Do patients consider computer-adaptive measures more appropriate than static questionnaires?

A Correction to this article was published on 19 February 2019

This article has been updated

Abstract

Objective

Computer-adaptive tests (CAT) use individualised sets of questions to assess patient-reported health states, whereas static (conventional) questionnaires present the same questions to all patients. CAT has been shown to increase measurement precision and reduce assessment length. In our study, we investigated if patients perceive CAT questions as more appropriate than static questionnaires, a claim that is frequently associated with CAT measures.

Methods

We compared the static European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire Core 30 (EORTC QLQ-C30) against its corresponding CAT measures focusing on two domains: Physical Functioning (PF) and Emotional Functioning (EF). Cancer patients completed the questionnaires and participated in a cognitive interview to assess how appropriate they perceive the QLQ-C30 and the CAT questions for their current health state.

Results

Forty-four cancer patients (mean age = 54.6; 56.8% female) were assessed. For the PF domain, patients considered the CAT items more appropriate (p = 0.002) than the QLQ-C30 items (56.8% vs. 15.9%; 27.2% indifferent). For the EF domain, patients were in favour of the QLQ-C30 items (p < 0.001), with 54.5% considering the QLQ-C30, and 4.5% considering the CAT items to be more appropriate; 40.9% were indifferent. Most patients (N = 36) commented on the preference for the CAT (PF), mentioning better matching of the questions and the health state (38.6%) and better item wording (15.9%).

Conclusion

For the PF domain the CAT measure better matched the score distribution in the patient sample than the QLQ-C30 PF scale and was consequently considered more appropriate by patients. For the EF domain, the CAT measure did not show better fit than the QLQ-C30 and hence no such preference in terms of appropriateness was observed.

Background

In recent years, increasing efforts have been directed towards the incorporation of the patient’s perspective into medical care and research. Today, there is broad consensus on the importance of collecting so-called patient-reported outcomes (PROs), i.e. any report of the status of a patient’s health condition that comes directly from the patient, without interpretation of the patient’s response by a clinician or anyone else [1]. A large number of internationally used and well-validated PRO questionnaires are available for the assessment of various aspects of a patient’s health status such as pain, depression, anxiety, fatigue, or quality of life (QOL) [2].

PRO assessment still mostly relies on traditional questionnaires that present the same set of questions at every assessment to all patients and therefore are frequently referred to as being “static questionnaires”. The use of static PRO measures has shortcomings in terms of measurement precision and length as well as with regard to the comparability of scores across assessment instruments. Static questionnaires mostly are based on classical test theory and require a considerable number of items to cover the whole range of an assessed construct. Consequently, patients may be presented with a high proportion of items inappropriate for their current health state that, at the same time, do not increase measurement precision. For example, a patient who has difficulty taking a short walk will not provide additional information to the clinician or researcher when being asked questions about strenuous sports activities [3]. Moreover, answering such uninformative and inappropriate questions may be frustrating and affect patient compliance with questionnaire completion.

To overcome these limitations, a major focus of current PRO research is the development of computer-adaptive tests (CAT) [3,4,5] based on item response theory (IRT) measurement models. CAT represents a sophisticated form of assessing PROs more precisely by tailoring the questions to the health status of the individual patient. CAT requires an item bank containing a number of IRT-calibrated questions and an algorithm for selecting the most informative questions. A key item characteristic is the so-called item difficulty, a parameter that describes on which part of the measurement continuum an item provides the most information (i.e. has the highest measurement precision) [6]. The CAT algorithm is initiated with a start item and, based on the patient’s first response, calculates a first estimate of the level of the measured PRO. The algorithm then selects an item from the item bank whose item difficulty matches the patient’s construct level and administers this item next. This procedure is repeated until a predefined measurement precision has been reached or a maximum number of items have been asked. By using such tailored sets of items, measurement precision can be increased without increasing completion time.

A CAT version of one of the most widely used cancer-specific QOL questionnaires, the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire Core 30 (EORTC QLQ-C30) [7], has been developed by the EORTC Quality of Life Group (QLG) since 2005 within a series of projects and has been released recently [3, 8, 9]. These projects aimed at constructing item banks for computer-adaptive assessments of 14 out of the 15 functioning and symptom domains covered by the QLQ-C30 (excluding the global QOL scale). By now, several studies [9,10,11] have shown that the new CAT measures are superior to the original QLQ-C30 in terms of measurement precision. While expectations concerning measurement precision and unidimensionality of the item banks have been confirmed in these studies, another frequently claimed advantage of CAT measures has not been investigated so far, neither for the EORTC CAT measures, nor for other CAT measures: the expectation that patients perceive CAT items as more appropriate than items from static questionnaires, since they better match the individual health status.

To investigate this research question, we selected two key domains of the EORTC measurement system, namely physical functioning (PF) and emotional functioning (EF) and compared the static item sets of the QLQ-C30 against the computer-adaptive measures [3, 8, 9, 12] with regard to patients’ perceptions of the appropriateness of the administered questions.

We chose these two domains, as score distributions in the majority of cancer patient groups [13] and the comparison of the measurement precision of the QLQ-C30 and the new CAT item banks [9, 14] indicated that for PF the CAT measures may be superior, in particular in patients with high levels of functioning, whereas for EF no substantial benefit could be expected in well-performing patients.

Therefore, we hypothesised that patients with high levels of functioning would perceive the CAT items to be more appropriate than the QLQ-C30 items for the PF domain, but there would be no difference concerning appropriateness between the two measures for the EF domain.

Patients and methods

Sample and procedure

The study was conducted at a Nuclear Medicine Department. At this department, routine electronic PRO monitoring has been in place since 2011 using the software CHES [15]. The routine assessment comprises the QLQ-C30 and the respective disease specific modules that are completed at the beginning of an inpatient stay. The majority of patients admitted at the department are treated for a diagnosis of thyroid cancer or a neuroendocrine tumour. We approached patients consecutively for study participation in line with the following inclusion criteria:

  • Diagnosis of thyroid cancer or neuroendocrine tumour

  • Sufficient command of German

  • No obvious cognitive impairment

  • Age between 18 and 80 years

  • Participation in routine PRO monitoring

A trained interviewer informed patients about the study objective and procedure. Patients who agreed to participate were assessed with the QLQ-C30 as part of the routine PRO monitoring and completed in addition the EORTC CAT measures for PF and EF. The electronic assessment procedure did not reveal whether an item was part of the QLQ-C30 or of the CAT measure. To elicit the patient’s perspective on the appropriateness of questions, we conducted a cognitive interview within less than one hour after questionnaire completion.

We planned to recruit a minimum number of 30 patients and then continued recruitment until thematic saturation in the cognitive interview had been reached, i.e. no new issues appeared during five subsequent patient interviews. Sociodemographic and clinical data were gathered from the medical charts.

Assessment instruments

EORTC QLQ-C30

The EORTC QLQ-C30 [7] is a widely used cancer-specific QOL questionnaire that can be supplemented with disease-specific modules. It consists of 30 items forming 5 multi-item functioning scales (physical, role, emotional, cognitive, social), 3 multi-item symptom scales (fatigue, nausea/vomiting, pain), 6 single-item symptom scales (dyspnoea, insomnia, appetite loss, constipation, diarrhoea, financial difficulties) and a global QOL scale. Scale scores are derived from summing up item scores followed by linear transformation to a metric from 0 to 100. For the functioning scales high scores indicate good health, whereas for the symptom scales high scores indicate poor health.

EORTC CAT measures for physical and emotional functioning

The item bank for the EORTC PF CAT comprises 31 items [3, 8] and the item bank for the EORTC EF CAT 24 items [9, 12]. All EORTC CAT item banks are designed to measure the same constructs as the corresponding scale of the QLQ-C30 and include all items of this instrument. Scores obtained from EORTC CAT measures are fully backward compatible to scores derived from the QLQ-C30. Backward-compatibility was a key aspect of the development process of the EORTC CAT measures and was ensured for item content and conceptualisation [3, 12] and for dimensionality [8, 9].

In our study, the number of items to be administered in the CAT was set to 5 items for PF and 4 items for EF to equal the number of items in the QLQ-C30 for both domains. The starting items of the CAT measures were according to the expected mean scores of PF and EF in the patient sample. Expected values were estimated using the QLQ-C30 data collected at the department previously within the routine PRO monitoring (mean PF 81 points, mean EF 67 points).

Cognitive interview

We developed a semi-structured interview to assess patients’ perceptions of the appropriateness of the QLQ-C30 and CAT items based on the cognitive interviewing technique (think-aloud sessions) [16] and pilot-tested it for clarity and feasibility in patients at the department. The interview included an explanation of the constructs of PF and EF as assessed within the EORTC measurement system. During the interview, we asked patients to choose which of the two sets of items (QLQ-C30 vs CAT items on PF and EF) they considered to have been more appropriate for their condition. The two item sets were presented as separate lists that did not show whether it were CAT or static items. The interviewer also encouraged patients to give reasons for decisions, thoughts and comments on individual items.

Data analysis

Sample characteristics are provided as means, standard deviations, ranges and absolute and relative frequencies. Item exposure of the CAT items (i.e. the frequency of administration of individual items from the item bank) is given as absolute frequencies. In addition, we provide descriptive statistics for the score distribution of the PF and EF QLQ-C30 scales. The comparison of patients’ appropriateness rating was done using a sign test, a non-parametric test for dependent variables. The impact of sociodemographic characteristics on appropriateness ratings was assessed using the Kruskal-Wallis test for metric and ordinal variables and a Chi-Squared test for nominal variables as appropriate. Furthermore, we investigated whether patients had rated the question set that was psychometrically more informative. To do so, responses were IRT-scored and the information of the QLQ-C30 static question sets and the CAT question sets, respectively, were determined [8, 9]. We calculated the difference in information between the two question sets, and split the sample at the median into a ‘small difference in information group’ and a ‘large difference in information group’ and compared the appropriateness ratings for CAT or the QLQ-C30 respectively in these two groups. The qualitative interview data were categorised by two authors using categories that were set up based on a sample of the interview data. For each domain, we distinguished positive and negative comments on CAT and the QLQ-C30. Results are provided as absolute frequencies per category and with individual patient quotes.

Results

Sample characteristics

In total, 65 eligible patients were approached for study participation. Fourteen patients did not participate due to the following reasons: burden of completing questionnaires (n = 8), not understanding the study purpose (n = 3), technical problems with electronic data capture (n = 2) and concerns on the use of the questionnaire data (n = 1). Of the remaining 51 patients, 7 patients were included in the pilot testing of the cognitive interview and 44 in the main study. Participants in the main study had a mean age of 54.6 years and were mostly women (56.8%). The majority of patients were suffering from thyroid cancer (79.5%). Most common comorbidities according to the Charlson Comorbidity Index [17] were myocardial infarction (6.8%) and previous cancer (4.5%). The vast majority of patients (90.9%) had previous tumour resection (median time since surgery was 8.5 months). Most common medication was thyroid medication (84.1%), antihypertensive medication (36.4%) and psychopharmacological medication (29.5%). See Table 1 for further details on patient characteristics.

Table 1 Sample characteristics (N = 44)

Score distribution and item exposure

For the QLQ-C30 PF scale the median score was 87 points (M = 79.9, SD = 21.0). A ceiling effect of 22.7% (i.e. total score of 100) and no floor effect (i.e. total score of zero) were observed. For the QLQ-C30 EF scale the median score was 67 points (M = 63.4, SD = 27.2) and a ceiling effect of 15.9% and a floor effect of 4.5% were observed. Frequency of patients scoring the top range between 90 and 100 score points was 43.2% for the PF domain and 22.7% for the EF domain.

In total, 220 CAT items were administered for PF (5 items per patient) and 176 for EF (4 items per patient). Analysis of item exposure in the CAT assessments showed that for PF 9.1% (20 out of 220) of all administered items were items from the QLQ-C30. The PF CAT showed a ceiling effect of 6.8% and no floor effect. For EF 27.8% (49 out of 176) of all items administered in the CAT were items from the QLQ-C30. The EF CAT showed a ceiling effect of 15.9% and a floor effect of 2.3%. Details on item exposure are given in Table 2.

Table 2 Item exposure for the Physical Functioning and Emotional Functioning CAT

Appropriateness of the QLQ-C30 and the CAT measures

For PF most patients (56.8%) considered the CAT items to be more appropriate for them than the QLQ-C30 items (p = 0.002), whereas for EF most patients (54.5%) rated the QLQ-C30 items to be more appropriate than the CAT items (p < 0.001). For PF 27.2% and for EF 40.9% of patients were indifferent. For further details, see Table 3.

Table 3 Appropriateness rating CAT vs. QLQ-C30 questions

There was no significant association of age with the appropriateness ratings on the PF domain (p = 0.194). For EF there was a significant association with age (p = 0.038), indicating that patients who were indifferent were older (M = 61.2, SD = 14.6) and patients who rated the QLQ-C30 to be more appropriate were younger (M = 50.0, SD = 13.9). No significant association was observed for sex (PF: p = 0.715, EF: p = 0.886) and education (PF: p = 0.515, EF: p = 0.726).

From a psychometric perspective, CAT provided more information than the QLQ-C30 for all participants (see Table 3). Splitting the sample at the median into a “small difference in information group” and a “large difference in information group” and comparing appropriateness ratings for CAT vs. the QLQ-C30 in these groups revealed that for PF a small difference in information was associated with only small differences in appropriateness ratings (45.5% CAT, 31.8% indifferent, 22.7% QLQ-C30) and a large difference in information was associated with a clearly higher subjective appropriateness of CAT (68.2% CAT, 22.7% indifferent, 9.1% QLQ-C30). For EF it could be shown that when the difference in information was small, the majority of patients (59.1%) were indifferent and when the difference in information was large, the majority (68.2%) rated the QLQ-C30 to be more appropriate (see Table 3).

Qualitative interview results

The cognitive interview data was categorised into positive and negative aspects of the static and of the computer-adaptive measures separately for the PF and for the EF domain. Thirty-six patients provided comments concerning the PF domain and 8 patients commented on the EF domain. For the PF domain, positive aspects of the CAT items mostly related to a better match with the current physical state that required questions on demanding activities (17 patients). In addition, the CAT PF items were considered to be better worded and easier to answer (7 patients). The latter was stated for the QLQ-C30 items by 6 patients. For the EF domain, 3 patients mentioned the CAT items to be too extreme for their current emotional condition, whereas two patients considered them to be highly appropriate. Three patients liked the wording of the QLQ-C30 better. Further details are given in Table 4.

Table 4 Results from cognitive interview think-aloud sessions

Discussion

Our study investigated cancer patients’ perceptions of the appropriateness of questions on PF and EF, comparing the questions from the static EORTC QLQ-C30 against the corresponding CAT measures. We found that patients considered the CAT PF to ask more appropriate questions than the PF items in the QLQ-C30, whereas the opposite was observed for the EF domain, i.e. higher subjective appropriateness of QLQ-C30 items. These effects were especially pronounced in those patients for whom, from a psychometric perspective, the information gained through CAT was large. These findings are well in line with our hypothesis for the PF domain, but not for the EF domain, where we expected more balanced appropriateness ratings of the static and the computer-adaptive questions.

As expected, the QLQ-C30 score distribution was more skewed in the PF domain than in the EF domain. This score distribution (i.e. the non-normal distribution for PF due to ceiling effects) indicates a mismatch of the QLQ-C30 items and the investigated population. This mismatch was also found in the analysis of item exposure where in the CAT assessment of PF the five QLQ-C30 items represented only 9% of all individual items asked. For the EF domain, the score distribution indicated a better spread across the measurement range and therefore a better match of the QLQ-C30 items and the population. In line with this, the EF CAT algorithm selected to a larger degree QLQ-C30 items (28% of the administered items) which indicates that the QLQ-C30 items were among the most informative in this patient group.

For PF the QLQ-C30 asks, for example, about needing assistance for self-care while patients in our sample were more concerned with whether or not being able to perform strenuous sports activities. For the assessment of EF on the other hand, in this patient group the QLQ-C30 items were measuring very well around the sample mean. Apparently in this case the QLQ-C30 static items set for EF often was considered to be more appropriate than CAT EF items. This unexpected finding may have been a result of the fact that the QLQ-C30 items cover core aspects of EF with easy understandably and very familiar expressions for emotional distress. Further, the CAT items mainly concern more severe emotional states than the QLQ-C30, i.e. the far majority of the CAT items are primarily relevant for patients with poorer EF than most patients in the current sample. Had the sample included more patients with low EF scores the appropriateness ratings might have been different. Furthermore, the results on EF suggest that while patients may like simpler items better, particularly for an abstract and complex construct as EF, the simple items may not necessarily be the most informative ones from a psychometric perspective. Hence, it may sometimes be necessary to ask more demanding and potentially semantically distressing questions to obtain the desired knowledge, even though patients may prefer simpler ones.

These differences in preference for PF and EF clearly illustrates that the advantage of CAT and its ability to adapt to the individual depends crucially on that relevant items are available in the item bank. For the current patient sample the PF item bank included several items more relevant than the QLQ-C30, hence the CAT was considered more appropriate, while this was not the case for EF item bank, which may lack items particularly relevant for patients with few emotional problems [9].

Results from the cognitive interviews for PF also emphasise the importance of asking items whose difficulty levels match the patient’s PF level. Furthermore, qualitative results did not indicate relevant differences between QLQ-C30 and CAT PF items with regard to how clearly they were formulated and how easy they were to answer. For the EF domain, patients provided very few comments, which relates to the fact that about 40% were indifferent concerning appropriateness of administered questions for this domain. In addition, it may also reflect that EF is a complex construct and therefore it is intellectually challenging to justify a decision on appropriateness and verbalise arguments.

A limitation of our study is that not all patients were presented the QLQ-C30 items for the first time, as some already had participated in the routine PRO monitoring at the department at previous admissions. This could have resulted in a preference for QLQ-C30 items, since they were familiar to some patients. However, this would affect the PF as well as the EF domain.

While the sample size is not large, it was sufficient to reach thematic saturation in the qualitative part and to demonstrate significant differences with regard to appropriateness ratings. Analysis of the impact of patient characteristics on preference had limited statistical power though. Cognitive interviewing revealed that while patients easily could state a subjective preference for a certain item set, it was very difficult for them to provide explicit justification for their decision. This somewhat limited the fruitfulness of the qualitative part of the interview. It is also important to note, that the CAT has also benefited from a start item that we selected based on previous data collected at the department. Such tailoring is not possible for traditional questionnaires like the QLQ-C30, but for static short-forms based on item banks. The latter can be adapted a priori based on assumptions on score distribution in the target population. This type of IRT-based static questionnaires has been shown to have a measurement precision close to that of CAT measurements [18]and may therefore also be considered to be more appropriate than traditional questionnaires by patients.

Conclusion

In summary, our results support the assumption that questions with a difficulty level that corresponds to the patient’s level of functioning are not only more informative and precise from a psychometric perspective, as demonstrated previously [10, 19, 20], but also perceived as more appropriate by the patient him/herself. This would provide another strong argument for the use of computer-adaptive measures. Larger follow-up studies on the issue investigating other HRQOL domains and other CAT measures are warranted.

Change history

  • 19 February 2019

    Following publication of the original article [1], the authors reported three of their given name have been erroneously tagged as their family names. The correct names are: give name Caroline family name Martini, give name Irene family name Virgolini, give name Bernhard family name Holzner.

Abbreviations

EF:

Emotional Functioning

EORTC :

European Organisation for Research and Treatment of Cancer

IRT:

Item response theory

PF:

Physical Functioning

PROs:

Patient-reported outcomes

QLG:

Quality of Life Group

QLQ-C30 :

Quality of Life Questionnaire Core 30

QOL:

Quality of life

References

  1. U.S. (2009). Food and Drug Administration. In Guidance for industry - patient-reported outcome measures: Use in medical product development to support labeling claims.

    Google Scholar 

  2. Pinotti, R. (2016). PROQOLID. Journal of the Medical Library Association, 104(1), 91–92.

    Article  Google Scholar 

  3. Petersen, M. A., Groenvold, M., Aaronson, N. K., Chie, W. C., Conroy, T., Costantini, A., et al. (2010). Development of computerised adaptive testing (CAT) for the EORTC QLQ-C30 dimensions - general approach and initial results for physical functioning. Eur J Cancer, 46(8), 1352–1358.

    Article  Google Scholar 

  4. Cella, D., Gershon, R., Lai, J.-S., & Choi, S. (2007). The future of outcomes measurement: Item banking, tailored short-forms, and computerized adaptive assessment. Qual Life Res, 16(Suppl 1), 133–141.

    Article  Google Scholar 

  5. Bjorner Jakob, B., Chang, C.-H., Thissen, D., & Reeve Bryce, B. (2007). Developing tailored instruments: Item banking and computerized adaptive assessment. Qual Life Res, 16(Suppl 1), 95–108.

    Article  Google Scholar 

  6. Hambleton, R., Swaminathan, H., & Rogers, H. (1991). Fundamentals of item response theory. Newbury Park: Sage Publications.

    Google Scholar 

  7. Aaronson, N. K., Ahmedzai, S., Bergman, B., Bullinger, M., Cull, A., Duez, N. J., et al. (1993). The European Organization for Research and Treatment of Cancer QLQ-C30: A quality-of-life instrument for use in international clinical trials in oncology. J Natl Cancer Inst, 85(5), 365–376.

    Article  CAS  Google Scholar 

  8. Petersen, M. A., Groenvold, M., Aaronson, N. K., Chie, W. C., Conroy, T., Costantini, A., et al. (2010). Development of computerized adaptive testing (CAT) for the EORTC QLQ-C30 physical functioning dimension. Qual Life Res, 20(4), 479–490.

    Article  Google Scholar 

  9. Petersen, M. A., Gamper, E. M., Costantini, A., Giesinger, J. M., Holzner, B., Johnson, C., et al. (2016). An emotional functioning item bank of 24 items for computerized adaptive testing (CAT) was established. J Clin Epidemiol, 70, 90–100.

    Article  Google Scholar 

  10. Petersen, M. A., Aaronson, N. K., Arraras, J. I., Chie, W. C., Conroy, T., Costantini, A., et al. (2013). The EORTC computer-adaptive tests measuring physical functioning and fatigue exhibited high levels of measurement precision and efficiency. J Clin Epidemiol, 66(3), 330–339.

    Article  Google Scholar 

  11. Petersen, M. A., Aaronson, N. K., Chie, W. C., Conroy, T., Costantini, A., Hammerlid, E., et al. (2016). Development of an item bank for computerized adaptive test (CAT) measurement of pain. Qual Life Res, 25(1), 1–11.

    Article  Google Scholar 

  12. Gamper, E. M., Groenvold, M., Petersen, M. A., Young, T., Costantini, A., Aaronson, N., et al. (2014). The EORTC emotional functioning computerized adaptive test: Phases I-III of a cross-cultural item bank development. Psychooncology, 23(4), 397–403.

    Article  Google Scholar 

  13. Scott, N., Fayers, P., Aaronson, N., Bottomley, A., De Graeff, A., Groenvold, M., et al. (2008). EORTC QLQ-C30 reference values. Brussels: EORTC quality of life Group.

    Google Scholar 

  14. Petersen, M. A., Aaronson Neil, K., Arraras, J., Chie, W. C., Conroy, T., Costantini, A., et al. (2012). The EORTC computer-adaptive tests (CATs) measuring physical functioning and fatigue exhibited high levels of measurement precision and efficiency. In Journal of clinical epidemiology accepted.

    Google Scholar 

  15. Holzner, B., Giesinger, J. M., Pinggera, J., Zugal, S., Schopf, F., Oberguggenberger, A. S., et al. (2012). The computer-based health evaluation system (CHES): A software for electronic patient-reported outcome monitoring. BMC Med Inform Decis Mak, 12(1), 126.

    Article  Google Scholar 

  16. Forsyth, B., & Lessler, J. (1991). Cognitive laboratory methods: A taxonomy. In P. Biemer, R. Groves, L. Lyberg, N. Mathiowetz, & S. Sudman (Eds.), Measurement errors in surveys. New York: Wiley.

    Google Scholar 

  17. Charlson, M. E., Pompei, P., Ales, K. L., & MacKenzie, C. R. (1987). A new method of classifying prognostic comorbidity in longitudinal studies: Development and validation. J Chronic Dis, 40(5), 373–383.

    Article  CAS  Google Scholar 

  18. Choi, S. W., Reise, S. P., Pilkonis, P. A., Hays, R. D., & Cella, D. (2010). Efficiency of static and computer adaptive short forms compared to full-length measures of depressive symptoms. Qual Life Res, 19(1), 125–136.

    Article  Google Scholar 

  19. Rose, M., Bjorner, J. B., Gandek, B., Bruce, B., Fries, J. F., & Ware, J. E., Jr. (2014). The PROMIS physical function item bank was calibrated to a standardized metric and shown to improve measurement efficiency. J Clin Epidemiol, 67(5), 516–526.

    Article  Google Scholar 

  20. Fries, J. F., Krishnan, E., Rose, M., Lingala, B., & Bruce, B. (2011). Improved responsiveness and reduced sample size requirements of PROMIS physical function scales with item response theory. Arthritis Res Ther, 13(5), R147.

    Article  Google Scholar 

Download references

Funding

The work of CM and JMG was funded by a grant from the Austrian Science Fund (FWF; #P26930).

Availability of data and materials

The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

Study design: JMG, EG; Data collection: CM, IV, BH; Statistical analyses: JMG, MP, Manuscript writing: EG, CM, MP; Final approval: JMG, BH, IV. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Johannes M. Giesinger.

Ethics declarations

Ethics approval and consent to participate

The study was conducted according to the principles expressed in the Declaration of Helsinki. It was approved by the Ethics Committee of the Medical University of Innsbruck (reference number: AN2014–0150 336/4.29). Informed consent was obtained from all individual participants included in the study.

Consent for publication

Not applicable.

Competing interests

BH is an owner of the intellectual property rights of the software used for data collection. The other authors declare that they do not have any conflict of interest.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Additional information

The authors reported three of their given name have been erroneously tagged as their family names. The correct names are: give name Caroline family name Martini, give name Irene family name Virgolini, give name Bernhard family name Holzner.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gamper, EM., Martini, C., Petersen, M.A. et al. Do patients consider computer-adaptive measures more appropriate than static questionnaires?. J Patient Rep Outcomes 3, 7 (2019). https://doi.org/10.1186/s41687-019-0096-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s41687-019-0096-3

Keywords