Noninvasive imaging in the evaluation of a wide variety of cardiovascular diseases has gained an increasing role in the diagnostic strategy in current cardiology practice [14]. This holds in particular for patients with myocardial ischaemia due to coronary artery disease (CAD) [57]. Of the present imaging modalities, single-photon emission computed tomography (SPECT), positron emission tomography (PET) and cardiac magnetic resonance (CMR) have attained a major position when it comes to myocardial perfusion imaging [812].
In the May 2012 issue of the Journal of the American College of Cardiology (JACC), Jaarsma et al. [13] from Maastricht University Medical Center evaluated the diagnostic accuracy of SPECT, PET and CMR for the diagnosis of obstructive CAD. Studies published between 1990 and 2010 identified by PubMed search and citation tracking were examined. A study was included if a perfusion imaging modality was used as a diagnostic test for the detection of obstructive CAD and coronary angiography as the reference standard (50 % diameter luminal stenosis).
Out of a total of 3635 studies, 166 articles (including 17,901 patients) met the inclusion criteria: 114 SPECT, 37 CMR, and 15 PET studies. There were insufficient publications on perfusion echocardiography and computed tomography to include these modalities in the study. Patient-based analysis per imaging modality demonstrated pooled sensitivities of 88 % for SPECT, 84 % for PET , and 89 % for CMR; pooled specificities were 61 %, 81 %, and 76 %, respectively.
The authors concluded that SPECT, PET, and CMR all yielded high sensitivities, whereas a broad range of specificities were observed. CMR and especially PET showed a significantly higher diagnostic accuracy than SPECT. However, SPECT is more widely available, less expensive, and most extensively validated. In addition, the use of attenuation programs improved the specificity of SPECT. CMR may provide a valid alternative without ionising radiation to the nuclear imaging methods. The authors suggested that referring physicians should consider these findings in the context of local expertise and internal logistics.
The authors should be complimented for performing this impressive research. It is the first meta-analysis that has directly compared the three most commonly used techniques for myocardial perfusion imaging, i.e. SPECT, PET, and CMR. The present study emphasises that, from a clinical perspective, each of the studied imaging modalities is in principle suited for detection of abnormalities in myocardial perfusion imaging [14]. As always, selective use is mostly dependent on the institutional availability of the imaging device(s), familiarity with the technique, and the individual expert knowledge of the treating physician [15].

Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Onze productaanbevelingen

Netherlands Heart Journal

Het Netherlands Heart Journal wordt uitgegeven in samenwerking met de Nederlandse Vereniging voor Cardiologie en de Nederlandse Hartstichting. Het tijdschrift is Engelstalig en wordt gratis beschikbaa ...

Literatuur
1.
go back to reference Rebergen SA, Ottenkamp J, Doornbos J, van der Wall EE, Chin JG, de Roos A. Postoperative pulmonary flow dynamics after Fontan surgery: assessment with nuclear magnetic resonance velocity mapping. J Am Coll Cardiol. 1993;21:123–31.PubMedCrossRef Rebergen SA, Ottenkamp J, Doornbos J, van der Wall EE, Chin JG, de Roos A. Postoperative pulmonary flow dynamics after Fontan surgery: assessment with nuclear magnetic resonance velocity mapping. J Am Coll Cardiol. 1993;21:123–31.PubMedCrossRef
2.
go back to reference Henneman MM, Schuijf JD, Pundziute G, et al. Noninvasive evaluation with multislice computed tomography in suspected acute coronary syndrome: plaque morphology on multislice computed tomography versus coronary calcium score. J Am Coll Cardiol. 2008;52:216–22.PubMedCrossRef Henneman MM, Schuijf JD, Pundziute G, et al. Noninvasive evaluation with multislice computed tomography in suspected acute coronary syndrome: plaque morphology on multislice computed tomography versus coronary calcium score. J Am Coll Cardiol. 2008;52:216–22.PubMedCrossRef
3.
go back to reference Groenink M, Lohuis TA, Tijssen JG, et al. Survival and complication free survival in Marfan’s syndrome: implications of current guidelines. Heart. 1999;82:499–504.PubMed Groenink M, Lohuis TA, Tijssen JG, et al. Survival and complication free survival in Marfan’s syndrome: implications of current guidelines. Heart. 1999;82:499–504.PubMed
4.
go back to reference Van de Veire NR, Schuijf JD, De Sutter J, et al. Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography. J Am Coll Cardiol. 2006;48:1832–8.PubMedCrossRef Van de Veire NR, Schuijf JD, De Sutter J, et al. Non-invasive visualization of the cardiac venous system in coronary artery disease patients using 64-slice computed tomography. J Am Coll Cardiol. 2006;48:1832–8.PubMedCrossRef
5.
go back to reference Bleeker GB, Mollema SA, Holman ER, et al. Left ventricular resynchronization is mandatory for response to cardiac resynchronization therapy: analysis in patients with echocardiographic evidence of left ventricular dyssynchrony at baseline. Circulation. 2007;116:1440–8.PubMedCrossRef Bleeker GB, Mollema SA, Holman ER, et al. Left ventricular resynchronization is mandatory for response to cardiac resynchronization therapy: analysis in patients with echocardiographic evidence of left ventricular dyssynchrony at baseline. Circulation. 2007;116:1440–8.PubMedCrossRef
6.
go back to reference van der Wall EE, Heidendal GA, den Hollander W, Westera G, Roos JP. Metabolic myocardial imaging with 123I-labeled heptadecanoic acid in patients with angina pectoris. Eur J Nucl Med. 1981;6:391–6.PubMed van der Wall EE, Heidendal GA, den Hollander W, Westera G, Roos JP. Metabolic myocardial imaging with 123I-labeled heptadecanoic acid in patients with angina pectoris. Eur J Nucl Med. 1981;6:391–6.PubMed
7.
go back to reference de Roos A, Doornbos J, van der Wall EE, van Voorthuisen AE. MR imaging of acute myocardial infarction: value of Gd-DTPA. AJR Am J Roentgenol. 1988;150:531–4.PubMed de Roos A, Doornbos J, van der Wall EE, van Voorthuisen AE. MR imaging of acute myocardial infarction: value of Gd-DTPA. AJR Am J Roentgenol. 1988;150:531–4.PubMed
8.
go back to reference van der Wall EE, Vliegen HW, de Roos A, Bruschke AV. Magnetic resonance imaging in coronary artery disease. Circulation. 1995;92:2723–39.PubMedCrossRef van der Wall EE, Vliegen HW, de Roos A, Bruschke AV. Magnetic resonance imaging in coronary artery disease. Circulation. 1995;92:2723–39.PubMedCrossRef
9.
go back to reference Matheijssen NA, Louwerenburg HW, van Rugge FP, et al. Comparison of ultrafast dipyridamole magnetic resonance imaging with dipyridamole SestaMIBI SPECT for detection of perfusion abnormalities in patients with one-vessel coronary artery disease: assessment by quantitative model fitting. Magn Reson Med. 1996;35:221–8.PubMedCrossRef Matheijssen NA, Louwerenburg HW, van Rugge FP, et al. Comparison of ultrafast dipyridamole magnetic resonance imaging with dipyridamole SestaMIBI SPECT for detection of perfusion abnormalities in patients with one-vessel coronary artery disease: assessment by quantitative model fitting. Magn Reson Med. 1996;35:221–8.PubMedCrossRef
10.
go back to reference Kirschbaum SW, de Feyter PJ, van Geuns RJ. Cardiac magnetic resonance imaging in stable ischaemic heart disease. Neth Heart J. 2011;19:229–35.PubMedCrossRef Kirschbaum SW, de Feyter PJ, van Geuns RJ. Cardiac magnetic resonance imaging in stable ischaemic heart disease. Neth Heart J. 2011;19:229–35.PubMedCrossRef
11.
go back to reference Olimulder MA, Galjee MA, van Es J, Wagenaar LJ, von Birgelen C. Contrast-enhancement cardiac magnetic resonance imaging beyond the scope of viability. Neth Heart J. 2011;19:236–45.PubMedCrossRef Olimulder MA, Galjee MA, van Es J, Wagenaar LJ, von Birgelen C. Contrast-enhancement cardiac magnetic resonance imaging beyond the scope of viability. Neth Heart J. 2011;19:236–45.PubMedCrossRef
12.
go back to reference Underwood SR, Bax JJ, vom Dahl J, et al. Study Group of the European Society of Cardiology. Imaging techniques for the assessment of myocardial hibernation. Report of a Study Group of the European Society of Cardiology. Eur Heart J. 2004;25:815–36.PubMedCrossRef Underwood SR, Bax JJ, vom Dahl J, et al. Study Group of the European Society of Cardiology. Imaging techniques for the assessment of myocardial hibernation. Report of a Study Group of the European Society of Cardiology. Eur Heart J. 2004;25:815–36.PubMedCrossRef
13.
go back to reference Jaarsma C, Leiner T, Bekkers SC, et al. Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography Imaging for the detection of obstructive coronary artery disease: a meta-analysis. J Am Coll Cardiol. 2012;59:1719–28.PubMedCrossRef Jaarsma C, Leiner T, Bekkers SC, et al. Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography Imaging for the detection of obstructive coronary artery disease: a meta-analysis. J Am Coll Cardiol. 2012;59:1719–28.PubMedCrossRef
14.
go back to reference Groothuis JG, Beek AM, Meijerink MR, Brinckman SL, Hofman MB, van Rossum AC. Towards a noninvasive anatomical and functional diagnostic work-up of patients with suspected coronary artery disease. Neth Heart J. 2010;18:270–3.PubMedCrossRef Groothuis JG, Beek AM, Meijerink MR, Brinckman SL, Hofman MB, van Rossum AC. Towards a noninvasive anatomical and functional diagnostic work-up of patients with suspected coronary artery disease. Neth Heart J. 2010;18:270–3.PubMedCrossRef
15.
go back to reference Lexis CP, Rahel BM, van Langen H, et al. Cardiac magnetic resonance imaging in daily practice in a peripheral medical centre: description of the first 383 patients. Neth Heart J. 2010;18:524–30.PubMedCrossRef Lexis CP, Rahel BM, van Langen H, et al. Cardiac magnetic resonance imaging in daily practice in a peripheral medical centre: description of the first 383 patients. Neth Heart J. 2010;18:524–30.PubMedCrossRef
Metagegevens
Titel
Myocardial perfusion imaging in coronary artery disease: SPECT, PET or CMR?
Auteur
E. E. van der Wall
Publicatiedatum
01-08-2012
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 7-8/2012
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/s12471-012-0300-z

Andere artikelen Uitgave 7-8/2012

Netherlands Heart Journal 7-8/2012 Naar de uitgave