Hostname: page-component-8448b6f56d-c47g7 Total loading time: 0 Render date: 2024-04-20T02:46:13.587Z Has data issue: false hasContentIssue false

Live 3D image overlay for arterial duct closure with Amplatzer Duct Occluder II additional size

Published online by Cambridge University Press:  11 September 2015

Sebstian Goreczny*
Affiliation:
Department of Cardiology, Research Institute, Polish Mother’s Memorial Hospital, Lodz, Poland
Gareth J. Morgan
Affiliation:
Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas’ NHS Foundation Trust, London, United Kingdom
Pawel Dryzek
Affiliation:
Department of Cardiology, Research Institute, Polish Mother’s Memorial Hospital, Lodz, Poland
*
Correspondence to: S. Goreczny, MD, PhD, Department of Cardiology, Research Institute, Polish Mother’s Memorial Hospital, Rzgowska Street 281/289, 93-347 Lodz, Poland. Tel: +48422711478; Fax: +48422711470; E-mail: sebastiangoreczny@yahoo.pl

Abstract

Despite several reports describing echocardiography for the guidance of ductal closure, two-dimensional angiography remains the mainstay imaging tool; three-dimensional rotational angiography has the potential to overcome some of the drawbacks of standard angiography, and reconstructed image overlay provides reliable guidance for device placement. We describe arterial duct closure solely from venous approach guided by live three-dimensional image overlay.

Type
Brief Reports
Copyright
© Cambridge University Press 2015 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Dryzek, P, Goreczny, S, Kopala, M. Interventional treatment of critical coarctation of the aorta in an extremely low birth weight preterm neonate. Cardiol Young 2012; 22: 475477.CrossRefGoogle Scholar
2. Stumper, O, Ramchandani, B, Noonan, P, et al. Stenting of the right ventricular outflow tract. Heart 2013; 99: 16031608.CrossRefGoogle ScholarPubMed
3. Pushparajah, K, Hayes, N, Durward, A, Qureshi, S, Austin, CB, Rosenthal, E. Stenting the atrial septum: a hybrid approach guided solely by echocardiography. J Card Surg 2014; 29: 561563.CrossRefGoogle ScholarPubMed
4. Forsey, J, Kenny, D, Morgan, G, et al. Early clinical experience with the new Amplatzer Ductal Occluder II for closure of the persistent arterial duct. Catheter Cardiovasc Interv 2009; 74: 615623.CrossRefGoogle ScholarPubMed
5. Kenny, D, Morgan, GJ, Bentham, JR, et al. Early clinical experience with a modified Amplatzer ductal occluder for transcatheter arterial duct occlusion in infants and small children. Catheter Cardiovasc Interv 2013; 82: 534540.CrossRefGoogle ScholarPubMed
6. Bentham, J, Meur, S, Hudsmith, L, Archer, N, Wilson, N. Echocardiographically guided catheter closure of arterial ducts in small preterm infants on the neonatal intensive care unit. Catheter Cardiovasc Interv 2011; 77: 409415.CrossRefGoogle ScholarPubMed
7. Zahn, EM, Nevin, P, Simmons, C, Garg, R. A novel technique for transcatheter patent ductus arteriosus closure in extremely preterm infants using commercially available technology. Catheter Cardiovasc Interv 2015; 85: 240248.CrossRefGoogle ScholarPubMed
8. Glöckler, M, Halbfaβ, J, Koch, A, Achenbach, S, Dittrich, S. Multimodality 3D-roadmap for cardiovascular interventions in congenital heart disease – a single-center, retrospective analysis of 78 cases. Catheter Cardiovasc Interv 2013; 82: 436442.CrossRefGoogle ScholarPubMed
9. Rigatelli, G, Zamboni, A, Cardaioli, P. Three-dimensional rotational digital angiography in a complicated case of patent ductus arteriosus transcatheter closure. Catheter Cardiovasc Interv 2007; 70: 900903.CrossRefGoogle Scholar
10. Baykan, A, Narin, N, Ozyurt, A, et al. Do we need a femoral artery route for transvenous PDA closure in children with ADO-I? Anatol J Cardiol 2015; 15: 242247.CrossRefGoogle Scholar

Goreczny supplementary material

Movie S1

Download Goreczny supplementary material(Video)
Video 3.1 MB

Goreczny supplementary material

Movie S2

Download Goreczny supplementary material(Video)
Video 9.1 MB