vitro experience. Clin Chem Lab Med 2004;42:25-9. Golanski J, Pluta J, Baraniak J, Watala C. Limited usefulness of the PFA-100 for the monitoring of ADP receptor antagonists–in vitro experience. Clin Chem Lab Med 2004;42:25-9.
Metagegevens
Titel
Point-of-care platelet function testing in patients undergoing PCI: between a rock and a hard place
Auteurs
J. W. van Werkum
C. M. Hackeng
F. I. de Korte
F. W. A. Verheugt
J. M. ten Berg
Publicatiedatum
01-09-2007
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 9/2007
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/BF03086004