Gepubliceerd in: Netherlands Heart Journal 7-8/2017

Open Access 13-06-2017 | Original Article - E‑Learning

Mid-term and long-term safety and efficacy of bioresorbable vascular scaffolds versus metallic everolimus-eluting stents in coronary artery disease: A weighted meta-analysis of seven randomised controlled trials including 5577 patients

Auteurs: J. Elias, I. M. van Dongen, R. P. Kraak, R. Y. G. Tijssen, B. E. P. M. Claessen, J. G. P. Tijssen, R. J. de Winter, J. J Piek, J. J. Wykrzykowska, J. P. S. Henriques

Gepubliceerd in: Netherlands Heart Journal | Uitgave 7-8/2017

share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
insite
ZOEKEN

Abstract

Aims

Mid- and long-term safety and efficacy of the Absorb bioresorbable vascular scaffold (BVS) have been studied in randomised trials; however, most were not individually powered for clinical endpoints. We performed a weighted meta-analysis comparing mid- and long-term outcomes in patients treated with the BVS compared with the Xience metallic stent.

Methods and results

Randomised trials comparing the BVS and Xience were identified by searching MEDLINE, EMBASE and conference abstracts. Seven trials were included (BVS n = 3258, Xience n = 2319) with follow-up between 1–3 years. The primary outcome of target lesion failure occurred more frequently in BVS compared with Xience [OR 1.34; 95% CI 1.11–1.62, p = 0.003]. Overall definite or probable device thrombosis occurred more frequently with the BVS [OR 2.86; 95% CI 1.88–4.36, p < 0.001] and this extended beyond 1 year of follow-up [OR 4.13; 95% CI 1.99–8.57, p < 0.001]. Clinically indicated or ischaemia driven target lesion revascularisation [OR 1.43; 95% CI 1.11–1.83, p = 0.005] and myocardial infarction (all MI) [OR 1.64; 95% CI 1.20–2.23, p = 0.002] were more frequently seen in the BVS compared with Xience. Rates of target vessel failure [OR 1.15; 95% CI 0.91–1.46, p = 0.25] and cardiac death [OR 0.91; 95% CI 0.57–1.46, p = 0.71] were not significantly different between BVS and Xience.

Conclusion

This meta-analysis shows a higher rate of target lesion failure and an almost threefold higher rate of device thrombosis in BVS compared with Xience, which extends beyond the first year. Device thrombosis did not lead to an overall increased (cardiac) mortality.

Introduction

Bioresorbable scaffolds may theoretically overcome some limitations of current generation drug-eluting stents [1]. The Absorb (Abbott Vascular, Santa Clara, California, USA) bioresorbable vascular scaffold (BVS) is the most widely used bioresorbable device. Clinical trials enrolling patients with strict inclusion and exclusion criteria showed that the use of the BVS was safe and feasible with acceptable short- and mid-term clinical outcomes [27]. However, registries performed in more complex patients and lesions reported higher rates of early and late scaffold thrombosis [810]. In the ABSORB II trial, an ongoing risk of scaffold thrombosis up to 3 years of follow-up was observed [11]. The ABSORB III trial showed significantly higher 2‑year target lesion failure in the BVS compared with Xience [12], leading to an US Food and Drug Administration (FDA) warning [13]. The AIDA trial included a patient population reflecting routine clinical practice, and reported data earlier due to safety concerns. In AIDA, treatment with the BVS compared with Xience was associated with an increased incidence of device thrombosis throughout a median follow-up of 2 years [14]. A previous meta-analysis of randomised controlled trials comparing the BVS with Xience showed higher rates of scaffold thrombosis, mainly in the acute and subacute phase [15]. More recently, various trials also raised concerns on the use of the BVS with a longer follow-up, with a higher incidence of late and very late scaffold thrombosis [11, 12, 14, 1620]. Sorrentino et al. performed a meta-analysis of randomised clinical trials with longer follow-up and raised the same concerns regarding the Absorb BVS; however, they did not perform an analysis on the events occurring beyond 1 year [21]. We performed a weighted meta-analysis on the available randomised controlled trials comparing mid- and long-term outcome (>12-month follow-up), together with a landmark analysis beyond 1 year of follow-up, in BVS compared with Xience metallic stent.

Methods

Search strategy and study selection

We searched PubMed, MEDLINE, and EMBASE for randomised studies on the BVS compared with Xience from inception to March 29th 2017. There were no language or other restrictions, and the results were only filtered on human studies. The search consisted of the following search terms including keywords and MESH terms for ‘Bioabsorbable’, ‘ABSORB’, ‘Bioresorbable stent’, ‘Everolimus’, ‘Controlled Clinical trial’ and ‘Randomized controlled trial’ (see the online Electronic Supplementary Material (ESM) for the complete MEDLINE search).
All retrieved studies were first screened independently by two of the investigators (JE and ID) at the title and/or abstract level. The remaining applicable studies were then reviewed in detail according to the following predefined inclusion and exclusion criteria. Inclusion criteria were randomised design, ≥50 enrolled patients and performance of an intention-to-treat analysis. Exclusion criteria were non-human studies or another comparison than of BVS versus Xience. If there were no published trial data on follow-up beyond 1 year, we searched for additional conference proceedings on long-term follow-up data of the particular trial.

Risk of bias assessment and data extraction

Risk of bias in the included trials was assessed using the Cochrane risk of bias assessment tool in Review Manager (Version 5.3. Copenhagen, the Cochrane Collaboration, 2014), and data of the included trials were extracted by two of the investigators (JE and ID) [22]. Data were extracted from design papers, main papers, follow-up papers, conference proceedings and/or presentation slides, and combined in an Excel spreadsheet for further calculations where necessary.

Study outcomes

The primary efficacy outcome was target lesion failure (TLF), a combined endpoint of cardiac death, target vessel myocardial infarction (TV-MI) and target lesion revascularisation (TLR). The primary safety outcome was definite or probable device thrombosis. Secondary outcomes were clinically indicated or ischaemia driven target lesion revascularisation (ID-TLR), the device oriented combined endpoint target vessel failure (TVF) consisting of cardiac death, target vessel MI (TV-MI) and target vessel revascularisation (TVR), as well as the occurrence of target vessel MI, all MI, all-cause death and cardiac death. All endpoints were defined according to the definitions of the original trials, and assessed according to the intention-to-treat analysis at the longest follow-up available. To assess long-term efficacy and safety we performed a landmark analysis after 1 year of follow-up comparing the rates of target lesion failure and device thrombosis occurring beyond 1 year of follow-up. For this landmark analysis patients were included in the denominator if they were free of the event of interest at 1‑year follow-up. Patients who withdrew informed consent, were lost-to-follow-up or died before 1‑year follow-up were excluded from the denominator.

Statistical analysis

Continuous variables are reported as mean (±SD), categorical variables are expressed as n/N (%). The meta-analysis and statistical analysis for pooled odds ratios (ORs) was performed using the Peto fixed-effects model for categorical variables. Pooled ORs were calculated and are reported with 95% confidence intervals, a p-value <0.05 was considered statistically significant. Statistical heterogeneity was tested using the χ 2  test and the I 2  test. I 2  < 25% was considered to be low, 25–50% moderate, and >50% high heterogeneity. If no events occurred, the trial could not be added to the pooled ORs. All meta-analyses were performed on intention-to-treat basis and were performed with the Review Manager. To assess for publication bias, funnel plots were constructed for the primary outcomes. Additionally, we performed an influence analysis by omitting one trial at a time, and we carried out the Egger’s asymmetry test [23].

Results

The search identified 422 publications. In total, seven eligible randomised controlled trials comparing BVS and Xience were identified after screening [11, 12, 14, 1619]. For four trials the 2‑year outcomes were only available as conference proceedings [12, 1719]. Fig. 1 depicts the flow diagram of the search; the MEDLINE search strategy and risk of bias assessment of the included trials are shown in the online ESM files. One trial had a third group of patients receiving a Biolimus-eluting stent; results from this patient group were excluded [17]. The ABSORB II trial started enrolment in 2011 and is depicted as ‘ABSORB II (2011)’ and so on. The primary objective of the original trials differed: three trials investigated clinical outcomes, three trials investigated late lumen loss on follow-up angiography and one trial investigated the optimal frequency domain imaging-derived healing score at 6 months. Follow-up duration also differed: one trial described a 3-year follow-up, five trials described 2‑year follow-up and one trial reported a median follow-up duration of two years [Q1-Q3: 507-895 days]. Definitions of target lesion failure, target lesion failure, and aspirin and dual antiplatelet therapy (DAPT) prescriptions differed between some of the trials. Table 1 of the online ESM shows all the relevant trial characteristics. The degree of bias within included trials was small (ESM Table 2).

Patient and lesion characteristics

The seven trials included 5577 patients, randomised to either BVS (n = 3258) or Xience (n = 2319). The pooled mean age was 63 ± 10 years, with 66.7% of patients being male and 25.2% diabetic, of which 32% insulin-dependent. In total, 12.0% of patients presented with non-ST-elevated myocardial infarction (STEMI) on admission, 7.3% non-STEMI and 20.6% unstable angina pectoris. Periprocedural DAPT was administered in 98.9%. Table 1 shows the baseline characteristics of the patients and lesions included in the trials.
Table 1
Patient and lesion characteristics per included trial
 
ABSORB II (2011)
EVERBIO II (2012)
ABSORB China (2013)
ABSORB Japan (2013)
AIDA (2013)
ABSORB III (2013)
TROFI II (2014)
Patient characteristics
Randomised, n
501
240
480
400
1854
2008
191
Included, n
501
158
475
400
1845
2008
191
Age (years)
61 ± 10
65 ± 11
57 ± 11
67±9
64 ± 11
64 ± 11
59 ± 10
Men
385 (77)
125 (79)
343 (72)
309 (77)
1370 (74)
1415 (70)
157 (82)
Diabetes
120 (24)
30 (19)
115 (24)
144 (36)
324 (18)
640 (32)
32 (17)
– Insulin dependent
36 (7)
5 (3)
41 (9)
35 (9)
110 (6)
215 (11)
8 (4)
Dyslipidaemia
385 (77)
94 (5)
192 (40)
328 (82)
694 (38)
1732 (86)
115 (6)
ACS at admission
105 (21)
55 (35)
306 (64)
48 (12)
1029 (56)
523 (26)
191 (100)
– STEMI
0
15 (9)
0
0
465 (25)
0
191 (100)
– NSTEMI
0
29 (18)
0
0
377 (20)
0
0
– UAP
105 (21)
11 (7)
306 (64)
48 (12)
157 (9)
523 (26)
0
DAPTa
472 (94)
158 (100)
468 (99)
400 (100)
1845 (100)
1987 (99)
191 (100)
– Clopidogrel or Ticlopidine
427 (90)
NA
465 (99)
400 (100)
645 (35)
1268 (64)
65 (34)
– Prasugrel or Ticagrelor
45 (20)
NA
3 (1)
0
1198 (65)
719 (36)
127 (66)
Lesion characteristics
Randomised, n
546
208
503
412
2446
2098
193
Diameter stenosis (%)
59.0 ± 11.3
80.5 ± 15.7
64.9 ± 0.82
64.6 ± 11.1
NA
65.5 ± 12.2
89.7 ± 15.3
RVD (mm)
2.60 ± 0.39
2.57 ± 0.65
2.81 ± 0.03
2.74 ± 0.45
3.05 ± 0.42
2.66 ± 0.45
2.81 ± 0.50
Length (mm)
13.8 ± 11.4
NA
14.0 ± 0.31
13.4 ± 5.36
19.0 ± 9.25
12.8 ± 5.5
13.1 ± 7.2
Type B2/C
254 (47)
67 (32)
369 (74)
313 (76)
1288 (53)
1462 (70)
NA
Overall baseline patient and lesion characteristics per included trial. Data are presented as number (%) and continuous data as mean (±SD). ACS acute coronary syndrome, STEMI ST-elevated myocardial infarction, NSTEMI non-ST-elevated myocardial infarction, UAP unstable angina pectoris, DAPT dual anti-platelet therapy, RVD reference vessel diameter
aPeri-procedural
In total, 6406 lesions were included in the trials of which 58% were randomised to BVS implantation. Pre-dilatation was performed in 97.7% of BVS, and in 93.5% of Xience-treated lesions. Post-dilatation was performed in 66.7% of BVS, and in 50.3% of Xience-treated patients. Device success, reported in six trials, was achieved in 96.3% of BVS, and in 99.4% of Xience patients. Table 2 depicts all available device implantation characteristics.
Table 2
Device implantation characteristics
 
ABSORB II
(2011)
EVERBIO II
(2012)
ABSORB China (2013)
ABSORB Japan (2013)
AIDA (2013)
ABSORB III
(2013)
TROFI II
(2014)
Absorb
Xience
Absorb
Xience
Absorb
Xience
Absorb
Xience
Absorb
Xience
Absorb
Xience
Absorb
Xience
Pre-dilatation
364 (100)
180 (99)
93 (97)a
96 (86)
250 (99.6)
247 (98.0)
275 (100)
137 (100)
1199a,c (97)
1103c (91)
NA
NA
53 (55.8)
50 (51.0)
Pre-dilatation balloon size
NA
NA
NA
NA
2.8 ± 0.4
2.7 ± 0.4
2.80 ± 0.37
2.86 ± 0.36
2.71 ± 0.38a
2.64 ± 0.38
NA
NA
NA
NA
Pre-dilatation maximum pressure
NA
NA
NA
NA
12.4 ± 3.3a
11.8 ± 3.3
11.6 ± 3.8
11.9 ± 3.7
11.8 ± 3.0a
11.3 ± 3.0
NA
NA
NA
NA
Nominal size scaffold/stent
3.01 ± 0.31
3.05 ± 0.28
3.1 ± 0.4
3.0 ± 1.0
3.1 ± 0.4
3.1 ± 0.4
3.09 ± 0.37
3.13 ± 0.38
3.07 ± 0.37
3.05 ± 0.40
3.18 ± 0.43a
3.12 ± 0.45
3.25 ± 0.30a
3.12 ± 0.37
Implantation maximum balloon pressure
14.23 ± 3.43b
15.03 ± 3.33b
13.6 ± 2.8a
14.6 ± 2.9
12.8 ± 2.4
12.8 ± 2.8
10.4 ± 3.0a
11.2 ± 2.7
13.0 ± 2.7a
13.5 ± 2.7
15.4 ± 3.0
15.4 ± 3.2
14.1 ± 3.8
13.3 ± 3.0
Post-dilatation
221 (61)
107 (59)
33 (34)
35 (31)
162a,c (63)
141c (54.4)
226c (82.2)
106c (77.4)
915c (74)a
594c (49)
866a (65.5)
351 (51.2)
48a (50.5)
25 (25.5)
Post-dilatation balloon size
3.08 ± 0.34b
3.16 ± 0.36b
NA
NA
3.3 ± 0.4
3.2 ± 0.4
3.18 ± 0.44a
3.29 ± 0.51
3.28 ± 0.44
3.29 ± 0.49
NA
NA
3.51 ± 0.34
3.29 ± 0.62
Post-dilatation with non-compliant balloon
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
43a (89.6)
13 (52.0)
Post-dilatation maximum balloon pressure
b
b
NA
NA
16.8 ± 3.8
16.9 ± 3.4
15.5 ± 4.2
16.0 ± 3.9
15.4 ± 3.8
15.6 ± 3.5
NA
NA
15.8 ± 3.4a
18.6 ± 3.9
Post-dilatation balloon >0.5 mm
b
b
NA
NA
NA
NA
9c
(4.0)
NA
18/912
(2)
14/593 (2)
NA
NA
NA
NA
Device success
99%
100%
NA
NA
98%
99.6%
98.9%
99.3%
92%a
98%
94.3%a
99.3%
95.8%
100%
Available device implantation characteristics and device success per included trial. Data are presented as number (%) and continues data as mean (±SD)
aSignificantly different from Xience group
bImplant or post-dilatation
cPer treated lesion
NA not applicable

Primary and secondary endpoints

The primary outcome of target lesion failure occurred significantly more often with the BVS [OR 1.34; 95% CI 1.11–1.62, p = 0.003]. Definite or probable stent thrombosis occurred significantly more frequently in patients treated with the BVS (crude rates; BVS 2.4%, Xience 0.7% [OR 2.86; 95% CI 1.88–4.36, p < 0.001]) (Fig. 2). Timing of scaffold and stent thrombosis events differed between the two devices. Early device thrombosis occurred in 34 of BVS and in 11 of Xience-treated patients, late device thrombosis in 17 of BVS and in 2 of Xience-treated patients, and very late in 26 of BVS and 3 of Xience-treated patients (Table 3). ESM Fig. 3 depicts the funnel plots of both primary endpoints. Visual estimation of the funnel plots did not suggest any important influence of small studies on the primary study outcomes, nor did the Egger’s asymmetry tests for target lesion failure (intercept 0.117 [95% CI −1.539–1.772], two-sided p-value of 0.863) and definite/probable device thrombosis (intercept 0.322 [95% CI −0.936–1.580], two-sided p-value of 0.539). The influence analysis showed that by omitting every trial, the total ORs did not alter direction (ESM Tables 3 and 4).
Table 3
Timing of stent or scaffold thrombosis cases per included trial
 
ABSORB II
(2011)
EVERBIO II
(2012)
ABSORB China
(2013)
ABSORB Japan
(2013)
AIDA (2013)
ABSORB III
(2013)
TROFI II
(2014)
 
Absorb
(335)
Xience
(166)
Absorb
(78)
Xience
(80)
Absorb
(238)
Xience
(237)
Absorb
(266)
Xience
(133)
Absorb
(924)
Xience
(921)
Absorb
(1322)
Xience
(686)
Absorb
(95)
Xience
(96)
Early ST (0–30 days)
2
0
0
0
1
0
3
1
13
5
14
5
1
0
Late ST (31 days–1 year)
1
0
1
0
0
0
1
1
8
1
6
0
0
0
Very late ST (>1 year)
6
0
0
0
1
0
4
0
10
2
4
0
1
1
Cases of definite or probable stent/scaffold thrombosis (ST) divided over early, late and very late time points after the index procedure. ST scaffold or stent thrombosis
Secondary outcomes showed that clinically indicated or ischaemia driven target lesion revascularisation, all MI and target vessel MI occurred significantly more frequently with the BVS. The rate of target vessel failure was not significantly different between BVS and Xience. All-cause death [OR 0.70; 95% CI 0.48–1.03, p = 0.07] and cardiac death [OR 0.91; 95% CI 0.57–1.46, p = 0.71] were also non-significantly different between the BVS and Xience (Fig. 3). Heterogeneity was low for all outcomes (0–7%).
In ESM Figs. 1 and 2, forest plots of the primary and secondary endpoints at 1 year (for EVERBIO II at 9‑month follow-up and for TROFI II at 6‑month follow-up) are depicted. At 1‑year follow-up, definite or probable device thrombosis, all MI and target vessel MI occurred significantly more frequently with the BVS: OR 2.43 [95% CI 1.45–4.04, p < 0.001], OR 1.39 [95% CI 1.06–1.82, p = 0.02] and OR 1.48 [95% CI 1.09–2.01, p = 0.01] respectively. All other endpoints at 1‑year follow-up were not significantly different between the two treatment groups.
Fig. 4 shows the number of the primary outcome events and associated odds ratios beyond 1 year of follow-up (for EVERBIO II beyond 9 months of follow-up and for TROFI II beyond 6 months of follow-up). Occurrence of target lesion failure events after 1 year occurred significantly more frequently in the BVS patients [OR 1.55; 95% CI 1.12–2.14, p = 0.008] and device thrombosis after 1‑year follow-up occurred in 27 patients treated with the BVS and in 3 patients treated with Xience [OR 4.13; 95% CI 1.99–8.57, p < 0.001]. During all time periods (early, late and very late) device thrombosis rates were higher in the BVS group (Fig. 5).
Considering 4 of the 7 randomised trials did not publish their long-term data, we also performed a meta-analysis of the primary endpoint using only the published trials (n = 3). However, excluding these trials did not lead to a major difference in primary outcomes (target lesion failure: OR 1.34; 95% CI 1.02–1.76, p = 0.03; definite or probable device thrombosis: OR 3.17; 95% CI 1.87–5.38, p < 0.001) (ESM Fig. 4).

Discussion

This meta-analysis showed a higher target lesion failure in BVS compared with the Xience. Also, in BVS, a highly significantly increased risk for definite and probable device thrombosis was observed compared with Xience. The incidence of all-cause mortality and cardiac death was not significantly different between the two groups.
Our meta-analysis demonstrates an ongoing higher risk of device thrombosis throughout the follow-up. Acute and subacute scaffold thrombosis has been attributed to inadequate DAPT and suboptimal implantation techniques of the BVS. One of the most intriguing findings of this meta-analysis is the ongoing and increased risk for definite or probable device thrombosis beyond 1 year of follow-up. These late and very-late scaffold thromboses are probably associated with different mechanisms and may be associated with resorption-related scaffold discontinuity and dismantling. Factors affecting flow conditions, such as (late-acquired) malapposed and uncovered struts due to heterogeneous endothelialisation of the scaffold, have also been suggested as potential causes [24, 25].
A specific BVS implantation protocol has been proposed to reduce the rates of scaffold thrombosis. This protocol consists of adequate pre-dilatation, correct sizing and post-dilatation (PSP) [26]. While this suggests that improved implantation techniques can prevent early device thrombosis, the effect of implantation techniques on long-term outcomes is less clear. Nevertheless, it is important to point out that post-dilatation was only performed in about 50% of the patients included in previous studies with infrequent use of intracoronary imaging [27]. In the studies included in this meta-analysis post-dilatation was only performed in 65–80% of the patients. Furthermore in a separate analysis performed by Stone pooling of previous ABSORB studies only 60.1% received predilatation and just 12.4% of patients received adequate high-pressure postdilatation with a noncompliant balloon [28].
The duration of DAPT is potentially associated with the occurrence of late scaffold thrombosis. The AIDA trial investigators very recently recommended continuation of DAPT for all BVS patients until 3 years post index PCI [14]. This recommendation is supported by the results from the DAPT trial: treatment with metallic drug-eluting stents and DAPT beyond 1 year compared with aspirin alone was associated with a significantly reduced risk of stent thrombosis and cardiovascular events [29]. Optimal DAPT duration for patients treated with BVS is unknown and might be challenging to determine given the variation in resorption time in every patient and lesion type. Furthermore, it is currently unknown if prolongation of DAPT will prevent late and very-late scaffold thrombosis.
Although the early and late thrombotic events in patients treated with the BVS are associated with worse outcome, these events did not translate into an overall higher mortality when compared with Xience. The bioresorbable technology holds great theoretical benefits, which can be expected to occur several years after implantation of the scaffold when the scaffold is completely dissolved. However, the BVS failed to demonstrate superiority in terms of vasomotion and did not meet non-inferiority in terms of late lumen loss [11, 16]. Therefore the suggested advantages of the BVS still need to be established. However, with current safety issues completing the ongoing future trials, COMPARE ABSORB and ABSORB IV might be challenging; nevertheless, long-term follow-up of these trials will shed additional light on the use of the first-generation BVS in more-complex patients.
Our study has several limitations: most of the trials included in this meta-analysis enrolled highly selected, mainly stable patients with non-complex lesions. Therefore generalising the results to all-comer populations should be done with caution. Also, our meta-analysis only included studies comparing the Absorb BVS to the Xience stent, therefore the results do not apply to other ‘bioresorbable stents’. None of the randomised trials were adequately powered for differences in individual clinical endpoints or for relatively rare endpoints. Furthermore, all the included trials used different event definitions and no patient-level data were available to examine predictors of worse outcome. There was only one study that reported a 3 year follow-up, other trials had a follow-up of 2 years or less, one trial reported median follow-up of 2 years. Since the resorption process of the scaffold is probably not completed at that time, extended follow-up is needed to fully assess the possible effect of the dissolving BVS on clinical outcomes.
In conclusion, this meta-analysis shows a significantly higher rate of target lesion failure and an almost threefold higher rate of device thrombosis in BVS compared with Xience metallic stent. This led to an increased incidence of MI, but not to an overall increased mortality. Further extension of follow-up will be essential to determine very long term clinical effects after full resorption of the first generation coronary bioresorbable scaffold.

Funding

None.

Conflict of interest

Dr. J.P.S. Henriques reports grants from Abbott Vascular, grants from Abiomed Inc, grants from B‑Braun, outside the submitted work; Dr. J.J. Wykrzykowska receives consultancy fees from Xience and a research grant from Abbott Vascular. Dr. J.J. Piek reports grants and personal fees from Member MAB Abbott Vascular, grants and personal fees from Consultant Philips/Volcano, grants and personal fees from Previous consultant Miracor, outside the submitted work. Dr. R.J. de Winter reports grants from Abbott Vascular, outside the submitted work. J. Elias, I.M. van Dongen, R.P. Kraak, R.Y.G. Tijssen, B.E.P.M. Claessen and J.G.P. Tijssen declare that they have no competing interests.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

Netherlands Heart Journal

Het Netherlands Heart Journal wordt uitgegeven in samenwerking met de Nederlandse Vereniging voor Cardiologie en de Nederlandse Hartstichting. Het tijdschrift is Engelstalig en wordt gratis beschikbaa ...

Literatuur
1.
go back to reference Serruys PW, Garcia-Garcia HM, Onuma Y. From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade? Eur Heart J. 2012;33:16–25b.CrossRefPubMed Serruys PW, Garcia-Garcia HM, Onuma Y. From metallic cages to transient bioresorbable scaffolds: change in paradigm of coronary revascularization in the upcoming decade? Eur Heart J. 2012;33:16–25b.CrossRefPubMed
2.
go back to reference Ellis SG, Kereiakes DJ, Metzger DC, et al. Everolimus-eluting bioresorbable scaffolds for coronary artery disease. N Engl J Med. 2015;373:1905–15.CrossRefPubMed Ellis SG, Kereiakes DJ, Metzger DC, et al. Everolimus-eluting bioresorbable scaffolds for coronary artery disease. N Engl J Med. 2015;373:1905–15.CrossRefPubMed
3.
go back to reference Gao R, Yang Y, Han Y, et al. Bioresorbable vascular scaffolds versus metallic stents in patients with coronary artery disease: ABSORB China trial. J Am Coll Cardiol. 2015;66:2298–309.CrossRefPubMed Gao R, Yang Y, Han Y, et al. Bioresorbable vascular scaffolds versus metallic stents in patients with coronary artery disease: ABSORB China trial. J Am Coll Cardiol. 2015;66:2298–309.CrossRefPubMed
4.
go back to reference Kimura T, Kozuma K, Tanabe K, et al. A randomized trial evaluating everolimus-eluting Absorb bioresorbable scaffolds vs. everolimus-eluting metallic stents in patients with coronary artery disease: ABSORB Japan. Eur Heart J. 2015;36:3332–42.CrossRefPubMed Kimura T, Kozuma K, Tanabe K, et al. A randomized trial evaluating everolimus-eluting Absorb bioresorbable scaffolds vs. everolimus-eluting metallic stents in patients with coronary artery disease: ABSORB Japan. Eur Heart J. 2015;36:3332–42.CrossRefPubMed
5.
go back to reference Puricel S, Arroyo D, Corpataux N, et al. Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds. J Am Coll Cardiol. 2015;65:791–801.CrossRefPubMed Puricel S, Arroyo D, Corpataux N, et al. Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds. J Am Coll Cardiol. 2015;65:791–801.CrossRefPubMed
6.
go back to reference Sabate M, Windecker S, Iniguez A, et al. Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction: results of the randomized ABSORB ST-segment elevation myocardial infarction-TROFI II trial. Eur Heart J. 2016;37:229–40.CrossRefPubMed Sabate M, Windecker S, Iniguez A, et al. Everolimus-eluting bioresorbable stent vs. durable polymer everolimus-eluting metallic stent in patients with ST-segment elevation myocardial infarction: results of the randomized ABSORB ST-segment elevation myocardial infarction-TROFI II trial. Eur Heart J. 2016;37:229–40.CrossRefPubMed
7.
go back to reference Serruys PW, Chevalier B, Dudek D, et al. A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1‑year analysis of clinical and procedural secondary outcomes from a randomised controlled trial. Lancet. 2015;385:43–54.CrossRefPubMed Serruys PW, Chevalier B, Dudek D, et al. A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II): an interim 1‑year analysis of clinical and procedural secondary outcomes from a randomised controlled trial. Lancet. 2015;385:43–54.CrossRefPubMed
8.
go back to reference Capodanno D, Gori T, Nef H, et al. Percutaneous coronary intervention with everolimus-eluting bioresorbable vascular scaffolds in routine clinical practice: early and midterm outcomes from the European multicentre GHOST-EU registry. EuroIntervention. 2015;10:1144–53.CrossRefPubMed Capodanno D, Gori T, Nef H, et al. Percutaneous coronary intervention with everolimus-eluting bioresorbable vascular scaffolds in routine clinical practice: early and midterm outcomes from the European multicentre GHOST-EU registry. EuroIntervention. 2015;10:1144–53.CrossRefPubMed
9.
go back to reference Felix CM, Fam JM, Diletti R, et al. Mid- to long-term clinical outcomes of patients treated with the everolimus-eluting bioresorbable vascular scaffold: the BVS expand registry. JACC Cardiovasc Interv. 2016;9:1652–63.CrossRefPubMed Felix CM, Fam JM, Diletti R, et al. Mid- to long-term clinical outcomes of patients treated with the everolimus-eluting bioresorbable vascular scaffold: the BVS expand registry. JACC Cardiovasc Interv. 2016;9:1652–63.CrossRefPubMed
10.
go back to reference Ishibashi Y, Nakatani S, Onuma Y. Definite and probable bioresorbable scaffold thrombosis in stable and ACS patients. EuroIntervention. 2015;11:e1–2.CrossRefPubMed Ishibashi Y, Nakatani S, Onuma Y. Definite and probable bioresorbable scaffold thrombosis in stable and ACS patients. EuroIntervention. 2015;11:e1–2.CrossRefPubMed
11.
go back to reference Serruys PW, Chevalier B, Sotomi Y, et al. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial. Lancet. 2016;388:2479–91.CrossRefPubMed Serruys PW, Chevalier B, Sotomi Y, et al. Comparison of an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent for the treatment of coronary artery stenosis (ABSORB II): a 3 year, randomised, controlled, single-blind, multicentre clinical trial. Lancet. 2016;388:2479–91.CrossRefPubMed
12.
go back to reference Ellis SG. Everolimus-eluting bioresorbable vascular scaffolds in patients with coronary artery disease: aBSORB III trial 2‑year results. American College of Cardiology, Washington DC, 18 March 2017. 2017. Ellis SG. Everolimus-eluting bioresorbable vascular scaffolds in patients with coronary artery disease: aBSORB III trial 2‑year results. American College of Cardiology, Washington DC, 18 March 2017. 2017.
15.
go back to reference Cassese S, Byrne RA, Ndrepepa G, et al. Everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents: a meta-analysis of randomised controlled trials. Lancet. 2016;387:537–44.CrossRefPubMed Cassese S, Byrne RA, Ndrepepa G, et al. Everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents: a meta-analysis of randomised controlled trials. Lancet. 2016;387:537–44.CrossRefPubMed
16.
go back to reference Onuma Y, Sotomi Y, Shiomi H, et al. Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimuseluting bioresorbable scaffold and an everolimus-eluting metallic stent: Insights from the randomised ABSORB Japan trial. EuroIntervention. 2016;12:1090–101.CrossRefPubMed Onuma Y, Sotomi Y, Shiomi H, et al. Two-year clinical, angiographic, and serial optical coherence tomographic follow-up after implantation of an everolimuseluting bioresorbable scaffold and an everolimus-eluting metallic stent: Insights from the randomised ABSORB Japan trial. EuroIntervention. 2016;12:1090–101.CrossRefPubMed
17.
go back to reference Puricel S. Comparison of everolimus-and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds: 2‑year outcomes of the EVERBIO II trial. Transcatheter Cardiovascular Therapeutics, San Fransisco, 14 October 2015. 2015. Puricel S. Comparison of everolimus-and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds: 2‑year outcomes of the EVERBIO II trial. Transcatheter Cardiovascular Therapeutics, San Fransisco, 14 October 2015. 2015.
18.
go back to reference Sabate M. BRS in STEMI: rationale, registry outcomes and Trofi II 2‑year results. Transcatheter Cardiovascular Therapeutics, Washington DC, 31 October 2016. 2016. Sabate M. BRS in STEMI: rationale, registry outcomes and Trofi II 2‑year results. Transcatheter Cardiovascular Therapeutics, Washington DC, 31 October 2016. 2016.
19.
go back to reference Gao R. ABSORB China: two-year clinical results in patients with coronary artery disease randomized to the absorb bioresorbable vascular scaffold versus metallic drug-eluting stents. Transcatheter Cardiovascular Therapeutics, Washington DC, 30 October 2016. 2016. Gao R. ABSORB China: two-year clinical results in patients with coronary artery disease randomized to the absorb bioresorbable vascular scaffold versus metallic drug-eluting stents. Transcatheter Cardiovascular Therapeutics, Washington DC, 30 October 2016. 2016.
20.
go back to reference Mahmoud AN, Barakat AF, Elgendy AY, et al. Long-term efficacy and safety of everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents: a meta-analysis of randomized trials. Circ Cardiovasc Interv. 2017;10:e005286.CrossRefPubMed Mahmoud AN, Barakat AF, Elgendy AY, et al. Long-term efficacy and safety of everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting metallic stents: a meta-analysis of randomized trials. Circ Cardiovasc Interv. 2017;10:e005286.CrossRefPubMed
21.
go back to reference Sorrentino S, Giustino G, Mehran R, et al. Everolimus-eluting bioresorbable scaffolds versus metallic everolimus-eluting stents: meta-analysis of randomized controlled trials. J Am Coll Cardiol. 2017; doi:10.1016/j.jacc.2017.04.011. Sorrentino S, Giustino G, Mehran R, et al. Everolimus-eluting bioresorbable scaffolds versus metallic everolimus-eluting stents: meta-analysis of randomized controlled trials. J Am Coll Cardiol. 2017; doi:10.​1016/​j.​jacc.​2017.​04.​011.
24.
go back to reference Sotomi Y, Suwannasom P, Serruys PW, Onuma Y. Possible mechanical causes of scaffold thrombosis: insights from case reports with Intracoronary imaging. EuroIntervention. 2016;12:1747–56. doi:10.4244/eij-d-16-00471.CrossRef Sotomi Y, Suwannasom P, Serruys PW, Onuma Y. Possible mechanical causes of scaffold thrombosis: insights from case reports with Intracoronary imaging. EuroIntervention. 2016;12:1747–56. doi:10.​4244/​eij-d-16-00471.CrossRef
26.
go back to reference Puricel S, Cuculi F, Weissner M, et al. Bioresorbable coronary scaffold thrombosis: multicenter comprehensive analysis of clinical presentation, mechanisms, and predictors. J Am Coll Cardiol. 2016;67:921–31.CrossRefPubMed Puricel S, Cuculi F, Weissner M, et al. Bioresorbable coronary scaffold thrombosis: multicenter comprehensive analysis of clinical presentation, mechanisms, and predictors. J Am Coll Cardiol. 2016;67:921–31.CrossRefPubMed
27.
28.
go back to reference Stone G. Impact of technique on early and late outcomes following coronary bioresorbable scaffold implantation: analysis from the ABSORB trials. Cardiovasc Res Technol. 2017. Conference Proceedings. 21 February 2017, Washington. Stone G. Impact of technique on early and late outcomes following coronary bioresorbable scaffold implantation: analysis from the ABSORB trials. Cardiovasc Res Technol. 2017. Conference Proceedings. 21 February 2017, Washington.
29.
go back to reference Mauri L, Kereiakes DJ, Yeh RW, et al. Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents. N Engl J Med. 2014;371:2155–66.CrossRefPubMedPubMedCentral Mauri L, Kereiakes DJ, Yeh RW, et al. Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents. N Engl J Med. 2014;371:2155–66.CrossRefPubMedPubMedCentral
Metagegevens
Titel
Mid-term and long-term safety and efficacy of bioresorbable vascular scaffolds versus metallic everolimus-eluting stents in coronary artery disease: A weighted meta-analysis of seven randomised controlled trials including 5577 patients
Auteurs
J. Elias
I. M. van Dongen
R. P. Kraak
R. Y. G. Tijssen
B. E. P. M. Claessen
J. G. P. Tijssen
R. J. de Winter
J. J Piek
J. J. Wykrzykowska
J. P. S. Henriques
Publicatiedatum
13-06-2017
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 7-8/2017
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-017-1008-x

Andere artikelen Uitgave 7-8/2017

Netherlands Heart Journal 7-8/2017 Naar de uitgave