TODO: Skip to main content
Top
Gepubliceerd in:

09-11-2019

Optimizing measurement of vision-related quality of life: a computerized adaptive test for the impact of vision impairment questionnaire (IVI-CAT)

Auteurs: Eva K. Fenwick, Bao Sheng Loe, Jyoti Khadka, Ryan E. K. Man, Gwyn Rees, Ecosse L. Lamoureux

Gepubliceerd in: Quality of Life Research | Uitgave 3/2020

Log in om toegang te krijgen
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Abstract

Purpose

To compare the results from a simulated computerized adaptive test (CAT) for the 28-item Impact of Vision Impairment (IVI) questionnaire and the original paper–pencil version in terms of efficiency (main outcome), defined as percentage item reduction.

Methods

Using paper–pencil IVI data from 832 participants across the spectrum of vision impairment, item calibrations of the 28-item IVI instrument and its associated 20-item vision-specific functioning (VSF) and 8-item emotional well-being (EWB) subscales were generated with Rasch analysis. Based on these calibrations, CAT simulations were conducted on 1000 cases, with ‘high’ and ‘moderate’ precision stopping rules (standard error of measurement [SEM] 0.387 and 0.521, respectively). We examined the average number of items needed to satisfy the stopping rules and the corresponding percentage item reduction, level of agreement between person measures estimated from the full IVI item bank and from the CAT simulations, and item exposure rates (IER).

Results

For the overall IVI-CAT, 5 or 9.7 items were required, on average, to obtain moderate or high precision estimates of vision-related quality of life, corresponding to 82.1 and 65.4% item reductions compared to the paper–pencil IVI. Agreement was high between the person measures generated from the full IVI item bank and the IVI-CAT for both the high precision simulation (mean bias, − 0.004 logits; 95% LOA − 0.594 to 0.587) and moderate precision simulation (mean bias, 0.014 logits; 95% LOA − 0.828 to 0.855). The IER for the IVI-CAT in the moderate precision simulation was skewed, with six EWB items used > 40% of the time.

Conclusion

Compared to the paper–pencil IVI instrument, the IVI-CATs required fewer items without loss of measurement precision, making them potentially attractive outcome instruments for implementation into clinical trials, healthcare, and research. Final versions of the IVI-CATs are available.
Bijlagen
Deze inhoud is alleen zichtbaar als je bent ingelogd en de juiste rechten hebt.
Literatuur
Deze inhoud is alleen zichtbaar als je bent ingelogd en de juiste rechten hebt.
Metagegevens
Titel
Optimizing measurement of vision-related quality of life: a computerized adaptive test for the impact of vision impairment questionnaire (IVI-CAT)
Auteurs
Eva K. Fenwick
Bao Sheng Loe
Jyoti Khadka
Ryan E. K. Man
Gwyn Rees
Ecosse L. Lamoureux
Publicatiedatum
09-11-2019
Uitgeverij
Springer International Publishing
Gepubliceerd in
Quality of Life Research / Uitgave 3/2020
Print ISSN: 0962-9343
Elektronisch ISSN: 1573-2649
DOI
https://doi.org/10.1007/s11136-019-02354-y