Original Article
Precision of Single vs Bilateral Hip Bone Mineral Density Scans

https://doi.org/10.1385/JCD:6:2:159Get rights and content

Abstract

This study was performed to determine and compare the precision of single and bilateral hip bone mineral density (BMD) measurements and to determine the precision of spinal and total body measurements by dual-energy X-ray absorptiometry (DXA). Precision (group root-mean-square average coefficient of variation) was determined in 6 subjects scanned six times each at the spine, both hips, and total body, with repositioning after each scan. Mean percentage coefficients of variance (%CVs) in BMD for single and bilateral hip scans were, respectively: 0.65% and 0.67% for the total hip, 1.16% and 1.03% for the trochanter, and 1.66% and 1.31% for the femoral neck, respectively. Mean %CV was 1.04% for spine BMD (L2–L4), 0.67% for total body BMD, 1.12% for total body bone mineral content (BMC), 0.94% for total body fat tissue, and 0.77% for total body nonfat soft tissue. We conclude that precision overall is excellent and that femoral neck precision can be improved with bilateral compared with the traditional single hip scans.

References (7)

There are more references available in the full text version of this article.

Cited by (39)

  • Cross-Calibration of Prodigy and Horizon A Densitometers and Precision of the Horizon A Densitometer

    2021, Journal of Clinical Densitometry
    Citation Excerpt :

    Precision of this scanner tended to be slightly but not significantly better than the precision of their older Hologic Discovery scanner. The coefficients of variation of BMD measurements on our Horizon A were similar at the femoral neck and spine and slightly higher at the total hip, than values we reported earlier for our Prodigy (14). Abdominal thickness, within the range we studied, did not significantly influence precision or BMD values on the Horizon A scanner.

  • Diet-derived fruit and vegetable metabolites show sex-specific inverse relationships to osteoporosis status

    2021, Bone
    Citation Excerpt :

    BMD was assessed with DXA on a GE-Lunar Model Prodigy scanner (GE Lunar, Madison, WI, USA), with weekly calibration using an external standard (aluminum spine phantom; Lunar Radiation Corp). As reported previously, the root mean square precision was 1.31% and 1.04% for BMD of the femoral neck (FN) and lumbar spine (LS, L2–L4), respectively [26]. The DXA measures were completed using DXA acquisition software version 6.1 and analysis version 12.2.

  • Dietary fat increases vitamin d-3 absorption

    2015, Journal of the Academy of Nutrition and Dietetics
    Citation Excerpt :

    Total body fat tissue mass, a potential storage site for vitamin D, was assessed on the first study visit by a GE Lunar Prodigy dual x-ray absorptiometry scanner with acquisition software version 6.1 (2002) and analysis version 12.2 (2008). The precision of this measure in our laboratory is 0.94%.17 Intake of calcium, macronutrients, and total energy during the past 3 months was assessed on the first study visit with use of a validated Fred Hutchinson food frequency questionnaire.18

View all citing articles on Scopus
View full text