Abstract
The use of optical radiation in the so-called light-assisted tooth bleaching procedures has been suggested to enhance the oxidizing effect of the bleaching agent, hydrogen peroxide. Documentation is scarce on the potential adverse effects of bleaching products and on optical exposure risks to eyes and skin. The efficacy of seven bleaching products with or without simultaneous use of seven different bleaching lamps was investigated using extracted human teeth. The bleaching effect was determined immediately after treatment and one week later. Tooth surfaces were examined for adverse alterations after bleaching using a scanning electron microscope. Source characteristics of eight lamps intended for tooth bleaching were determined. International guidelines on optical radiation were used to assess eye and skin exposure hazards due to UV and visible light emission from the lamps. Inspection of teeth one week after bleaching showed no difference in efficacy between teeth bleached with or without irradiation for any of the products. Scratches, probably from the cleaning procedure were frequently seen on bleached enamel irrespective of irradiation. Maximum permissible exposure time (tmax) and threshold limit values were exceeded for about half the bleaching lamps investigated. One lamp exceeded tmax even for reflected blue light within the treatment time. This lamp also exceeded tmax values for UV exposure. The lamps were classified as “low risk” and as borderline to “moderate risk” according to a relevant lamp standard.
Similar content being viewed by others
Notes and references
A. Joiner, The bleaching of teeth: a review of the literature, J. Dent., 2006, 34, 412–419.
V. B. Haywood and H. O. Heymann, Nightguard vital bleaching, Quintessence Int., 1989, 20, 173–176.
R. A. Feinman, R. E. Goldstein and D. A. Garber, Bleaching teeth, Quintessence, Chicago, 1987.
J. E. Dahl and U. Pallesen, Tooth bleaching–a critical review of the biological aspects, Crit. Rev. Oral Biol. Med., 2003, 14, 292–304.
M. Tavares, J. Stultz, M. Newman, V. Smith, R. Kent, E. Carpino and J. M. Goodson, Light augments tooth whitening with peroxide, J. Am. Dent. Assoc., 2003, 134, 167–175.
W. Buchalla and T. Attin, External bleaching therapy with activation by heat, light or laser–a systematic review, Dent. Mater., 2007, 23, 586–596.
C. F. Pinto, R. Oliveira, V. Cavalli and M. Giannini, Peroxide bleaching agent effects on enamel surface microhardness, roughness and morphology, Braz. Oral Res., 2004, 18, 306–311.
B. Fu, W. Hoth-Hannig and M. Hannig, Effects of dental bleaching on micro- and nano-morphological alterations of the enamel surface, Am. J. Dent., 2007, 20, 35–40.
H. Moseley, R. Strang and I. MacDonald, Evaluation of the risk associated with the use of blue light polymerizing sources, J. Dent., 1987, 15, 12–15.
W. T. Ham, Jr., The photopathology and nature of the blue-light and near-UV retinal lesion produced by lasers and other optical sources, in Laser Applications in Medicine and Biology, ed. M. L. Wolbarsht, Plenum Press, New York, 1989, pp. 191–246.
B. R. Sperber, H. W. Walling, C. J. Arpey and D. C. Whitaker, Vesiculobullous eruption from intense pulsed light treatment, Dermatol. Surg., 2005, 31, 345–348.
A. J. Swerdlow, J. S. English, R. M. MacKie, C. J. O’Doherty, J. A. Hunter, J. Clark and D. J. Hole, Fluorescent lights, ultraviolet lamps, and risk of cutaneous melanoma, BMJ, 1988, 297, 647–650.
American Conference of Governmental Industrial Hygienists (ACGIH), TLVs® and BEIs®, Ultraviolet radiation, ACGIH, Cincinnati, 2007, pp. 146–149.
International Commission on Non-Ionizing Radiation Protection (ICNIRP), Guidelines on limits of exposure to ultraviolet radiation of wavelengths between 180 nm and 400 nm (incoherent optical radiation), Health Phys., 2004, 87, 171–186.
F. Grum and R. J. Becherer, Radiometry, Academic Press, New York, 1979, vol. 1,p. 40.
E. M. Bruzell, B. Johnsen, T. N. Aalerud and T. Christensen, Evaluation of eye protection filters for use with dental curing and bleaching lamps, J. Occup. Environ. Hyg., 2007, 4, 432–439.
International Commission on Non-Ionizing Radiation Protection (ICNIRP), Guidelines on Limits of Exposure to Broad-Band Incoherent Optical Radiation (0.38 to 3 μm), Health Phys., 1997, 73, 539–554.
American Conference of Governmental Industrial Hygienists (ACGIH), TLVs® and BEIs®, Light and near-infrared radiation, ACGIH, Cincinnati, 2007, pp. 133–145.
International Commission on Illumination (CIE), Photobiological Safety of Lamps and Lamp Systems, CIE S 009/E:2002, Vienna, 2002.
Fig. 1 and 2 are previously published in the following Scandinavian journal and report as well as at a European congress: E. Bruzell and J. E. Dahl, Assessment of light-assisted tooth bleaching, Nor. Tannlaegeforen. Tid., 2006, 116, 616–621, available at (July 2008) http://www.tannlegetidende.no/pls/dntt/pa_dtdm.xpnd?vp_seks_id=207644&b_start=1, in Norwegian with English summary
E. M. Bruzell and J. E. Dahl, Tandblekning med och utan ljus, Kunskapscenter för Dentala Material Report no. 2006-123-43, Socialstyrelsen, Stockholm, 2006, available at (July 2008) http://www.socialstyrelsen.se/Publicerat/2006/9355/2006-123-43.htm, in Swedish E. Bruzell and J. E. Dahl, presented in part at the 12th Congress of the European Society for Photobiology, Bath, England, September 2007. The material is published with the permission from the owners of the original data
C. Zantner, F. Derdilopoulou, P. Martus and A. M. Kielbassa, Randomized clinical trial on the efficacy of 2 over-the-counter whitening systems, Quintessence Int., 2006, 37, 695–706.
S. Ho and A. C. Goerig, An in vitro comparison of different bleaching agents in the discolored tooth, J. Endod., 1989, 15, 106–111.
M. Sulieman, E. MacDonald, J. S. Rees and M. Addy, Comparison of three in-office bleaching systems based on 35% hydrogen peroxide with different light activators, Am. J. Dent., 2005, 18, 194–197.
L. D. Carrasco, D. M. Guerisoli, M. J. Rocha, J. D. Pecora and I. C. Froner, Efficacy of intracoronal bleaching techniques with different light activation sources, Int. Endod. J., 2007, 40, 204–208.
D. Dietschi, S. Rossier and I. Krejci, In vitro colorimetric evaluation of the efficacy of various bleaching methods and products, Quintessence Int., 2006, 37, 515–526.
A. Papathanasiou, S. Kastali, R. D. Perry and G. Kugel, Clinical evaluation of a 35% hydrogen peroxide in-office whitening system, Compend. Contin. Educ. Dent., 2002, 23, 335–346.
Clinical Research Associates, New generation in-office vital tooth bleaching, part 1, CRA Newsletter, 2002, 26, 1–3.
Clinical Research Associates, New generation in-office vital tooth bleaching, part 2, CRA Newsletter, 2003, 27, 1–3.
Clinical Research Associates, In-office tooth lightening - 1-year recall, CRA Newsletter, 2004, 28, 1–2.
D. K. Hein, B. J. Ploeger, J. K. Hartup, R. S. Wagstaff, T. M. Palmer and L. D. Hansen, In-office vital tooth bleaching–what do lights add?, Compend. Contin. Educ. Dent., 2003, 24, 340–352.
K. Luk, L. Tam and M. Hubert, Effect of light energy on peroxide tooth bleaching, J. Am. Dent. Assoc., 2004, 135, 194–201.
L. M. Justino, D. R. Tames and F. F. Demarco, In situ and in vitro effects of bleaching with carbamide peroxide on human enamel, Oper. Dent., 2004, 29, 219–225.
R. T. Basting, A. L. Rodrigues, Jr. and M. C. Serra, The effect of 10% carbamide peroxide, carbopol and/or glycerin on enamel and dentin microhardness, Oper. Dent., 2005, 30, 608–616.
B. R. Hairul Nizam, C. T. Lim, H. K. Cheng and A. U. Yap, Nanoindentation study of human premolars subjected to bleaching agent, J. Biomech., 2005, 38, 2204–2211.
J. A. Rodrigues, G. M. Marchi, G. M. Ambrosano, H. O. Heymann and L. A. Pimenta, Microhardness evaluation of in situ vital bleaching on human dental enamel using a novel study design, Dent. Mater., 2005, 21, 1059–1067.
J. J. Faraoni-Romano, C. P. Turssi and M. C. Serra, Concentration-dependent effect of bleaching agents on microhardness and roughness of enamel and dentin, Am. J. Dent., 2007, 20, 31–34.
European Committee for Standardization (CEN), Measurement and assessment of personal exposures to incoherent optical radiation. Ultraviolet radiation emitted by artificial sources in the workplace, EN 14255-1:2005, CEN, Brussels, 2005.
Act and Regulations on Radiation Protection and Use of Radiation of 12-5-2000, Medical Use of Radiation/36, I-1094 B, Ministry of Health and Care Services (Norway), Oslo, 2000, ch. 40.
H. Diffey and G. Hart, Ultraviolet and blue-light phototherapy - Principles, sources, dosimetry and safety, Institute of Physics and Engineering in Medicine (IPEM) Report 76, IPEM, York, 1997, p. 37.
D. H. Sliney, Ultraviolet radiation effects upon the eye: Problems of dosimetry, Radiat. Prot. Dosimetry, 1997, 72, 197–206.
E. M. Bruzell Roll, N. Jacobsen and A. Hensten-Pettersen, Health hazards associated with curing light in the dental clinic, Clin. Oral Investig., 2004, 8, 113–117.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bruzell, E.M., Johnsen, B., Aalerud, T.N. et al. In vitro efficacy and risk for adverse effects of light-assisted tooth bleaching. Photochem Photobiol Sci 8, 377–385 (2009). https://doi.org/10.1039/b813132e
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1039/b813132e