Open Access 01-04-2014 | Meeting abstract

Plantar pressure distribution during treadmill walking in comfort shoes with PLA(Poly Lactic Acid) resins

Auteurs: Seung-Bum Park, Kyung-Deuk Lee, Dae-Woong Kim, Jung-Hyeon Yoo, Kyung-Hun Kim

Gepubliceerd in: Journal of Foot and Ankle Research | bijlage 1/2014

share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
insite
ZOEKEN
In the framework of environmentally friendly processes and products, poly lactic acid(PLA) represents the best polymeric substitutes for various petropolymers because of its renewability, biodegradability, biocompatibility and good thermomechanical properties [1]. The purpose of this study was to analyze foot pressure distribution of PLA materials in functional shoes. Comfort is an important aspect in footwear. Footwear comfort has an influence on injury [2, 3]. The development of new materials is considered as the important point for manufacturing functional shoes [4].
Ten healthy female(mean height: 159.8 cm, mean body mass: 54.8 kg, mean age 20.8 yrs.) participated in this study. All subjects were free of lower extremity pain, history of serious injuries or operative treatment, or subjective symptoms interfering with walking.
The subjects were required to walking(3.2km/h) for treadmill. Each subject wore two different shoes, type A(PLA) and Type B(control)(figure 1) during walking. The PEDAR®-X insole system(Novel GmbH, Germany) was used to measure the foot pressure and force. Pressure distribution data(contact areas, maximum force, peak pressure, maximum mean pressure) was collected with pressure device at a sampling rate of 100Hz. The feet were divided into four regions: foot(Total), forefoot, midfoot, rearfoot.
Results of foot pressure distribution date show that(figure 2) contact area increased by 4% in the type A compared to type B, Also, maximum mean pressure decreased by 5%. However, peak force increased by 6%, and peak pressure increased by 5% as well. AS a result PLA resins may be helpful in decreasing overall pressure in foot therefore provide better comfort in foot.
This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://​creativecommons.​org/​licenses/​by/​4.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

BSL Podotherapeut Totaal

Binnen de bundel kunt u gebruik maken van boeken, tijdschriften, e-learnings, web-tv's en uitlegvideo's. BSL Podotherapeut Totaal is overal toegankelijk; via uw PC, tablet of smartphone.

Literatuur
1.
go back to reference Jean-Marie R, Youssef H, Marius M, Philippe D: Polylactide (PLA)-based nanocomposites. Progress in Polymer Science. 2013, 38 (10-11): 1504-1542. 10.1016/j.progpolymsci.2013.05.014.CrossRef Jean-Marie R, Youssef H, Marius M, Philippe D: Polylactide (PLA)-based nanocomposites. Progress in Polymer Science. 2013, 38 (10-11): 1504-1542. 10.1016/j.progpolymsci.2013.05.014.CrossRef
2.
go back to reference Nigg BM, Hintzen S, Ferber R: Effect of an unstable shoe construction on lower extremity gait characteristics. Clinical Biomechanics. 2006, 21 (1): 82-88. 10.1016/j.clinbiomech.2005.08.013.CrossRefPubMed Nigg BM, Hintzen S, Ferber R: Effect of an unstable shoe construction on lower extremity gait characteristics. Clinical Biomechanics. 2006, 21 (1): 82-88. 10.1016/j.clinbiomech.2005.08.013.CrossRefPubMed
3.
go back to reference Ramanathan AK, Kiran P, Arnold GP, Wang W, Abboud RJ: Repeatability of the Pedar-X in-shoe pressure measuring system. Foot and Ankle Surgery. 2010, 16: 70-73. 10.1016/j.fas.2009.05.006.CrossRefPubMed Ramanathan AK, Kiran P, Arnold GP, Wang W, Abboud RJ: Repeatability of the Pedar-X in-shoe pressure measuring system. Foot and Ankle Surgery. 2010, 16: 70-73. 10.1016/j.fas.2009.05.006.CrossRefPubMed
4.
go back to reference Kim EH, Cho HK, Jung TW, Kim SS, Chung JW: The Biomechanical Evaluation of Functional Insoles. Korean Journal of Sport Biomechanics. 2010, 20 (3): 345-353. 10.5103/KJSB.2010.20.3.345.CrossRef Kim EH, Cho HK, Jung TW, Kim SS, Chung JW: The Biomechanical Evaluation of Functional Insoles. Korean Journal of Sport Biomechanics. 2010, 20 (3): 345-353. 10.5103/KJSB.2010.20.3.345.CrossRef
Metagegevens
Titel
Plantar pressure distribution during treadmill walking in comfort shoes with PLA(Poly Lactic Acid) resins
Auteurs
Seung-Bum Park
Kyung-Deuk Lee
Dae-Woong Kim
Jung-Hyeon Yoo
Kyung-Hun Kim
Publicatiedatum
01-04-2014
Uitgeverij
BioMed Central
Gepubliceerd in
Journal of Foot and Ankle Research / Uitgave bijlage 1/2014
Elektronisch ISSN: 1757-1146
DOI
https://doi.org/10.1186/1757-1146-7-S1-A123

Andere artikelen bijlage 1/2014

Journal of Foot and Ankle Research 1/2014 Naar de uitgave