Skip to main content
Top
Gepubliceerd in: Quality of Life Research 5/2019

Open Access 27-11-2018

Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation

Auteurs: A. Q. Summerfield, G. R. Barton, the UK Cochlear Implant Study Group

Gepubliceerd in: Quality of Life Research | Uitgave 5/2019

Abstract

Purpose

There is concern that some generic preference-based measures (GPMs) of health-related quality of life may be insensitive to interventions that improve hearing. Establishing where sensitivity arises could contribute to the design of improved measures. Accordingly, we compared the sensitivity of four widely used GPMs to a clinically effective treatment—cochlear implantation—which restores material degrees of hearing to adults with little or no functional hearing.

Methods

Participants (N = 147) received implants in any of 13 hospitals in the UK. One month before implantation and 9 months after, they completed the HUI2, HUI3, EQ5D3L, and SF-6D questionnaires, together with the EuroQoL visual-analogue scale as a direct measure of health, a performance test of speech reception, and a self-report measure of annoyance due to tinnitus.

Results

Implantation was associated with a large improvement in speech reception and a small improvement in tinnitus. HUI2 and HUI3 were sensitive to the improvement in speech reception through their Sensation and Hearing dimensions; EQ5D3L was sensitive to the improvement in tinnitus through its Anxiety/Depression dimension; SF-6D was sensitive to neither. Participants reported no overall improvement in health. Variation in health was associated with variation in tinnitus, not variation in speech reception.

Conclusions

None of the four GPMs was sensitive to the improvements in both speech reception and tinnitus that were associated with cochlear implantation. To capture fully the benefits of interventions for auditory disorders, developments of current GPMs would need to be sensitive to both the health-related and non-health-related aspects of auditory dysfunction.
Opmerkingen

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1007/​s11136-018-2070-6) contains supplementary material, which is available to authorised users.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Generic preference-based measures (GPMs) of health-related quality of life (HRQL) play important roles in the allocation of resources in health care because they provide the utility component of cost–utility analyses. Such analyses inform prioritisation of treatments by third-party payers in many jurisdictions and are mandated in England when the National Institute for Health and Care Excellence (NICE) commissions the appraisal of a health technology [1].
There is concern that some GPMs are insensitive to interventions which improve hearing [25]. The issue is relevant because impaired hearing is prevalent. A clinically significant loss is experienced by 10% of all adults and by 30% of those older than 70 years [6, 7]. Sufferers must compete for resources to obtain treatments to alleviate their disability. There would be a failure of equity if treatments were denied not because they were ineffective but because GPMs failed to attribute appropriate value to their benefits.
The development of GPMs begins with researchers identifying dimensions on which good function corresponds to good health. Discrete levels of function are defined on each dimension ranging from poor to good. A subset of the possible combinations of levels is valued by a representative sample of the public. These informants use methods for measuring preferences [8] such that their valuations lie on a scale where 1 corresponds to perfect health, 0 to the state of being dead, and negative values to states considered worse than dead, if relevant. Statistical modelling is used to generate a valuation function which converts any combination of levels into a composite index whose value best aligns with the valuations of the informants. Finally, a questionnaire is compiled to elicit a respondent’s own level of function on each dimension. Then, the responses to the questionnaire and the valuation function are deployed to assign a value to the respondent’s HRQL that reflects public preferences.
We examined four widely used GPMs [911]. The EuroQol Descriptive System [9] includes dimensions relating to Mobility, Self-care, Usual Activities, Pain/Discomfort, and Anxiety/Depression. The version of the system until recently preferred by NICE [12] defines three levels on each dimension (EQ-5D-3L). The Mark-2 version of the Health Utilities Index (HUI2) [10, 13] includes dimensions relating to Sensation, Mobility, Emotion, Cognition, Self-care, and Pain, each with 4–6 levels. In the Mark-3 version (HUI3) [14], Sensation was decomposed into Seeing, Hearing, and (being understood when) Speaking. Self-care was re-worked as Dexterity. The Short-Form-6D (SF-6D) [11] includes dimensions relating to Physical functioning, Role limitations, Social functioning, Pain, Mental health, and Vitality, each with 4–6 levels. The dimensions are a subset of those in the Medical Outcomes Study Short-form Health Survey (SF-36) [15], such that an SF-6D utility can be derived from responses to the SF-36 [11].
Given differences in wording, dimensions, and methods of valuation, it is not surprising that the GPMs differ in their sensitivity to interventions [16], including interventions which improve hearing [e.g. 24]. A systematic review of studies that measured HRQL in participants with impaired hearing using one or more of EQ-5D, HUI3, and SF-6D [5] reached five conclusions: HUI3 was appropriate for estimating HRQL in studies involving impaired hearing; EQ-5D-3L was not responsive to modest changes in hearing; few studies had been designed to compare GPMs; only one study had included SF-6D; additional ‘head-to-head’ comparisons of GPMs were needed to understand why differences in sensitivity arose.
We made such a comparison by investigating the sensitivity of the four GPMs to cochlear implantation—a clinically effective intervention [17] which restores auditory sensations to people with little or no functional hearing [18, 19]. The primary goal of implantation is to improve the ability to understand speech. A secondary goal is to attenuate tinnitus [20, 21]—“the conscious experience of a sound that originates in an involuntary manner in the head of its owner, or may appear to do so” [22]. Up to 80% of candidates for implantation report some degree of tinnitus [23].
The rationale for the study was that the categorical change from dysfunctional hearing to viable hearing that is brought about by implantation would allow scope for GPMs to show improvement if they were sensitive to hearing. The study adds to those in the systematic review [5] of which only two were prospective evaluations of implantation where participants completed questionnaires themselves; both of those studies included only one GPM.
Against that background, we identified reasons why the four GPMs differed in their sensitivity to implantation. We distinguished their response to impaired speech reception from their response to tinnitus, and we considered the implications for the choice of GPM to use in studies of hearing.

Methods

Participants

Participants were adults who met criteria of candidacy for implantation in the United Kingdom (UK): they had developed a severe-to-profound sensorineural hearing loss in both ears after acquiring spoken language; they had at least one patent cochlear nerve; they could identify no more than 50% of the content words in pre-recorded sentences presented in quiet without lipreading when using hearing aids. Their demographic and audiological characteristics are listed in Table 1. They received an implant in one ear in any of 13 hospitals in the UK between June 1997 and May 2000. They were tested one month before implantation and again three and nine months after implantation as part of a larger study [18, 24, 25]. Results are reported for 147 participants (78 F, 69 M) who provided a complete set of outcome measures at the pre-operative and 9 month post-operative stages. Online Resource 1 provides evidence that these participants were representative of adults undergoing implantation in the UK.
Table 1
Biographical and audiological characteristics of participants before implantation
Measure
Minimum
Maximum
Mean
Standard deviation
Age at the time of implantation (years)
18.0
79.3
50.7
14.7
Pre-operative hearing levela of the implanted ear (dB)
88.8
140.0
118.3
10.5
Pre-operative hearing leveal of the other ear (dB)
93.8
140.0
117.5
10.5
Duration of severe-profound deafnessb of the implanted ear (years)
0.0
71.0
14.8
15.7
Duration of severe-profound deafnessb of the other ear (years)
0.0
71.0
14.9
15.4
Pre-operative speech-reception score (% correct)c
0.0
50.0
3.8
9.3
aElevation of detection thresholds for pure tones averaged across the acoustic frequencies of 500, 1000, 2000, and 4000 Hz relative to normal hearing
bSelf-reported by participants
cBKB Sentence Test [18, 29]

Outcome measures

Five measures of HRQL and two functional measures of hearing were derived from four questionnaires and a performance test. The questionnaires were presented on touch screens. The performance test was conducted in audiological test rooms. The measures are described below where the name given to each derived variable is italicised, e.g. EQ-5D-3L.

Measures of HRQL

The EQ-5D-3L questionnaire and visual-analogue scale of the EuroQoL Descriptive System were presented. Reported levels of the five dimensions were converted to a composite index (EQ-5D-3L) using the valuation function described by Dolan [26]. The visual-analogue scale yielded a value in the range from zero (worst imaginable health) to 100 (best imaginable health) (EQ-VAS). For the Health Utilities Index Mark 2 and 3, a single questionnaire allowed both indices to be calculated. The words “hearing aid” were replaced with “cochlear implant” in the version of the questionnaire presented post-operatively. Reported levels of the dimensions were converted to weights which were combined to yield composite indices for HUI2 [13] and HUI3 [14] (HUI2, HUI3). For the Short-Form-6D, responses to the UK SF-36 questionnaire [27] were analysed to determine the level of function of each participant on each dimension and then to compute a composite index [28] (SF-6D).

Functional measures of hearing

A measure of speech reception was obtained by presenting recordings of sentences to participants at an intensity typical of conversational speech and counting the percentage of content words reported correctly [18, 29] (Speech). A measure of annoyance due to tinnitus was obtained by presenting 13 questions [30; Online Resource 2] which probed the subjective manifestations of tinnitus and its psychological impact. Participants responded by positioning a pointer on a visual-analogue scale whose ends were labelled appropriately for each question. Responses were averaged and expressed as a number in the range from 0 (no annoyance) to 100 (great annoyance) (Tinnitus).
A good outcome from implantation is characterised by a high value of Speech and a low value of Tinnitus. Thus, to the extent that speech reception and annoyance due to tinnitus are associated with HRQL, Speech and Tinnitus are expected to display complementary patterns of correlation; where Speech correlates positively, Tinnitus should correlate negatively, and vice versa.

Analyses

Analyses were conducted with IBM SPSS Statistics v.24 [31].

Sensitivity of outcome measures to implantation

We tested the sensitivity of each outcome measure to implantation by determining whether the change from the pre-operative to the post-operative value of the measure exceeded zero using a t test. Effect sizes (ES) were assessed with the Standardised Response Mean [32] and, for descriptive convenience, were classified as small (0.2 ≤ ES < 0.5), moderate (0.5 ≤ ES < 0.8), or large (0.8 ≤ ES). The changes in the four composite indices were compared in an analysis of variance. Mauchly’s test of sphericity was significant, so the Greenhouse-Geisser adjustment was made to the degrees of freedom.

Sensitivity of individual dimensions of GPMs to implantation

To establish which dimensions of each GPM were sensitive to implantation, and to determine whether positive changes on some dimensions were offset by negative changes on others, we identified dimensions on which there was a significant change—either positive or negative—between the levels to which participants assigned themselves before and after implantation using a Wilcoxon signed-rank test.

Sensitivity of composite indices to speech reception and tinnitus

A composite index could be sensitive to variation in both speech reception and tinnitus, to one, or to neither. To determine which pattern of sensitivity was shown by each GPM, we calculated Kendall rank correlation coefficients between changes in Speech and Tinnitus and changes in each composite index. We also examined whether values of Speech and Tinnitus before and, separately, after implantation were correlated with the pre- and post-operative values of the composite indices.

Sensitivity of individual dimensions to speech reception and tinnitus

To determine which individual dimensions underpinned correlations between composite indices and Speech and Tinnitus, we calculated Kendall rank correlation coefficients between changes in the levels of each dimension and changes in Speech and Tinnitus. We also tested whether values of Speech and Tinnitus before and after implantation were correlated with the pre- and post-operative levels of individual dimensions.

Results

Sensitivity of outcome measures to implantation

Table 2 reports the sensitivity of the outcome measures to implantation. In terms of effect size, HUI2 displayed a moderate significant change and HUI3 a large significant change. EQ-5D-3L displayed a small significant change. SF-6D and EQ-VAS did not show significant changes. Analysis of variance showed that the four changes differed significantly (F(2.4,345.2) = 45.3, p < 0.001); all pair-wise comparisons were significant (p < 0.001), except the comparison between EQ-5D-3L and SF-6D.
Table 2
Comparison of values of outcome measures before and after implantation
 
Outcome measure
EQ-5D-3L
HUI2
HUI3
SF-6D
EQ-VAS
Speech
Tinnitus
Mean pre-operative value
0.788
0.640
0.433
0.763
76.66
3.81
23.94
Mean post-operative value
0.827
0.775
0.629
0.775
77.93
56.08
16.81
Mean change in valuea
0.040
0.135
0.197
0.012
1.26
52.27
− 7.13
Student’s t146b
2.30*
8.16***
12.10***
1.20
1.00
18.36***
− 4.05***
Adjusted SRMc
0.20
0.71
1.06
0.12
0.09
1.18
− 0.35
aCalculated as the post-operative value minus the pre-operative value. Improvements are shown by a negative change in Tinnitus (i.e. a reduction in annoyance) and by a positive change in other outcome measures
b*p < 0.05, ***p < 0.001
cAdjusted standardised response mean [32]
The first functional measure of hearing, Speech, increased from 3.8% correct to 56.1% correct with a large effect size. The second functional measure, Tinnitus, declined from 23.9 to 16.8 with a small effect size. Thus, implantation was associated with a large primary effect of improved speech reception and a small secondary effect of reduced annoyance due to tinnitus. Online Resource 3 provides additional support for the interpretation of speech reception as the primary outcome and annoyance due to tinnitus as the secondary outcome.

Sensitivity of individual dimensions of GPMs to cochlear implantation

Table 3 summarises the sensitivity of the individual dimensions of the GPMs to implantation. For each dimension, the table includes the number of participants who placed themselves at each level before and after implantation, together with the results of a comparison of the 147 pairs of levels. As an example, consider the entry for the Anxiety/Depression dimension of EQ-5D-3L which is at top-right in the table. Before implantation, 83 participants placed themselves at the best level of this dimension, 52 at the middle level, and 12 at the worst level, summarised as (83,52,12). After implantation, the pattern had improved significantly to (113,30,4) (Wilcoxon z = 4.812, p < 0.001).
Table 3
Comparison of numbers of participants at each level of each dimension of GPMs before and after implantation
 
EQ-5D-3L dimensions
Mobility
Self-care
Usual activities
Pain/discomfort
Anxiety/depression
N Prea
(110,37,0)
(140,7,0)
(113,28,6)
(99,42,6)
(83,52,12)
N Postb
(108,39,0)
(139,8,0)
(118,27,2)
(89,52,6)
(113,30,4)
Z c,d
− 0.47
− 0.33
+ 1.50
− 1.54
+ 4.81***
 
HUI2 dimensions
Sensation
Mobility
Emotion
Cognition
Self-care
Pain
N Pre
(0,9,65,73)
(125,8,13,1,0)
(95,42,8,2,0)
(103,42,2,0)
(146,1,0,0)
(116,10,9,4,8)
N Post
(0,80,62,5)
(127,6,12,2,0)
(105,37,4,1,0)
(110,34,3,0)
(143,2,0,2)
(93,30,7,0,17)
Z
+ 8.92***
0.000
+ 1.79
+ 0.93
− 1.52
− 2.85**
 
HUI3 dimensions
Vision
Hearing
Speaking
Ambulation
Dexterity
Emotion
Cognition
Pain
N Pre
(48,96,1,1,1,0)
(3,1,11,4,56,72)
(106,21,13,5,2)
(125,8,13,0,1,0)
(145,0,0,2,0,0)
(97,37,7,5,1)
(103,12,16,13,3,0)
(85,27,24,8,3)
N Post
(41,104,0,1,1,0)
(0,2,107,0,33,5)
(114,22,11,0,0)
(127,6,12,1,0,1)
(147,0,0,0,0,0)
(94,41,12,0,0)
(110,7,14,12,4,0)
(72,37,27,10,1)
Z
− 1.26
+ 9.22***
+ 2.08*
+ 0.17
+ 1.41
+ 0.30
+ 0.64
− 1.28
 
SF-6D dimensions
Physical
Role limitations
Social
Pain
Mental health
Vitality
N Pre
(56,46,19,7,15,4)
(95,19,16,17)
(96,16,22,9,4)
(73,22,29,9,11,3)
(27,46,45,26,3)
(13,75,40,13,6)
N Post
(51,43,29,7,13,4)
(96,10,14,27)
(93,21,24,6,3)
(60,30,21,22,12,2)
(51,42,40,12,2)
(17,70,45,11,4)
Z
− 0.80
− 1.11
+ 0.24
− 2.13*
+ 4.53***
+ 0.86
aN Pre Number of participants at each level of a dimension before implantation. Left-hand number in parentheses is the number at the most advantageous level of the dimension; right-hand number is the number at the least advantageous level
bN Post Number of participants at each level of a dimension after implantation
cZ statistic from Wilcoxon signed-rank comparison of pre- and post-operative levels. A negative value indicates that the mean level became less advantageous. A positive value indicates that the mean level became more advantageous
d*p < 0.05, **p < 0.01, ***p < 0.001
Implantation was associated with three types of change: improvements in Sensation (HUI2), Hearing (HUI3), and Speaking (HUI3); improvements in Anxiety/Depression (EQ-5D-3L) and Mental Health (SF-6D); and a worsening of Pain (HUI2, SF-6D). Thus, each GPM included at least one dimension that displayed a significant improvement, while HUI2 and SF-6D also included dimensions that worsened significantly.

Sensitivity of measures of HRQL to speech reception and tinnitus

The upper panel of Table 4 lists Kendall rank-order correlation coefficients between change in Speech and Tinnitus and change in each measure of HRQL. Change in Speech was correlated with change in HUI2 and HUI3, but not with change in EQ-5D-3L or EQ-VAS. Change in Tinnitus showed the opposite pattern; it was correlated with change in EQ-5D-3L and EQ-VAS, but not with change in HUI2 or HUI3. Change in neither functional measure was correlated with change in SF-6D. Thus, none of the composite indices was sensitive to the improvements in both speech reception and tinnitus associated with implantation. Online Resource 4 includes multiple regression analyses which corroborate these patterns of correlation.
Table 4
Kendall rank-order coefficients of correlation among functional measures of hearing and measures of HRQL
 
Tinnitus
EQ-5D-3L
HUI2
HUI3
SF-6D
EQ-VAS
Change in valuesa
 Speech
− 0.056
0.118
0.185**
0.191**
0.051
− 0.004
 Tinnitus
 
− 0.182*
− 0.112
− 0.069
− 0.054
− 0.179**
Pre-operative valuesb
 Speech
− 0.053
0.022
0.178 *
0.137
0.135
0.053
 Tinnitus
 
− 0.223**
− 0.230**
− 0.242**
− 0.247**
− 0.225**
Post-operative valuesc
 Speech
0.002
0.128
0.195**
0.189**
0.136
0.044
 Tinnitus
 
− 0.242**
− 0.201**
− 0.206**
− 0.251**
− 0.236**
Low values of Tinnitus, but high values of Speech and of measures of HRQL, were advantageous pre- and post-operatively. A negative change in Tinnitus, but a positive change in Speech and in measures of HRQL, represented improvements. Thus, correlations between Tinnitus and measures of HRQL were negative, while correlations between Speech and measures of HRQL were positive
Significance assessed against Bonferroni-adjusted alpha levels of 0.01 per test (0.05/5) (*) and 0.002 per test (0.01/5) (**)
aCorrelations among changes in measures; change was calculated as the post-operative value minus the pre-operative value
bCorrelations among pre-operative values of measures
cCorrelations among post-operative values of measures
The middle and lower panels of Table 4 list coefficients of correlation between the functional measures of hearing and the measures of HRQL before and after implantation. Of the five measures of HRQL, only HUI2 was correlated with Speech before implantation, and only HUI2 and HUI3 were correlated with Speech after implantation. In contrast, each measure of HRQL was correlated with Tinnitus, both before and after implantation.

Sensitivity of individual dimensions to speech reception and tinnitus

Table 5 lists coefficients of correlation between the levels of individual dimensions and measures of Speech and Tinnitus. The results corroborate the implication of Table 4 that the GPMs were more attuned to variation among participants in Tinnitus than in Speech. The four GPMS together contain 25 dimensions. Variation in Speech was correlated significantly with the levels of only four of them before or after implantation, while variation in Tinnitus was correlated with 15.
Table 5
Kendall rank-order coefficients of correlationa between functional measures of hearing and levels of individual dimensions of GPMs
GPM
Dimension
Pre-operative
Post-operative
Change
τ b
Sig.e
τ c
Sig.e
τ d
Sig.e
(a) Correlations with Speech
 EQ-5D-3L
Mobility
− 0.090
 
− 0.041
 
0.020
 
 
Self-care
0.030
 
− 0.097
 
− 0.015
 
 
Usual activities
0.036
 
− 0.019
 
− 0.060
 
 
Pain/Discomfort
− 0.021
 
− 0.064
 
− 0.003
 
 
Anxiety/Depression
0.020
 
− 0.212
*
− 0.174
*
 HUI2
Sensation
− 0.359
**
− 0.263
**
− 0.230
**
 
Mobility
− 0.112
 
− 0.083
 
− 0.096
 
 
Emotion
− 0.008
 
− 0.068
 
− 0.082
 
 
Cognition
0.094
 
− 0.154
 
− 0.054
 
 
Self-care
− 0.047
 
− 0.027
 
− 0.057
 
 
Pain
0.052
 
− 0.075
 
− 0.040
 
 HUI3
Vision
0.055
 
− 0.071
 
− 0.058
 
 
Hearing
− 0.325
**
− 0.193
*
− 0.225
**
 
Speaking
0.074
 
− 0.165
 
0.023
 
 
Ambulation
− 0.112
 
− 0.083
 
− 0.096
 
 
Dexterity
− 0.066
 
f
 
− 0.071
 
 
Emotion
− 0.022
 
− 0.061
 
− 0.071
 
 
Cognition
0.092
 
− 0.159
 
− 0.085
 
 
Pain
− 0.060
 
− 0.102
 
0.006
 
 SF-6D
Physical functioning
− 0.098
 
− 0.112
 
− 0.097
 
 
Role limitations
− 0.092
 
− 0.078
 
− 0.019
 
 
Social functioning
− 0.131
 
− 0.115
 
− 0.134
 
 
Pain
− 0.051
 
− 0.090
 
− 0.047
 
 
Mental Health
− 0.163
 
− 0.201
**
− 0.055
 
 
Vitality
− 0.035
 
− 0.025
 
− 0.031
 
(b) Correlations with Tinnitus
 EQ-5D-3L
Mobility
0.216
*
0.227
**
0.062
 
 
Self-care
0.072
 
− 0.017
 
− 0.031
 
 
Usual activities
0.204
*
0.250
**
0.150
 
 
Pain/discomfort
0.180
*
0.208
*
0.134
 
 
Anxiety/depression
0.136
 
0.194
*
0.185
*
 HUI2
Sensation
0.207
*
0.054
 
0.042
 
 
Mobility
0.173
 
0.123
 
− 0.103
 
 
Emotion
0.076
 
0.125
 
0.053
 
 
Cognition
0.174
 
0.171
 
0.120
 
 
Self-care
0.007
 
− 0.033
 
− 0.126
 
 
Pain
0.137
 
0.201
*
− 0.004
 
 HUI3
Vision
− 0.095
 
0.073
 
− 0.029
 
 
Hearing
0.193
*
0.083
 
0.043
 
 
Speaking
0.041
 
0.003
 
− 0.032
 
 
Ambulation
0.173
 
0.123
 
− 0.103
 
 
Dexterity
0.068
 
f
 
− 0.075
 
 
Emotion
0.199
*
0.197
*
0.034
 
 
Cognition
0.181
*
0.167
 
0.124
 
 
Pain
0.162
 
0.189
*
0.050
 
 SF-6D
Physical functioning
0.164
 
0.149
 
− 0.012
 
 
Role limitations
0.172
*
0.255
**
0.133
 
 
Social functioning
0.245
**
0.178
*
0.142
 
 
Bodily pain
0.167
 
0.212
**
0.053
 
 
Mental health
0.132
 
0.195
*
0.102
 
 
Vitality
0.192
*
0.270
**
0.116
 
aLevels of dimensions were quantified with sequential integers. The value 1 was assigned to the most advantageous level. Thus, low values of level were advantageous pre- and post-operatively, and a reduction in level represented an improvement. Low values of Tinnitus, but high values of Speech and of measures of HRQL, were advantageous pre- and post-operatively. A negative change in Tinnitus, but a positive change in Speech and in measures of HRQL, represented improvements. Therefore, correlations between Tinnitus and level were generally positive, while correlations between Speech and level were generally negative
bKendall rank-order coefficients of correlation between pre-operative values of measures
cKendall rank-order coefficients of correlation between post-operative values of measures
dKendall rank-order coefficients of correlation between changes in measures calculated as the post-operative value minus the pre-operative value
eSignificance assessed against Bonferroni-adjusted alpha levels of 0.05/n (*) and 0.01/n (**), where n is the number of dimensions in the GPM (5 for EQ-5D-3L, 6 for HUI2, 8 for HUI3, and 6 for SF-6D).
fCould not be calculated because all participants placed themselves at the most advantageous level of the Dexterity dimension after implantation

Discussion

The data reported here were gathered in the late 1990s. Improvements in cochlear implants and changes in candidature might have rendered the results irrelevant to today’s outcomes. Two considerations counter those concerns. First, criteria of candidacy for unilateral implantation of adults in England [17] remain the same as the entry criteria for the study, although they are currently under review [33]. Second, accuracy of speech reception following implantation has plateaued since the mid-1990s [34]. Thus, participants in the study, and patients receiving implants in England today, are likely to come from the same population and to demonstrate the same patterns of association among outcome measures.
With those caveats, the study provides evidence at three levels of detail to inform the choice of GPM to use in assessments of interventions for hearing disorders. First, at the level of composite indices, the results corroborate previous demonstrations [25] that GPMs differ in their sensitivity to treatments which improve hearing (Table 2): HUI2 and HUI3 showed moderate or large responses to implantation; EQ-5D-3L showed a small response; and SF-6D showed no response. In consequence, economic analyses informed by HUI2 or HUI3 suggest that implantation is a cost-effective intervention, while analyses informed by EQ-5D-3L or SF-6D suggest that it is not (Online Resource 5). That result might argue that only HUI3 need be used in studies of hearing.
However, limitations in all of the GPMs emerge at the second level of detail where the changes associated with implantation on individual dimensions are considered (Table 3). Significant changes occurred on three groups of dimensions: positive changes resulting from improved auditory sensitivity; positive changes resulting from improved psychological well-being; and negative changes presumably resulting from pain caused by the surgical wound and from irritation induced by wearing the external parts of the implant system against the scalp. Limitations of the GPMs are shown by the fact that no GPM displayed all three types of change.
It is not surprising that the composite indices of HUI2 and HUI3 were sensitive to the improvement in speech reception, given that the questions which map respondents onto the levels of the Sensation (HUI2) and Hearing (HUI3) dimensions ask about the ability to “hear what is said” in conversation. More surprising may be that neither Usual Activities (EQ-5D-3L) nor Role Limitations or Social Functioning (SF-6D) were similarly sensitive. However, participants had been severely profoundly hearing impaired for nearly 15 years on average (Table 1), so their “usual” activities would have adapted to constraints imposed by their deafness. Also, the questions that map respondents onto levels of the Role Limitations and Social Functioning dimensions emphasise limitations arising from health. The loss of hearing sensitivity that underpins impaired speech reception is not usually the consequence of disease [35] nor is it generally perceived to be a manifestation of ill-health [36].
In contrast, evidence from the third level of detail—individual differences in outcome measures before and after implantation—shows that annoyance due to tinnitus was perceived to be strongly related to perceptions of health (Table 4b). It was associated with poorer levels of function on dimensions related to physical activity (Mobility and Usual Activities in EQ-5D-3L, Role Limitations and Social Function in SF-6D), pain (Pain/Discomfort in EQ-5D-3L, Pain in HUI2, HUI3, SF-6D), and mental health (Anxiety/Depression in EQ-5D-3L, Emotion in HUI3, Mental Health in SF-6D). This pattern (see also [37]) can be rationalised by the ideas that the negative influence of tinnitus on the capacity to concentrate reduces productive activity [38], that tinnitus is discomforting and akin to pain [39, 40], and that tinnitus either elevates anxiety [41] or anxiety exacerbates the experience of tinnitus [42].
The conclusion that the GPMs are more attuned to tinnitus than impaired speech reception is reinforced by the finding that variation among participants in the change in self-reported health, EQ-VAS, was correlated with the change in Tinnitus, not the change in Speech (Table 4). The conclusion is supported by supplementary analyses in Online Resource 6 and is also compatible with analyses reported by Konerding et al. [16] who examined patterns of association among dimensions of EQ-5D-3L, HUI2, and SF-6D. Correlated patterns across the three GPMs were found among dimensions related to mental health and, separately, physical functioning, and physical pain. The Sensation dimension of HUI2, however, was not related to other dimensions, suggesting that sensory deficits are independent of other aspects of health. That conclusion anticipates the demonstration in the present paper and elsewhere [25] that sensitivity to interventions which improve the ability to detect sounds is shown only by those GPMs that explicitly measure the benefits of improved auditory sensitivity.
Which GPM should be used in studies of hearing? Consider first that Tinnitus was associated with aspects of health which are represented by dimensions in each GPM. All of the GPMs, therefore, have the potential to be sensitive to changes in health produced by interventions which reduce annoyance due to tinnitus. Although in the present study only EQ-5D-3L was sensitive to the small improvement in Tinnitus (Table 4), in a clinical trial reported by Maes et al. [43], both EQ-5D-3L and HUI3 distinguished patients whose tinnitus improved from patients whose tinnitus did not improve, with HUI3 showing slightly greater sensitivity. Thus, in jurisdictions where policy makers prefer HUI3, it should be used in studies of hearing, insofar as it has been shown to be sensitive to improvements in both tinnitus and auditory sensitivity.
In jurisdictions where policy makers prefer EQ-5D, it should be used to evaluate interventions intended to improve tinnitus, while HUI3 should be used to evaluate interventions intended to improve hearing sensitivity. That distinction aligns with the guidance given by NICE that alternatives to EQ-5D should be used to evaluate conditions for which EQ-5D lacks critical dimensions of health [1]. Nonetheless, it is unsatisfactory to advocate the use of different GPMs to assess treatments for two aspects of dysfunctional hearing which can co-occur and which can both respond to the same treatment. The dilemma reinforces the aim of a consortium of researchers in the UK [44] to develop a successor to the EuroQol Descriptive System which preserves sensitivity to the conventional dimensions of health while adding sensitivity to sensory disorders [45, 46] among other changes.

Acknowledgements

This study was supported by the intra-mural programme of the Medical Research Council (UK) and Defeating Deafness—The Hearing Research Trust. At the time when the data were gathered, AQS and GRB were employed by the Medical Research Council. The UK Cochlear Implant Study Group involved clinicians in adult cochlear implant programmes in 14 NHS hospitals together with researchers at the MRC Institute of Hearing Research and the University of York. The lead surgeons and clinical coordinators of the programmes were Mr J. Toner FRCS and Mrs C. McAnallen (City Hospital, Belfast), Mr D. Proops FRCS and Mr H. Cooper (Queen Elizabeth Hospital, Birmingham), Mr C. Raine FRCS and Mr S. Khan (Royal Infirmary, Bradford), Mr R. Evans FRCS and Mr. J. Joseph (Princess of Wales Hospital, Bridgend), Mr R. Gray FRCS and Mrs I. Court (Addenbrooke’s Hospital, Cambridge), Mr A. Kerr FRCS and Dr. R. Barr-Hamilton (Royal Infirmary, Edinburgh), Mr J. Osborne FRCS and Ms M. Doran (Glan Clwyd Hospital, Bodelwyddan), Mr. R. Singh FRCS and Dr. A. Allen (Crosshouse Hospital, Kilmarnock), Mr J. Graham FRCS and Ms. W. Aleksy (Royal National Throat Nose and Ear Hospital, London), Mr A. Fitzgerald-O’Connor FRCS and Dr. T. Nunn (St. Thomas’ Hospital, London), Professor R. Ramsden FRCS and Mr. M. O’Driscoll (Royal Infirmary, Manchester), Mr G.M. O’Donoghue FRCS, Mr. K.P. Gibbin FRCS, and Mr. G. Armstrong-Bednall (University Hospital, Nottingham), Mr D. Chapman FRCS and Ms D. Gratton (Royal Hallamshire Hospital, Sheffield), and Mr P. Ashcroft FRCS, Mr M. Pringle FRCS, and Mrs J. Eyles (Institute of Sound and Vibration Research, Southampton). We thank Dr Pádraig Kitterick, Dr David Marshall, Mr John Foster, and Professor Karen Bloor for advice. We thank three anonymous reviewers whose critiques materially improved the paper.

Compliance with ethical standards

Conflict of interest

During the 1990s and 2000s, AQS received remuneration of the costs of attending scientific conferences from manufacturers of cochlear implants which had invited him to present the results of research. While attending conferences, AQS received hospitality from manufacturers of cochlear implants. Between 2008 and 2010, AQS received a research grant from a manufacturer of cochlear implants to develop an apparatus to measure the listening skills of users of cochlear implants. Between 2006 and 2010, AQS was chief scientific advisor to the charity, Deafness Research UK—The hearing Research Trust, from which he had previously received a research grant that contributed to the costs of the study reported in this paper. AQS is a trustee of the charity, Action on Hearing Loss, which campaigns on behalf of people who are deaf, have hearing loss, or suffer from tinnitus. Garry Barton (GRB) declares that he has no conflict of interest.

Ethical approval

The research reported in this paper was approved by a multi-centre research ethics committee of the UK National Health Service. All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed consent was obtained from all individual participants included in the study.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Onze productaanbevelingen

BSL Podotherapeut Totaal

Binnen de bundel kunt u gebruik maken van boeken, tijdschriften, e-learnings, web-tv's en uitlegvideo's. BSL Podotherapeut Totaal is overal toegankelijk; via uw PC, tablet of smartphone.

Bijlagen

Electronic supplementary material

Below is the link to the electronic supplementary material.
Literatuur
2.
go back to reference Barton, G. R., Bankart, J., Davis, A. C., & Summerfield, A. Q. (2004). Comparing utility scores before and after hearing-aid provision. Applied Health Economics and Health Policy, 3, 103–105.CrossRefPubMed Barton, G. R., Bankart, J., Davis, A. C., & Summerfield, A. Q. (2004). Comparing utility scores before and after hearing-aid provision. Applied Health Economics and Health Policy, 3, 103–105.CrossRefPubMed
3.
go back to reference Barton, G. R., Bankart, J., & Davis, A. C. (2005). A comparison of the quality of life of hearing-impaired people as estimated by three different utility measures. International Journal of Audiology, 44, 157–163.CrossRefPubMed Barton, G. R., Bankart, J., & Davis, A. C. (2005). A comparison of the quality of life of hearing-impaired people as estimated by three different utility measures. International Journal of Audiology, 44, 157–163.CrossRefPubMed
4.
go back to reference Grutters, J. P. C., Joore, M. A., van der Horst, F., Verschuure, H., Dreschler, W. A., & Anteunis, L. J. C. (2007). Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints. Quality of Life Research, 16, 1439–1449.CrossRefPubMedPubMedCentral Grutters, J. P. C., Joore, M. A., van der Horst, F., Verschuure, H., Dreschler, W. A., & Anteunis, L. J. C. (2007). Choosing between measures: comparison of EQ-5D, HUI2 and HUI3 in persons with hearing complaints. Quality of Life Research, 16, 1439–1449.CrossRefPubMedPubMedCentral
5.
go back to reference Yang, Y., Longworth, L., & Brazier, J. (2013). An assessment of the validity and responsiveness of generic measures of health-related quality of life in hearing impairment. Quality of Life Research, 22, 2813–2828.CrossRefPubMedPubMedCentral Yang, Y., Longworth, L., & Brazier, J. (2013). An assessment of the validity and responsiveness of generic measures of health-related quality of life in hearing impairment. Quality of Life Research, 22, 2813–2828.CrossRefPubMedPubMedCentral
6.
go back to reference Davis, A. C. (1995). Hearing in adults. London: Whurr Publishers Ltd. Davis, A. C. (1995). Hearing in adults. London: Whurr Publishers Ltd.
7.
8.
go back to reference Drummond, M. F., O’Brien, B., Stoddart, G. L., & Torrance, G. W. (1997). Methods for the economic evaluation of health care programmes. Oxford: Oxford University Press. Drummond, M. F., O’Brien, B., Stoddart, G. L., & Torrance, G. W. (1997). Methods for the economic evaluation of health care programmes. Oxford: Oxford University Press.
9.
go back to reference Brooks, R., Rabin, R., & de Charro, F. (2003). The measurement and evaluation of health status using EQ-5D: A European perspective. Dordrecht: Kluwer Academic Publishers.CrossRef Brooks, R., Rabin, R., & de Charro, F. (2003). The measurement and evaluation of health status using EQ-5D: A European perspective. Dordrecht: Kluwer Academic Publishers.CrossRef
10.
go back to reference Horsman, J., Furlong, W., Feeny, D., & Torrance, G. (2003). The Health Utilities Index (HUI): Concepts, measurement properties and applications. Health Quality of Life Outcomes, 16, 1:54. Horsman, J., Furlong, W., Feeny, D., & Torrance, G. (2003). The Health Utilities Index (HUI): Concepts, measurement properties and applications. Health Quality of Life Outcomes, 16, 1:54.
11.
go back to reference Brazier, J., Roberts, J., & Deverill, M. (2002). The estimation of a preference-based measure of health from the SF-36. Journal of Health Economics, 21, 271–292.CrossRefPubMed Brazier, J., Roberts, J., & Deverill, M. (2002). The estimation of a preference-based measure of health from the SF-36. Journal of Health Economics, 21, 271–292.CrossRefPubMed
13.
go back to reference Torrance, G., Feeny, D., Furlong, W., Barr, R., Zhang, Y., & Wang, Q. (1996). Multiattribute utility function for a comprehensive health status classification system: Health Utilities Index Mark 2. Medical Care, 7, 702–722.CrossRef Torrance, G., Feeny, D., Furlong, W., Barr, R., Zhang, Y., & Wang, Q. (1996). Multiattribute utility function for a comprehensive health status classification system: Health Utilities Index Mark 2. Medical Care, 7, 702–722.CrossRef
14.
go back to reference Feeny, D., Furlong, W., Torrance, G. W., Goldsmith, C. H., Zhu, Z., DePauw, S., Denton, M., & Boyle, M. (2002). Multiattribute and single-attribute utility functions for the Health Utilities Index Mark 3 system. Medical Care, 40, 113–128.CrossRefPubMed Feeny, D., Furlong, W., Torrance, G. W., Goldsmith, C. H., Zhu, Z., DePauw, S., Denton, M., & Boyle, M. (2002). Multiattribute and single-attribute utility functions for the Health Utilities Index Mark 3 system. Medical Care, 40, 113–128.CrossRefPubMed
15.
go back to reference Ware, J. E., Snow, K. K., Kosinski, M., & Gandek, B. (1993). SF-36 Health Survey: Manual and Interpretation Guide. Boston: The Health Institute, New England Medical Center. Ware, J. E., Snow, K. K., Kosinski, M., & Gandek, B. (1993). SF-36 Health Survey: Manual and Interpretation Guide. Boston: The Health Institute, New England Medical Center.
16.
go back to reference Konerding, U., Moock, J., & Kohlmann, T. (2009). The classification systems of the EQ-5D, the HUI II and the SF-6D: What do they have in common? Quality of Life Research, 18, 1249–1261.CrossRefPubMed Konerding, U., Moock, J., & Kohlmann, T. (2009). The classification systems of the EQ-5D, the HUI II and the SF-6D: What do they have in common? Quality of Life Research, 18, 1249–1261.CrossRefPubMed
18.
go back to reference UK Cochlear Implant Study Group. (2004). Criteria of candidacy for unilateral cochlear implantation in postlingually deafened adults I: Theory and measures of effectiveness. Ear and Hearing, 25, 310–335.CrossRef UK Cochlear Implant Study Group. (2004). Criteria of candidacy for unilateral cochlear implantation in postlingually deafened adults I: Theory and measures of effectiveness. Ear and Hearing, 25, 310–335.CrossRef
19.
go back to reference Bond, M., Mealing, S., Anderson, R., Elston, J., Weiner, G., Taylor, R. S., Hoyle, M., Liu, Z., Price, A., & Stein, K. (2009). The effectiveness and cost-effectiveness of cochlear implants for severe to profound deafness in children and adults: A systematic review and economic model. Health Technology Assessment, 13, 1–330.PubMed Bond, M., Mealing, S., Anderson, R., Elston, J., Weiner, G., Taylor, R. S., Hoyle, M., Liu, Z., Price, A., & Stein, K. (2009). The effectiveness and cost-effectiveness of cochlear implants for severe to profound deafness in children and adults: A systematic review and economic model. Health Technology Assessment, 13, 1–330.PubMed
20.
go back to reference Coles, R. R. A. (1997). Tinnitus. In A. G. Kerr (Ed.), Scott-brown otolaryngology. London: Butterworth-Heinemann. Coles, R. R. A. (1997). Tinnitus. In A. G. Kerr (Ed.), Scott-brown otolaryngology. London: Butterworth-Heinemann.
21.
go back to reference Dauman, R. (2000). Electrical stimulation for tinnitus suppression. In R. Tyler (Ed.), Tinnitus handbook (pp. 377–398). San Diego: Singular. Dauman, R. (2000). Electrical stimulation for tinnitus suppression. In R. Tyler (Ed.), Tinnitus handbook (pp. 377–398). San Diego: Singular.
22.
go back to reference McFadden, D. (1982). Tinnitus: Facts, theories, and treatments. Report of Working Group 89, Committee on Hearing Bioacoustics and Biomechanics. Washington, DC. McFadden, D. (1982). Tinnitus: Facts, theories, and treatments. Report of Working Group 89, Committee on Hearing Bioacoustics and Biomechanics. Washington, DC.
23.
go back to reference Tyler, R. S., & Kelsay, D. (1990). Advantages and disadvantages reported by some of the better cochlear-implant users. American Journal of Otology 11. Tyler, R. S., & Kelsay, D. (1990). Advantages and disadvantages reported by some of the better cochlear-implant users. American Journal of Otology 11.
24.
go back to reference UK Cochlear Implant Study Group. (2004). Criteria of candidacy for unilateral cochlear implantation in postlingually deafened adults II: Cost-effectiveness analysis. Ear and Hearing, 25, 336–360.CrossRef UK Cochlear Implant Study Group. (2004). Criteria of candidacy for unilateral cochlear implantation in postlingually deafened adults II: Cost-effectiveness analysis. Ear and Hearing, 25, 336–360.CrossRef
25.
go back to reference UK Cochlear Implant Study Group. (2004). Criteria of candidacy for unilateral cochlear implantation in postlingually deafened adults III: Prospective evaluation of an actuarial approach to defining a criterion. Ear and Hearing, 25, 360–374. UK Cochlear Implant Study Group. (2004). Criteria of candidacy for unilateral cochlear implantation in postlingually deafened adults III: Prospective evaluation of an actuarial approach to defining a criterion. Ear and Hearing, 25, 360–374.
26.
27.
go back to reference Jenkinson, C., Layte, R., Wright, L., & Coulter, A. (1996). The UK SF-36: An analysis and interpretation manual. Oxford: Health Services Research Unit, Department of Public Health and Primary Care, University of Oxford. Jenkinson, C., Layte, R., Wright, L., & Coulter, A. (1996). The UK SF-36: An analysis and interpretation manual. Oxford: Health Services Research Unit, Department of Public Health and Primary Care, University of Oxford.
29.
go back to reference Bench, J., Kowal, A., & Bamford, J. (1979). The BKB (Bamford-Kowal-Bench) sentence lists for partially-hearing children. British Journal of Audiology, 13, 108–112.CrossRefPubMed Bench, J., Kowal, A., & Bamford, J. (1979). The BKB (Bamford-Kowal-Bench) sentence lists for partially-hearing children. British Journal of Audiology, 13, 108–112.CrossRefPubMed
30.
go back to reference Sissons, C. (1996). Tinnitus questionnaire items for measures of severity, maskability, and intrusion/annoyance. Dissertation presented to the Department of Public Health and Epidemiology, University of Nottingham. Sissons, C. (1996). Tinnitus questionnaire items for measures of severity, maskability, and intrusion/annoyance. Dissertation presented to the Department of Public Health and Epidemiology, University of Nottingham.
31.
go back to reference IBM Corporation. (2016). IBM SPSS Statistics for Windows, Version 22.0. Armonk. New York: IBM Corp. IBM Corporation. (2016). IBM SPSS Statistics for Windows, Version 22.0. Armonk. New York: IBM Corp.
32.
go back to reference Norman, G. R., Wyrwich, K. W., & Patrick, D. L. (2007). The mathematical relationship among different forms of responsiveness coefficients. Quality of Life Research, 16, 815–822.CrossRefPubMed Norman, G. R., Wyrwich, K. W., & Patrick, D. L. (2007). The mathematical relationship among different forms of responsiveness coefficients. Quality of Life Research, 16, 815–822.CrossRefPubMed
34.
go back to reference Zeng, F. G. (2017). Challenges in improving cochlear implant performance and accessibility. IEEE Transactions in Biomedical Engineering, 64, 1662–1664.CrossRef Zeng, F. G. (2017). Challenges in improving cochlear implant performance and accessibility. IEEE Transactions in Biomedical Engineering, 64, 1662–1664.CrossRef
35.
go back to reference Cruickshanks, K. J., Tweed, T. S., Wiley, T. L., Klein, B. E., Klein, R., Chappell, R., Nondahl, D. M., & Dalton, D. S. (2003). The 5-year incidence and progression of hearing loss: The epidemiology of hearing loss study. Archives of Otolaryngology Head and Neck Surgery, 129, 1041–1046.CrossRefPubMed Cruickshanks, K. J., Tweed, T. S., Wiley, T. L., Klein, B. E., Klein, R., Chappell, R., Nondahl, D. M., & Dalton, D. S. (2003). The 5-year incidence and progression of hearing loss: The epidemiology of hearing loss study. Archives of Otolaryngology Head and Neck Surgery, 129, 1041–1046.CrossRefPubMed
36.
go back to reference Sach, T. H., & Barton, G. R. (2007). Interpreting parental proxy reports of (health-related) quality of life for children with unilateral cochlear implants. International Journal of Pediatric Otorhinolaryngology, 71, 435–445.CrossRefPubMed Sach, T. H., & Barton, G. R. (2007). Interpreting parental proxy reports of (health-related) quality of life for children with unilateral cochlear implants. International Journal of Pediatric Otorhinolaryngology, 71, 435–445.CrossRefPubMed
37.
go back to reference Nondahl, D. M., Cruickshanks, K. J., Dalton, D. S., Klein, B. E., Klein, R., Schubert, C. R., Tweed, T. S., & Wiley, T. L. (2007). The impact of tinnitus on quality of life in older adults. Journal of the American Academy of Audiology, 18, 257–266.CrossRefPubMed Nondahl, D. M., Cruickshanks, K. J., Dalton, D. S., Klein, B. E., Klein, R., Schubert, C. R., Tweed, T. S., & Wiley, T. L. (2007). The impact of tinnitus on quality of life in older adults. Journal of the American Academy of Audiology, 18, 257–266.CrossRefPubMed
38.
39.
go back to reference Folmer, R. L., Griest, S. E., & Martin, W. H. (2001). Chronic tinnitus as phantom auditory pain. Otolaryngology Head and Neck Surgery, 124, 394–400.CrossRefPubMed Folmer, R. L., Griest, S. E., & Martin, W. H. (2001). Chronic tinnitus as phantom auditory pain. Otolaryngology Head and Neck Surgery, 124, 394–400.CrossRefPubMed
40.
go back to reference Erlandsson, S. I., & Hallberg, L. R. (2000). Prediction of quality of life in patients with tinnitus. British Journal of Audiology, 34, 11–20.CrossRefPubMed Erlandsson, S. I., & Hallberg, L. R. (2000). Prediction of quality of life in patients with tinnitus. British Journal of Audiology, 34, 11–20.CrossRefPubMed
41.
go back to reference Sullivan, M., Katon, W. J., Russo, J., Dobie, R., & Sakai, C. (1992). Somatization, co-morbidity, and the quality of life: Measuring the effect of depression upon chronic medical illness. Psychiatric Medicine, 10, 61–76.PubMed Sullivan, M., Katon, W. J., Russo, J., Dobie, R., & Sakai, C. (1992). Somatization, co-morbidity, and the quality of life: Measuring the effect of depression upon chronic medical illness. Psychiatric Medicine, 10, 61–76.PubMed
42.
go back to reference McCormack, A., Edmondson-Jones, M., Fortnum, H., Dawes, P. D., Middleton, H., Munro, K. J., & Moore, D. R. (2015). Investigating the association between tinnitus severity and symptoms of depression and anxiety, while controlling for neuroticism, in a large middle-aged UK population. International Journal of Audiology, 54, 599–604.CrossRefPubMedPubMedCentral McCormack, A., Edmondson-Jones, M., Fortnum, H., Dawes, P. D., Middleton, H., Munro, K. J., & Moore, D. R. (2015). Investigating the association between tinnitus severity and symptoms of depression and anxiety, while controlling for neuroticism, in a large middle-aged UK population. International Journal of Audiology, 54, 599–604.CrossRefPubMedPubMedCentral
43.
go back to reference Maes, I. H. L., Joore, M. A., Cima, R. F. F., Vlayen, J. W., & Anteunis, J. C. (2011). Assessment of health state in patients with tinnitus: a comparison of the EQ-5D and HUI Mark III. Ear and Hearing, 32, 428–435.CrossRefPubMed Maes, I. H. L., Joore, M. A., Cima, R. F. F., Vlayen, J. W., & Anteunis, J. C. (2011). Assessment of health state in patients with tinnitus: a comparison of the EQ-5D and HUI Mark III. Ear and Hearing, 32, 428–435.CrossRefPubMed
45.
go back to reference Yang, Y., Rowen, D., Brazier, J., Tsuchiya, A., Young, T., & Longworth, L. (2015). An exploratory study to test the impact on three ‘bolt-on’ items to the EQ-5D. Value Health, 18, 52–60.CrossRefPubMedPubMedCentral Yang, Y., Rowen, D., Brazier, J., Tsuchiya, A., Young, T., & Longworth, L. (2015). An exploratory study to test the impact on three ‘bolt-on’ items to the EQ-5D. Value Health, 18, 52–60.CrossRefPubMedPubMedCentral
46.
go back to reference Finch, A. P., Brazier, J. E., & Mukuria, C. (2017). An exploratory study on using principal-component analysis and confirmatory factor analysis to identify bolt-on dimensions: The EQ-5D case study. Value Health, 20, 1362–1375.CrossRefPubMed Finch, A. P., Brazier, J. E., & Mukuria, C. (2017). An exploratory study on using principal-component analysis and confirmatory factor analysis to identify bolt-on dimensions: The EQ-5D case study. Value Health, 20, 1362–1375.CrossRefPubMed
Metagegevens
Titel
Sensitivity of EQ-5D-3L, HUI2, HUI3, and SF-6D to changes in speech reception and tinnitus associated with cochlear implantation
Auteurs
A. Q. Summerfield
G. R. Barton
the UK Cochlear Implant Study Group
Publicatiedatum
27-11-2018
Uitgeverij
Springer International Publishing
Gepubliceerd in
Quality of Life Research / Uitgave 5/2019
Print ISSN: 0962-9343
Elektronisch ISSN: 1573-2649
DOI
https://doi.org/10.1007/s11136-018-2070-6

Andere artikelen Uitgave 5/2019

Quality of Life Research 5/2019 Naar de uitgave