Gal et al. [1] reported the results of the 50 patients treated for atrial fibrillation (AF) using the endoscopic laser balloon ablation system (EAS) in the Netherlands, who were recruited for the study between December 2011 and December 2013. The second-generation EAS uses a compliant balloon to improve balloon/tissue contact, which improves the energy delivery to create consistent lesions and, ultimately, to achieve durable pulmonary vein (PV) isolation. The study’s mean procedure and fluoroscopy time were 171 and 36 min, respectively. Temporary phrenic nerve palsy was observed during a single procedure. After a median follow-up of 17.3 (12.9–19.5) months, 58 % of the patients remained free of AF, after a single EAS PV isolation without the use of antiarrhythmic drugs.
Between November 2012 and July 2013, 24 patients underwent PV isolation using the second-generation EAS at the Maastricht University Medical Center. Oesophageal temperature monitoring was adopted for all patients to avoid undesired excessive oesophageal thermal injury. Acute PV isolation was achieved in all 80 PVs of 20 patients (100 %). The mean procedure and fluoroscopy time were comparable with that of Gal et al., 180 ± 44 and 25 ± 10 min, respectively. In all of these patients except four, a bolus of 15–21 mg of adenosine was injected followed by a rapid saline flush, 30 min after the last energy application [2]. Restoration of electrical conduction by adenosine-mediated hyperpolarisation occurred in 11 PVs (13.7 %) in seven patients (35 %), namely the left superior PV in four, the left inferior PV in two, the right superior PV in four, and the right inferior PV in one. Additional EAS-guided ablation was performed in these veins achieving complete isolation. We did not observe any oesophageal temperature rise above 39 °C for any of the patients. The complication rate was relatively low with one case of spontaneously resolving phrenic nerve palsy, one patient with transient ST-segment elevation conservatively managed by sublingual nitroglycerin, and one groin haematoma.
After a 3-month blanking period, patients received a 24–48 h Holter monitor every 3 months for 1 year to assess AF recurrence. Previously, we have reported that of these patients, 85 % were free of AF without antiarrhythmic drugs, after a median follow-up of 267 ± 76.9 days [3]. Currently, after a follow-up of 18.9 ± 2.3 months, the success rate is 81 % [4].
The higher medium-term AF-free survival after EAS-PV isolation at Maastricht may be partly explained by a potentially shorter learning curve due to prior experience with a similar balloon-based ablation system, i.e. cryoballoon. In addition, the elimination of adenosine-mediated PV reconnections may have contributed to the clinical benefit, although the incremental value remains to be resolved. In addition, elimination adenosine-mediated PV reconnections may have increased the overall success rate [5, 6].
Funding
None.
Conflict of interest
None declared.
Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

Netherlands Heart Journal

Het Netherlands Heart Journal wordt uitgegeven in samenwerking met de Nederlandse Vereniging voor Cardiologie en de Nederlandse Hartstichting. Het tijdschrift is Engelstalig en wordt gratis beschikbaa ...

Literatuur
1.
go back to reference Gal P, Smit JJ, Adiyaman A, Ramdat Misier AR, Delnoy PP, Elvan A. First Dutch experience with the endoscopic laser balloon ablation system for the treatment of atrial fibrillation. Neth Heart J. 2015;23:96–9. doi:10.1007/s12471-014-0624-y.PubMedCentralPubMedCrossRef Gal P, Smit JJ, Adiyaman A, Ramdat Misier AR, Delnoy PP, Elvan A. First Dutch experience with the endoscopic laser balloon ablation system for the treatment of atrial fibrillation. Neth Heart J. 2015;23:96–9. doi:10.1007/s12471-014-0624-y.PubMedCentralPubMedCrossRef
2.
go back to reference Kumar N, Blaauw Y, Timmermans C, Pison L, Vernooy K, Crijns H. Adenosine testing after second-generation balloon devices (cryothermal and laser) mediated pulmonary vein ablation for atrial fibrillation. J Interv Card Electrophysiol. 2014;41:91–7.PubMedCrossRef Kumar N, Blaauw Y, Timmermans C, Pison L, Vernooy K, Crijns H. Adenosine testing after second-generation balloon devices (cryothermal and laser) mediated pulmonary vein ablation for atrial fibrillation. J Interv Card Electrophysiol. 2014;41:91–7.PubMedCrossRef
3.
go back to reference Kumar N, Phan K, Timmermans C, et al. Catheter ablation of atrial fibrillation: the missing links. Eur Heart J. 2014. doi:10.1093/eurheartj/ehu291. Kumar N, Phan K, Timmermans C, et al. Catheter ablation of atrial fibrillation: the missing links. Eur Heart J. 2014. doi:10.1093/eurheartj/ehu291.
4.
go back to reference Kumar N, Pison L, Blaauw Y, Timmermans C, La Meir M, Gelsamino S, Crijns H, Maessen J. Pulmonary Vein Stenosis after Laser Balloon Ablation for Atrial Fibrillation. JACC: Clinical Electrophysiology 2015. DOI: 10.1016/j.jacep.2015.04.001. Kumar N, Pison L, Blaauw Y, Timmermans C, La Meir M, Gelsamino S, Crijns H, Maessen J. Pulmonary Vein Stenosis after Laser Balloon Ablation for Atrial Fibrillation. JACC: Clinical Electrophysiology 2015. DOI: 10.1016/j.jacep.2015.04.001.
5.
go back to reference Kumar N, Dinh T, Phan K, Timmermans C, Dassen W, Phillippens S, Vranken N, Pison L, Maessen J, Crijns H. Adenosine Testing after Second generation Cryoballoon Ablation (ATSCA) study improves clinical success rate for atrial fibrillation. Europace. 2015. doi:10.1093/europace/euu352. Kumar N, Dinh T, Phan K, Timmermans C, Dassen W, Phillippens S, Vranken N, Pison L, Maessen J, Crijns H. Adenosine Testing after Second generation Cryoballoon Ablation (ATSCA) study improves clinical success rate for atrial fibrillation. Europace. 2015. doi:10.1093/europace/euu352.
6.
go back to reference Ciconte G, Chierchia GB, DE Asmundis C, Sieira J, Conte G, Julia J, DI Giovanni G, Wauters K, Baltogiannis G, Saitoh Y, Mugnai G, Catanzariti D, Tondo C, Brugada P. Spontaneous and adenosine-induced pulmonary vein reconnection after cryoballoon ablation with the second-generation device. J Cardiovasc Electrophysiol. 2014. doi:10.1111/jce.12421. Ciconte G, Chierchia GB, DE Asmundis C, Sieira J, Conte G, Julia J, DI Giovanni G, Wauters K, Baltogiannis G, Saitoh Y, Mugnai G, Catanzariti D, Tondo C, Brugada P. Spontaneous and adenosine-induced pulmonary vein reconnection after cryoballoon ablation with the second-generation device. J Cardiovasc Electrophysiol. 2014. doi:10.1111/jce.12421.
Metagegevens
Titel
Maastricht experience with the second generation endoscopic laser balloon ablation system for the atrial fibrillation treatment
Auteurs
N. Kumar
M.M. Abbas
R.M.A. Ter Bekke
C.M.M.J.F. de Jong
R. Choudhury
O. Bisht
S. Philippens
C. Timmermans
Publicatiedatum
01-07-2015
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 7-8/2015
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-015-0703-8

Andere artikelen Uitgave 7-8/2015

Netherlands Heart Journal 7-8/2015 Naar de uitgave