Benefits and risks of manual hyperinflation in intubated and mechanically ventilated intensive care unit patients: a systematic review

Abstract

Introduction

Manual hyperinflation (MH), a frequently applied maneuver in critically ill intubated and mechanically ventilated patients, is suggested to mimic a cough so that airway secretions are mobilized toward the larger airways, where they can easily be removed. As such, MH could prevent plugging of the airways.

Methods

We performed a search in the databases of Medline, Embase, and the Cochrane Library from January 1990 to April 2012. We systematically reviewed the literature on evidence for postulated benefits and risks of MH in critically ill intubated and mechanically ventilated patients.

Results

The search identified 50 articles, of which 19 were considered relevant. We included 13 interventional studies and six observational studies. The number of studies evaluating physiological effects of MH is limited. Trials differed too much to permit meta-analysis. It is uncertain whether MH was applied similarly in the retrieved studies. Finally, most studies are underpowered to show clinical benefit of MH. Use of MH is associated with short-term improvements in lung compliance, oxygenation, and secretion clearance, without changes in outcomes. MH has been reported to be associated with short-term and probably clinically insignificant side effects, including decreases in cardiac output, alterations of heart rates, and increased central venous pressures.

Conclusions

Studies have failed to show that MH benefits critically ill intubated and mechanically ventilated patients. MH is infrequently associated with short-term side effects.

Introduction

Manual hyperinflation (MH), also known as "bagging" or "bag-squeezing" is a frequently used maneuver in critically ill intubated and mechanically ventilated patients [1, 2]. With MH, patients are disconnected from the mechanical ventilator, after which their lungs are temporarily ventilated with a manual ventilation bag. By applying a larger-than-normal volume at a low inspiratory flow followed by an inspiratory pause and expiration with a high expiratory flow, MH is suggested to mimic a normal cough. Propagation of airway secretions from the smaller toward the larger airways then allows for easy removal of airway secretions with airway suction. As such, MH could prevent airway plugging [3, 4], and even promote alveolar recruitment [5].

It is far from certain whether MH truly benefits critically ill intubated and mechanically ventilated patients. In addition, disconnection of a critically ill patient from the ventilator could be seen as a rather unsafe intervention [6]. Because MH may cause short-term hyperinflation, one could even consider MH to be dangerous in hemodynamically unstable patients [7, 8]. Also, MH could be disadvantageous in patients with respiratory failure. The airway pressures at the end of the MH maneuver are usually much lower than the applied level of positive end-expiratory pressure, which, in combination with airway suctioning, may promote atelectasis.

This systematic review aims to collect the evidence for the suggested benefits and risks of MH in critically ill intubated and mechanically ventilated patients. The main research questions were as follows. Does MH benefit critically ill intubated and mechanically ventilated patients with respect to pulmonary compliance, arterial oxygenation, and sputum clearance? Does MH have an effect on the duration of mechanical ventilation, length of stay in the intensive care unit, and incidence of pneumonia? What are reported side effects of MH?

The rationale behind manual hyperinflation

Retained airway secretions may occlude the airways of intubated and mechanically ventilated patients, and, as such, cause atelectasis. This may impair oxygenation by increased intrapulmonary shunting and increase pulmonary vascular resistance. Large atelectasis may even promote development of lung injury [9]. The consequence of large atelectasis is a smaller lung available for ventilation, leading to the concept of "baby lung" ventilation [10]. Persistent presence of sputum in the airways may provide an ideal environment for colonizing organisms, finally resulting in pneumonia [11].

Frequent removal of sputum from the airways via tracheal suctioning is mandatory in critically ill intubated and mechanically ventilated patients. Under normal conditions, mucociliary transport clears the smaller airways of airway secretions. Secretions that are transported from the smaller airways into the bronchi and trachea then are removed by coughing. Critically ill patients, however, are frequently sedated and nursed in a supine position, potentially reducing mucociliary transport and promoting retention of airway secretions [12, 13]. In addition, the cough reflex can be minimal or even absent in sedated critically ill patients, or they may lack force to cough efficiently. Furthermore, sputum may not be easily transported from the trachea into the translaryngeal tube or trachea cannula, and thus could remain in the larger airways. Unfortunately, with airway suctioning, only the trachea is cleared of secretions, as suction catheters cannot reach sputum in the bronchi and smaller airways. MH, as originally described in the late 1960s, was designed to enhance clearance of airway secretions [14].

Description of the MH technique

To enhance the clearance of airway secretions, MH was supposed to include the application of a larger than normal volume (up to one and one half the size of tidal volumes delivered by the ventilator) at a low inspiratory flow (achieved by a slow compression of the ventilation bag), an inspiratory pause (to allow complete distribution of the inflated air among all the ventilated parts of the lung), and a high expiratory flow. In particular, this last element seems important and can be achieved by a complete and rapid release of the ventilation bag [15, 16]. As such, MH could resemble a forceful cough, with which a forced and rapid exhalation follows a deep and slow inhalation.

It is suggested that the effectiveness of MH is dependent, at least in part, on the ratio between flows with inspiration and expiration [3, 4]. With higher expiratory flows (that is, higher than inspiratory flows), sputum could propagate from distal to more proximal areas (that is, from the smaller airways toward the larger airways), where it can be easily removed through endotracheal suctioning [17, 18]. It is also suggested that the use of an inspiratory pause maintains the pressure gradient for an appropriate length of time required to overcome the opening pressure of the alveoli [19].

Materials and methods

Search methods for identification of manuscripts about MH

Two methods were used to identify relevant manuscripts in the medical literature. First, we performed a search in the databases of Medline, Embase, the Cochrane Library, the Cochrane Database of Systematic Reviews, and the Database of Abstracts on Reviews and Effectiveness (DARE) from January 1990 to April 2012 (Additional file 1). Second, reference lists of identified and selected manuscripts were reviewed to identify additional articles.

The following key words (MeSH and text words) were used: "critical care," "intensive care," "manual hyperinflation," "hyperinflation," "bagging," and "bag squeezing." In addition, we used the key words "hyperoxygenation," "physiotherapy," and "physical therapy." We excluded studies of mechanical hyperinflation by machines, like cough-assist devices. The initial search strategy was designed for maximal retrieval, with no limitation on the type of study design to be identified. We used no restriction on language.

Study selection

Two authors (FP and JB) independently reviewed the retrieved articles and abstracts, assessed the eligibility of each study, and resolved disagreement by consensus. Articles were selected if they reported original data from a clinical trial or an observational study. We restricted the selection of articles to those that reported on adult critically ill intubated and mechanically ventilated patients. The same authors made the final selection; we restricted the selection to articles that reported on relevant study end points, including pulmonary compliance, arterial oxygenation, sputum clearance, duration of mechanical ventilation, length of stay in the intensive care unit, and incidence of pneumonia, and only if the main objective concerned the evaluation of the MH procedure.

Data-collection process

We extracted data from the included studies by using a data-extraction sheet. We extracted the following data: characteristics of the studies (design, setting), participants, intervention characteristics (MH technique), comparison intervention, and results of all relevant outcomes.

Assessment of methodologic quality of individual studies

Two reviewers (FP and JB) assessed the risk of bias of the interventional studies and used the categories randomization, random sequence generation allocation concealment, description of withdrawals and dropouts, the method of and use of intention-to-treat analysis, and standardization of important co-interventions.

Synthesis of results

The decision to combine studies in a quantitative analysis was made by assessing clinical heterogeneity (examining types of participants, interventions, and outcomes in each study).

Results

Study selection

The search (Figure 1) identified 50 articles, of which 19 were considered relevant (Tables 1, 2, and 3).

Figure 1
figure 1

Number of articles identified at each stage of the review process for potential inclusion in the systematic review.

Table 1 Studies comparing manual hyperinflation (MH) with standard care
Table 2 Studies comparing manual hyperinflation (MH) with other strategies
Table 3 Side effects of manual hyperinflation (MH)

Study characteristics

We included 13 interventional studies (six randomized controlled trials of MH [5, 20–24], two randomized crossover trials comparing MH with endotracheal suctioning [25, 26], four randomized crossover trials comparing MH with hyperinflation by the mechanical ventilator [27–30], and one randomized crossover trial comparing two different manual-ventilation bags [31]), and six observational studies [7, 8, 32–35]. Physiological end points were respiratory mechanics [20–22, 25, 27–31], arterial oxygenation [5, 20–24, 26–28, 30, 31], and clearance of airway secretions [5, 26, 27, 29–31]. Clinical end points included duration of mechanical ventilation [21, 23], length of stay [21, 23], and incidence of pneumonia [23]. Reported side effects included effects on heart rate and systemic blood pressure [7, 8, 20, 26, 32–34], cardiac output [7, 8, 32, 33, 35], and pulmonary artery pressures and central venous pressures [32, 33, 35].

Risk of bias within studies

The risk of bias among included studies is summarized in Table 4. Quality assessment revealed that five studies did not describe concealment of allocation. Only three studies clearly reported standardization of important co-interventions to prevent performance bias. Most studies did not report the use of intention-to-treat analysis. Description of the losses to follow-up was not included in three studies. All studies were open label, because blinding of the ICU clinicians was not feasible for these types of studies.

Table 4 Summary of risk of bias assessment of the interventional studies

Synthesis of results

Studies varied widely in terms of patient populations, with dissimilar reasons for (acute and/or persistent) intubation and mechanical ventilation, MH intervention, and outcome measurements. Because of the substantial clinical heterogeneity, we focused on describing individual study results, rather than using a meta-analysis.

Physiological end points

The results of the physiological end points for the individual studies are summarized in Figures 2 and 3. We separated studies with an active control group (for example, hyperinflation by the ventilator) from studies comparing MH with standard care.

Figure 2
figure 2

Change in PaO 2 /FiO 2 . These studies compared manual hyperinflation (A) with standard care (B), or manual hyperinflation (C) with other strategies (D), in patients after cardiac surgery [21, 22, 28] (preprocedure data were not reported in [21]), unselected intensive care unit patients [26, 31], patients with atelectasis [5, 27], and patients with acute lung injury [33]. *P < 0.05; **P < 0.001.

Figure 3
figure 3

Change in pulmonary compliance. The studies compared manual hyperinflation (A) with standard care (B), or manual hyperinflation (C) with other strategies (D), in patients after cardiac surgery [21, 22, 28] (preprocedure data were not reported in [21]), unselected intensive care unit patients [26, 29–31], patients with pneumonia [25], patients with atelectasis [27], and patients with acute lung injury [20, 33]. *P < 0.05; **P < 0.001.

MH improved pulmonary compliance in postcardiac surgery patients [21, 22], in patients with pneumonia [25], as well as in patients with large atelectasis [5]. Notably, MH did not improve pulmonary compliance in patients with acute lung injury [20]. With respect to changes in pulmonary compliance, MH was not superior to hyperinflation by the mechanical ventilator [27–30].

MH improved arterial oxygenation in studies of postcardiac surgery patients [21, 22]. However, in another study of postcardiac surgery patients, this could not be confirmed [24], nor in studies of patients with atelectasis [5], nor in a study of brain-injury patients [23]. Notably, although no effect of MH on arterial oxygenation was found in a study of patients with acute lung injury [20], another study found MH to improve arterial oxygenation in patients with indirect acute lung injury but not in patients with direct acute lung injury [7, 33]. MH was not superior to hyperinflation by the mechanical ventilator with respect to arterial oxygenation [27–30].

Although studies of unselected ICU patients found MH to improve sputum clearance [26, 31], this was not found in a study of patients with atelectasis [5]. Similar volumes of pulmonary secretions were mobilized with MH compared with hyperinflation by the mechanical ventilator [27, 29].

Clinical end points

MH was found to shorten the duration of mechanical ventilation in a study of postcardiac surgery patients [21]. This, however, was not confirmed in a study of brain-injury patients [23]. MH did not reduce length of stay in the ICU or hospital, in either postcardiac surgery patients [21] or brain-injury patients [23]. In addition, MH did not reduce the incidence of pneumonia in brain-injury patients [23].

Side effects

The results of the side effects are summarized in Table 3. The majority of studies found MH not to affect systemic blood pressure and heart rate [7, 8, 26, 32, 33]. One study of patients with acute lung injury [20] and one observational study of unselected ICU patients [34] showed MH to increase heart rate and blood pressure, whereas another study in unselected patients showed MH to decrease heart rate [35]. MH was associated with a short-lived 10% to 15% decrease in cardiac output in patients with septic shock as well as in unselected ICU patients [7, 8]. Conversely, this was not found in observational studies of patients with septic shock, patients with acute lung injury, and patients after cardiac surgery [32, 33, 35]. MH was associated with increased central venous pressures in one observational study of patients after cardiac surgery [35]. Side effects were frequently considered clinically irrelevant [7, 8, 20, 34].

Discussion

MH is suggested to mimic a cough so that airway secretions are mobilized from the smaller airways toward the larger airways, where they can easily be removed. As such, MH could benefit critically ill intubated and mechanically ventilated patients. We reviewed studies of diverse intensive care unit populations investigating the potential beneficial effects and side effects of MH. Most investigations consistently showed MH to be feasible and safe. MH improved pulmonary compliance, arterial oxygenation, and clearance of airway secretions, albeit not in all investigations. MH inconsistently affected clinical outcome. Side effects of MH seemed relatively infrequent.

Apart from the possibility that MH may indeed not benefit critically ill intubated and mechanically ventilated patients, studies simply may have been underpowered to detect any beneficial effect of MH, such as duration of mechanical ventilation, length of stay in the intensive care unit, and prevention of ventilator-associated pneumonia.

Studies in this review were heterogeneous in regard to patient populations, MH intervention, and outcome measurements and could not be combined in a meta-analysis. Only a few studies compared MH with standard care. In some studies, MH was compared with another strategy (for example, hyperinflation by the ventilator). Two of the retrieved studies reported the use of position changes in conjunction with MH. Multiple other strategies could have been used in conjunction with MH in other studies, such as postural drainage, vibrations, and manually assisted cough. This, however, was not clearly reported. In addition, most studies included in this review had methodologic flaws, which may have resulted in bias.

Better evidence to support the use of MH is required. Therefore, appropriately powered, well-designed, randomized controlled trials evaluating the effect of MH should be conducted. The focus of these studies should be on clinical end points, including, but not restricted to, duration of mechanical ventilation or ventilator-free days, length of stay in the ICU, and incidence of ventilator-associated pneumonia.

It is difficult to give clear recommendations on how to perform MH maneuvers. Most reports did not adequately describe how MH actually was performed. Monitoring airway pressures is feasible, but may not have priority. Notably, use of larger than normal breaths is associated with higher inspiratory airway pressures, up to 40 ± 8 cm H2O [36, 37]. Also, almost without exception expiratory airway pressures are low, as low as 2.1 [1.4 to 3.1] cm H2O [37]. The most important aspect for MH to be effective may be the high expiratory flow, which can be achieved by rapid and complete release of the ventilation bag [16]. Outside the importance of conducting future studies that comprehensively describe the MH technique used, additional studies could establish how the different components of the technique are of influence on the therapeutic aims of MH.

Unfortunately, MH is frequently referred to as a maneuver to recruit lung tissue. We would like to emphasize that MH was originally designed to mimic a forceful cough. The most important principle for MH to be effective may be the high expiratory flow. Consequently, airway pressures at the end of each MH cycle are low, which may very well promote derecruitment. With the performance of MH, the necessity exists to disconnect the patient from the mechanical ventilator. Breaking the ventilatory circuit may lead to airway contamination and eventually to ventilator-associated pneumonia. Breaking the ventilatory circuit may also lead to significant airway pressure decreases and promote lung derecruitment. Finally, the delivery of larger than normal tidal volumes with MH, even for a very short time, may cause overinflation. Although scientific evidence for the existence of these potential side effects is lacking, they may very well limit adoption of MH. Derecruitment and overinflation could be harmful, especially in patients with acute lung injury, or its more severe form, acute respiratory distress syndrome. It is imaginable that derecruitment and overinflation affect the lungs differently among diverse populations of ICU patients. We suggest that MH may better recruit lung tissue in patients with easy-to-recruit lungs (for example, patients after cardiac surgery or patients with indirect lung injury) than in patients with less compliant lungs (for example, patients with direct lung injury). The dissimilar findings of investigations reviewed here are in line with this suggestion

Future studies should include patients with different pulmonary conditions and should address overinflation and derecruitment with MH. It may be necessary to add recruitment maneuvers to MH, but as far as we know, this has not been the subject of clinical studies.

The retrieved studies reported side effects of MH relatively infrequently, and most of the reported side effects were minor. Because most if not all studies were not specifically designed to detect side effects of MH, absence of reported side effects may not mean that the procedure is necessarily safe.

In a study in which patients showed a small decrease in cardiac output, it was hypothesized that this was caused by a decrease in the cardiac preload [8]. A decrease in cardiac output could therefore depend on the expertise and level of training of ICU nurses and/or respiratory therapists: a (too) large increase of the intrathoracic volume due to a (too) large tidal volume with MH may impede venous return [8, 32]. It has been suggested that MH, when performed under controlled conditions and/or performed by experienced and trained ICU nurses, respiratory therapists, and/or intensivists, has negligible effects on cardiac output [32–34].

Given the paucity of data, one might simply recommend abandoning MH as a relic of good intentions with little scientific evidence, but with potential harm. However, absence of evidence does not necessarily mean evidence of absence. A pathophysiological rationale exists for MH as a secretion-clearance technique that should be tested in clinical trials. From this review of studies ,we conclude that until now, no adequately powered studies tested the hypothesis that MH benefits intubated and mechanically ventilated patients. The same also applies for the potential adverse events of MH.

Limitations exist in the way we conducted our review. First, two of the authors are ICU clinicians and frequent users of the MH procedure and may be potentially biased. Second, electronic and hand searches do not completely reflect the extent of research outcomes; for example, studies presented at congresses are more likely to contain negative reports than are studies reported in the literature. Furthermore, many studies not published in English may not be included in the most commonly used searches.

Conclusions

MH is associated with short-term beneficial effects on lung compliance, oxygenation, and airway clearance in intubated and mechanically ventilated patients. MH is inconsistently associated with clinical benefit. MH only infrequently has been associated with side effects. It should be noted, though, that the majority of published studies were not designed to detect potential adverse events like derecruitment. Appropriately powered and methodologically sound studies of MH are needed before recommendations can be made for routine use of MH.

Key messages

  • Manual hyperinflation is a frequently used maneuver that intends to mimic a forceful cough in critically ill intubated and mechanically ventilated patients.

  • Manual hyperinflation may improve pulmonary compliance, arterial oxygenation, and clearance of airway secretions.

  • As such, manual hyperinflation may benefit intubated and mechanically ventilated critically ill patients.

  • Side effects of manual hyperinflation seem relatively infrequent; however, most studies did not seem to be designed to detect potential adverse effects like derecruitment.

  • Better evidence to support use of manual hyperinflation is required.

Abbreviations

ICU:

intensive care unit

MH:

manual hyperinflation

MV:

mechanical ventilation

P/F:

ratio of partial pressure of arterial oxygen to fraction of inspired oxygen.

References

  1. Hodgson C, Carroll S, Denehy L: A survey of manual hyperinflation in Australian hospitals. Aust J Physiother. 1999, 45: 185-193.

    Article  PubMed  Google Scholar 

  2. Paulus F, Binnekade JM, Middelhoek P, Schultz MJ, Vroom MB: Manual hyperinflation of intubated and mechanically ventilated patients in Dutch intensive care units: a survey into current practice and knowledge. Intensive Crit Care Nurs. 2009, 25: 199-207. 10.1016/j.iccn.2009.04.003.

    Article  PubMed  Google Scholar 

  3. Jones AY: Secretion movement during manual lung inflation and mechanical ventilation. Respir Physiol Neurobiol. 2002, 132: 321-327. 10.1016/S1569-9048(02)00071-X.

    Article  PubMed  Google Scholar 

  4. Kim CS, Iglesias AJ, Sackner MA: Mucus clearance by two-phase gas-liquid flow mechanism: asymmetric periodic flow model. J Appl Physiol. 1987, 62: 959-971.

    PubMed  CAS  Google Scholar 

  5. Maa SH, Hung TJ, Hsu KH, Hsieh YI, Wang KY, Wang CH, Lin HC: Manual hyperinflation improves alveolar recruitment in difficult-to-wean patients. Chest. 2005, 128: 2714-2721. 10.1378/chest.128.4.2714.

    Article  PubMed  Google Scholar 

  6. Lu Q, Capderou A, Cluzel P, Mourgeon E, Abdennour L, Law-Koune JD, Straus C, Grenier P, Zelter M, Rouby JJ: A computed tomographic scan assessment of endotracheal suctioning-induced bronchoconstriction in ventilated sheep. Am J Respir Crit Care Med. 2000, 162: 1898-1904.

    Article  PubMed  CAS  Google Scholar 

  7. Paratz J, Lipman J: Manual hyperinflation causes norepinephrine release. Heart Lung. 2006, 35: 262-268. 10.1016/j.hrtlng.2005.12.002.

    Article  PubMed  Google Scholar 

  8. Singer M, Vermaat J, Hall G, Latter G, Patel M: Hemodynamic effects of manual hyperinflation in critically ill mechanically ventilated patients. Chest. 1994, 106: 1182-1187. 10.1378/chest.106.4.1182.

    Article  PubMed  CAS  Google Scholar 

  9. Duggan M, Kavanagh BP: Pulmonary atelectasis: a pathogenic perioperative entity. Anesthesiology. 2005, 102: 838-854. 10.1097/00000542-200504000-00021.

    Article  PubMed  Google Scholar 

  10. Gattinoni L, Pesenti A: The concept of "baby lung". Intensive Care Med. 2005, 31: 776-784. 10.1007/s00134-005-2627-z.

    Article  PubMed  Google Scholar 

  11. Fahy JV, Dickey BF: Airway mucus function and dysfunction. N Engl J Med. 2010, 363: 2233-2247. 10.1056/NEJMra0910061.

    Article  PubMed  CAS  PubMed Central  Google Scholar 

  12. Dolovich M, Rushbrook J, Churchill E, Mazza M, Powles AC: Effect of continuous lateral rotational therapy on lung mucus transport in mechanically ventilated patients. J Crit Care. 1998, 13: 119-125. 10.1016/S0883-9441(98)90015-6.

    Article  PubMed  CAS  Google Scholar 

  13. Marik PE, Fink MP: One good turn deserves another!. Crit Care Med. 2002, 30: 2146-2148. 10.1097/00003246-200209000-00035.

    Article  PubMed  Google Scholar 

  14. Clement AJ, Hubsch SK: Chest physiotherapy by the 'bag squeezing' method: a guide to technique. Physiotherapy. 1968, 54: 355-359.

    PubMed  CAS  Google Scholar 

  15. Maxwell LJ, Ellis ER: The effect of circuit type, volume delivered and "rapid release" on flow rates during manual hyperinflation. Aust J Physiother. 2003, 49: 31-38.

    Article  PubMed  Google Scholar 

  16. Paulus F, Binnekade JM, Middelhoek P, Vroom MB, Schultz MJ: Feedback and education improve manual hyperinflation maneuvers. Am J Respir Crit Care Med. 2009, 179: A2306-

    Google Scholar 

  17. Ntoumenopoulos G: Mucus on the move: embed it or expel it: the patient, the clinician, and now the ventilator. Respir Care. 2008, 53: 1276-1279.

    PubMed  Google Scholar 

  18. Volpe MS, Adams AB, Amato MB, Marini JJ: Ventilation patterns influence airway secretion movement. Respir Care. 2008, 53: 1287-1294.

    PubMed  Google Scholar 

  19. Rothen HU, Neumann P, Berglund JE, Valtysson J, Magnusson A, Hedenstierna G: Dynamics of re-expansion of atelectasis during general anaesthesia. Br J Anaesth. 1999, 82: 551-556. 10.1093/bja/82.4.551.

    Article  PubMed  CAS  Google Scholar 

  20. Barker M, Adams S: An evaluation of a single chest physiotherapy treatment on mechanically ventilated patients with acute lung injury. Physiother Res Int. 2002, 7: 157-169. 10.1002/pri.252.

    Article  PubMed  Google Scholar 

  21. Blattner C, Guaragna JC, Saadi E: Oxygenation and static compliance is improved immediately after early manual hyperinflation following myocardial revascularisation: a randomised controlled trial. Aust J Physiother. 2008, 54: 173-178. 10.1016/S0004-9514(08)70023-0.

    Article  PubMed  Google Scholar 

  22. Patman S, Jenkins S, Stiller K: Manual hyperinflation: effects on respiratory parameters. Physiother Res Int. 2000, 5: 157-171. 10.1002/pri.196.

    Article  PubMed  CAS  Google Scholar 

  23. Patman S, Jenkins S, Stiller K: Physiotherapy does not prevent, or hasten recovery from, ventilator-associated pneumonia in patients with acquired brain injury. Intensive Care Med. 2009, 35: 258-265. 10.1007/s00134-008-1278-2.

    Article  PubMed  Google Scholar 

  24. Paulus F, Veelo DP, de Nijs SB, Beenen LF, Bresser P, de Mol BA, Binnekade JM, Schultz MJ: Manual hyperinflation partly prevents reductions of functional residual capacity in cardiac surgical patients: a randomized controlled trial 6. Crit Care. 2011, 15: R187-10.1186/cc10340.

    Article  PubMed  PubMed Central  Google Scholar 

  25. Choi JS, Jones AY: Effects of manual hyperinflation and suctioning in respiratory mechanics in mechanically ventilated patients with ventilator-associated pneumonia. Aust J Physiother. 2005, 51: 25-30. 10.1016/S0004-9514(05)70050-7.

    Article  PubMed  Google Scholar 

  26. Hodgson C, Denehy L, Ntoumenopoulos G, Santamaria J, Carroll S: An investigation of the early effects of manual lung hyperinflation in critically ill patients. Anaesth Intensive Care. 2000, 28: 255-261.

    PubMed  CAS  Google Scholar 

  27. Dennis D, Jacob W, Budgeon C: Ventilator versus manual hyperinflation in clearing sputum in ventilated intensive care unit patients 4. Anaesth Intensive Care. 2012, 40: 142-149.

    PubMed  Google Scholar 

  28. Ahmed F, Shafeeq AM, Moiz JA, Geelani MA: Comparison of effects of manual versus ventilator hyperinflation on respiratory compliance and arterial blood gases in patients undergoing mitral valve replacement. Heart Lung. 2010, 39: 437-443. 10.1016/j.hrtlng.2009.10.006.

    Article  PubMed  Google Scholar 

  29. Berney S, Denehy L: A comparison of the effects of manual and ventilator hyperinflation on static lung compliance and sputum production in intubated and ventilated intensive care patients. Physiother Res Int. 2002, 7: 100-108. 10.1002/pri.246.

    Article  PubMed  Google Scholar 

  30. Savian C, Paratz J, Davies A: Comparison of the effectiveness of manual and ventilator hyperinflation at different levels of positive end-expiratory pressure in artificially ventilated and intubated intensive care patients. Heart Lung. 2006, 35: 334-341. 10.1016/j.hrtlng.2006.02.003.

    Article  PubMed  Google Scholar 

  31. Hodgson C, Ntoumenopoulos G, Dawson H, Paratz J: The Mapleson C circuit clears more secretions than the Laerdal circuit during manual hyperinflation in mechanically ventilated patients: a randomised cross-over trial. Aust J Physiother. 2007, 53: 33-38. 10.1016/S0004-9514(07)70059-4.

    Article  PubMed  Google Scholar 

  32. Jellema WT, Groeneveld AB, van GJ, Wesseling KH, Westerhof N, Lubbers MJ, Kesecioglu J, van Lieshout JJ: Hemodynamic effects of intermittent manual lung hyperinflation in patients with septic shock. Heart Lung. 2000, 29: 356-366. 10.1067/mhl.2000.109697.

    Article  PubMed  CAS  Google Scholar 

  33. Paratz J, Lipman J, McAuliffe M: Effect of manual hyperinflation on hemodynamics, gas exchange, and respiratory mechanics in ventilated patients. J Intensive Care Med. 2002, 17: 317-324. 10.1177/0885066602238034.

    Article  Google Scholar 

  34. Paulus F, Binnekade JM, Vermeulen M, Vroom MB, Schultz MJ: Manual hyperinflation is associated with a low rate of adverse events when performed by experienced and trained nurses in stable critically ill patients: a prospective observational study. Minerva Anestesiol. 2010, 76: 1036-1042.

    PubMed  CAS  Google Scholar 

  35. Patman S, Jenkins S, Bostock S, Edin S: Cardiovascular responses to manual hyperinflation in post-operative coronary artery surgery patients. Physiother Theory Pract. 1998, 14: 5-12. 10.3109/09593989809070039.

    Article  Google Scholar 

  36. Patman S, Jenkins S, Smith K: Manual hyperinflation: consistency and modification of the technique by physiotherapists. Physiother Res Int. 2001, 6: 106-117. 10.1002/pri.219.

    Article  PubMed  CAS  Google Scholar 

  37. Paulus F, Binnekade JM, Middelhoek P, Vroom MB, Schultz MJ: Performance of manual hyperinflation: a skills lab study among trained intensive care unit nurses. Med Sci Monit. 2009, 15: CR418-CR422.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Frederique Paulus.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors' contributions

FP and JMB performed the literature search and selected the relevant articles for inclusion independently. FP and JMB reviewed the selected articles. FP and JMB wrote the initial draft of the manuscript. MJS contributed to the interpretation of the results and drafting of the manuscript. MBV and MJS critically revised the manuscript. All authors read and approved the manuscript for publication.

Electronic supplementary material

13054_2011_726_MOESM1_ESM.DOC

Additional file 1: Search method. A summary of search strategy and search terms for the identification of articles with MH. (DOC 30 KB)

Authors’ original submitted files for images

Rights and permissions

Reprints and permissions

About this article

Cite this article

Paulus, F., Binnekade, J.M., Vroom, M.B. et al. Benefits and risks of manual hyperinflation in intubated and mechanically ventilated intensive care unit patients: a systematic review. Crit Care 16, R145 (2012). https://doi.org/10.1186/cc11457

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/cc11457

Keywords