Skip to main content
Log in

Routine breath-hold gradient echo MRI-derived right ventricular mass, volumes and function: accuracy, reproducibility and coherence study

  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

Right ventricular (RV) dysfunction is a predictor of poor outcome in patients with heart disease. Conventional imaging modalities fail to assess RV volumes accurately. We sought to assess the accuracy and reproducibility of routine breath-hold gradient echo magnetic resonance imaging (MRI)-derived RV mass, volumes and function. We assessed (1) The accuracy of in vivo MRI-derived RV mass in comparison to the RV weight in 9 minipigs. (2) Intra- and inter-observer reproducibility of RV mass, end-diastolic (EDV) and end-systolic (ESV) volumes and ejection fraction (EF) in 15 normal volunteers and 10 patients with heart disease. (3) Inter-study reproducibility of the former parameters in 25 coronary artery disease patients. (4) The correlation between right and left ventricular stroke volumes in the total population. Strong statistically significant correlations were found between: (1) MRI-derived RV mass and RV weight (r = 0.98, bias = 2.5 g), (2) Intra-observer measurements of RV mass (r = 0.96, bias = 0.5 g), EDV (r = 0.99, bias = −1.5 ml), ESV (r = 0.98, bias = 0.1 ml) and EF (r = 0.92, bias = −1.4%), (3) Inter-observer measurements of RV mass (r = 0.95, bias = 1.1 g), EDV (r = 0.98, bias = −1.1 ml), ESV (r = 0.98, bias = 1.2 ml) and EF (r = 0.87, bias = −1.9%), (4) Inter-study measurements of RV mass (r = 0.91, bias = −0.1 g), EDV (r = 0.96, bias = 3.8 ml), ESV (r = 0.98, bias = 0.3 ml) and EF (r = 0.90, bias = 0.9%), (5) MRI-derived right and left ventricular stroke volumes (r = 0.87). The assessment of the RV mass, volumes and function by routine breath-hold gradient echo MRI is accurate and highly reproducible. The correlation between left and RV MRI-derived stroke volumes indicates excellent coherence of simultaneous bi-ventricular volume measurements.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Abbreviations

EDV:

end-diastolic volume

ESV:

end-systolic volume

EF:

ejection fraction

LV:

left ventricular

MRI:

magnetic resonance imaging

RV -:

ight ventricular

References

  • HD White RM Norris MA Brown et al. (1987) ArticleTitleEffect of intravenous streptokinase on left ventricular function and early survival after acute myocardial infarction N Engl J Med 317 850–855 Occurrence Handle1:STN:280:DyaL2szhsFaltw%3D%3D Occurrence Handle2888018 Occurrence Handle10.1056/NEJM198710013171402

    Article  CAS  PubMed  Google Scholar 

  • D Levy RJ Garrison DD Savage WB Kannel WP Castelli (1990) ArticleTitlePrognostic implications of echocardiographically determined left ventricular mass in the Framingham Heart Study N Engl J Med 322 IssueID22 1561–1566 Occurrence Handle1:STN:280:DyaK3c3ksFSmug%3D%3D Occurrence Handle2139921 Occurrence Handle10.1056/NEJM199005313222203

    Article  CAS  PubMed  Google Scholar 

  • TR Bowers WW O’Neill C Grines MC Pica RD Safian JA Goldstein (1998) ArticleTitleEffect of reperfusion on biventricular function and survival after right ventricular infarction N Engl J Med 338 933–940 Occurrence Handle10.1056/NEJM199804023381401 Occurrence Handle1:STN:280:DyaK1c7nt12mtw%3D%3D Occurrence Handle9521980

    Article  CAS  PubMed  Google Scholar 

  • SR Mehta JW Eikelboom MK Natarajan et al. (2001) ArticleTitleImpact of right ventricular involvement on mortality and morbidity in patients with inferior myocardial infarction J Am Coll Cardiol 37 37–43 Occurrence Handle10.1016/S0735-1097(00)01089-5 Occurrence Handle1:STN:280:DC%2BD3M%2Fptl2hsg%3D%3D Occurrence Handle11153770

    Article  CAS  PubMed  Google Scholar 

  • RA Bleasdale MP Frenneaux (2002) ArticleTitlePrognostic importance of right ventricular dysfunction Heart 88 323–324 Occurrence Handle1:STN:280:DC%2BD38vntVOqsA%3D%3D Occurrence Handle12231578

    CAS  PubMed  Google Scholar 

  • NG Bellenger NJ Marcus C Davies M Yacoub NR Banner DJ Pennell (2000) ArticleTitleLeft ventricular function and mass after orthotopic heart transplantation: a comparison of cardiovascular magnetic resonance with echocardiography J Heart Lung Transplant 19 444–452 Occurrence Handle1:STN:280:DC%2BD3c3mvFOnsA%3D%3D Occurrence Handle10808151

    CAS  PubMed  Google Scholar 

  • JJ Sandstede M Beer S Hofmann et al. (2000) ArticleTitleChanges in left and right ventricular cardiac function after valve replacement for aortic stenosis determined by cine MR imaging J Magn Reson Imaging 12 240–246 Occurrence Handle1:STN:280:DC%2BD3cvlsV2ntQ%3D%3D Occurrence Handle10931586

    CAS  PubMed  Google Scholar 

  • J Scharhag G Schneider A Urhausen V Rochette B Kramann W Kindermann (2002) ArticleTitleAthlete’s heart: right and left ventricular mass and function in male endurance athletes and untrained individuals determined by magnetic resonance imaging J Am Coll Cardiol 40 1856–1863 Occurrence Handle12446071

    PubMed  Google Scholar 

  • PS Hees JL Fleg EG Lakatta EP Shapiro (2002) ArticleTitleLeft ventricular remodeling with age in normal men versus women: novel insights using three-dimensional magnetic resonance imaging Am J Cardiol 90 1231–1236 Occurrence Handle12450604

    PubMed  Google Scholar 

  • SG Myerson NG Bellenger DJ Pennell (2002) ArticleTitleAssessment of left ventricular mass by cardiovascular magnetic resonance Hypertension 39 750–795 Occurrence Handle10.1161/hy0302.104674 Occurrence Handle1:CAS:528:DC%2BD38XisVehtrs%3D Occurrence Handle11897757

    Article  CAS  PubMed  Google Scholar 

  • JC Moon CH Lorenz JM Francis GC Smith DJ Pennell (2002) ArticleTitleBreath-hold FLASH and FISP cardiovascular MR imaging: left ventricular volume differences and reproducibility Radiology 223 789–797 Occurrence Handle12034951

    PubMed  Google Scholar 

  • NG Bellenger LC Davies JM Francis AJ Coats DJ Pennell (2000) ArticleTitleReduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance J Cardiovasc Magn Reson 2 271–278 Occurrence Handle1:STN:280:DC%2BD3MvpslyitQ%3D%3D Occurrence Handle11545126

    CAS  PubMed  Google Scholar 

  • LM Panepinto RW Phillips (1986) ArticleTitleThe Yucatan miniature pig: characterization and utilization in biomedical research Lab Anim Sci 36 344–347 Occurrence Handle1:STN:280:DyaL2s%2Fjslyltw%3D%3D Occurrence Handle3534436

    CAS  PubMed  Google Scholar 

  • DJ Pennell (2002) ArticleTitleVentricular volume and mass by CMR J Cardiovasc Magn Reson 4 507–513 Occurrence Handle12549238

    PubMed  Google Scholar 

  • S Delepine AP Furber F Beygui et al. (2003) ArticleTitle3-D MRI assessment of regional left ventricular systolic wall stress in patients with reperfused MI Am J Physiol Heart Circ Physiol 284 H1190–H1197 Occurrence Handle1:CAS:528:DC%2BD3sXjtlylur4%3D Occurrence Handle12388295

    CAS  PubMed  Google Scholar 

  • A Furber P Balzer C Cavaro-Menard et al. (1998) ArticleTitleExperimental validation of an automated edge-detection method for a simultaneous determination of the endocardial and epicardial borders in short-axis cardiac MR images: application in normal volunteers J Magn Reson Imaging 8 1006–1014 Occurrence Handle1:STN:280:DyaK1M%2FgtVSktw%3D%3D Occurrence Handle9786136

    CAS  PubMed  Google Scholar 

  • JM Bland DG Altman (1986) ArticleTitleStatistical methods for assessing agreement between two methods of clinical measurement Lancet 1 307–310 Occurrence Handle1:STN:280:DyaL287hslWqsQ%3D%3D Occurrence Handle2868172

    CAS  PubMed  Google Scholar 

  • CH Lorenz ES Walker TP Graham SuffixJr PA Towers (1995) ArticleTitleRight ventricular performance and mass by use of cine MRI late after atrial repair of transposition of the great arteries Circulation 92 IssueIDSuppl. 9 II233–II239 Occurrence Handle1:STN:280:DyaK28%2FmvFajtQ%3D%3D Occurrence Handle7586415

    CAS  PubMed  Google Scholar 

  • WA Helbing SA Rebergen C Maliepaard et al. (1995) ArticleTitleQuantification of right ventricular function with magnetic resonance imaging in children with normal hearts and with congenital heart disease Am Heart J 130 828–837 Occurrence Handle1:STN:280:DyaK28%2FitFahsw%3D%3D Occurrence Handle7572593

    CAS  PubMed  Google Scholar 

  • C. Oakley (1998) ArticleTitleImportance of right ventricular function in congestive heart failure Am J Cardiol 62 14A–19A

    Google Scholar 

  • PA Davlouros PJ Kilner TS Hornung et al. (2002) ArticleTitleRight ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction J Am Coll Cardiol 40 2044–2052 Occurrence Handle12475468

    PubMed  Google Scholar 

  • SG Myerson HE Montgomery MJ World DJ Pennell (2002) ArticleTitleLeft ventricular mass: reliability of M-ode and 2-dimensional echocardiographic formulas Hypertension 40 673–678 Occurrence Handle10.1161/01.HYP.0000036401.99908.DB Occurrence Handle1:CAS:528:DC%2BD38XotFWltLk%3D Occurrence Handle12411461

    Article  CAS  PubMed  Google Scholar 

  • N Aebischer R Meuli X Jeanrenaud J Koerfer L Kappenberger (1998) ArticleTitleAn echocardiographic and magnetic resonance imaging comparative study of right ventricular volume determination Int J Card Imaging 14 271–278 Occurrence Handle1:STN:280:DyaK1M7jtlekug%3D%3D Occurrence Handle9934615

    CAS  PubMed  Google Scholar 

  • S Rees J Somerville C Warnes et al. (1988) ArticleTitleComparison of magnetic resonance imaging with echocardiography and radionuclide angiography in assessing cardiac function and anatomy following Mustard’s operation for transposition of the great arteries Am J Cardiol 61 1316–1322 Occurrence Handle1:STN:280:DyaL1c3jvVCntg%3D%3D Occurrence Handle3376893

    CAS  PubMed  Google Scholar 

  • F Grothues GC Smith JC Moon et al. (2002) ArticleTitleComparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy Am J Cardiol 90 29–34 Occurrence Handle10.1016/S0002-9149(02)02381-0 Occurrence Handle12088775

    Article  PubMed  Google Scholar 

  • V Schulen F Schick J Loichat et al. (1996) ArticleTitleEvaluation of K-space segmented cine sequences for fast functional cardiac imaging Invest Radiol 31 512–522 Occurrence Handle1:STN:280:DyaK2s%2Fgs12hsQ%3D%3D Occurrence Handle8854198

    CAS  PubMed  Google Scholar 

  • KM McDonald T Parrish P Wennberg et al. (1992) ArticleTitleRapid, accurate and simultaneous noninvasive assessment of right and left ventricular mass with nuclear magnetic resonance imaging using the snapshot gradient method J Am Coll Cardiol 19 1601–1607 Occurrence Handle10.1016/0735-1097(92)90625-W Occurrence Handle1:STN:280:DyaK383ns1Kqug%3D%3D Occurrence Handle1534337

    Article  CAS  PubMed  Google Scholar 

  • H Thiele I Paetsch B Schnackenburg et al. (2002) ArticleTitleImproved accuracy of quantitative assessment left ventricular volume and ejection fraction by geometric models with steady-state free precession J Cardiovasc Magn Reson 4 327–339 Occurrence Handle10.1081/JCMR-120013298 Occurrence Handle12234104

    Article  PubMed  Google Scholar 

  • K Alfakih H Thiele S Plein GJ Bainbridge JP Ridgway MU Sivananthan (2002) ArticleTitleComparison of right ventricular volume measurements between segmented K-space gradient-echo and steady-state free precession magnetic resonance imaging J Magn Reson Imaging 16 253–258 Occurrence Handle10.1002/jmri.10164 Occurrence Handle12205580

    Article  PubMed  Google Scholar 

  • MB Rominger GF Bachmann W Pabst WS Rau (1999) ArticleTitleRight ventricular volumes and ejection fraction with fast cine MR imaging in breath-hold technique: applicability, normal values from 52 volunteers, and evaluation of 325 adult cardiac patients J Magn Reson Imaging 10 908–918 Occurrence Handle1:STN:280:DC%2BD3c%2FltVemsA%3D%3D Occurrence Handle10581503

    CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Farzin Beygui.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Beygui, F., Furber, A., Delépine, S. et al. Routine breath-hold gradient echo MRI-derived right ventricular mass, volumes and function: accuracy, reproducibility and coherence study. Int J Cardiovasc Imaging 20, 509–516 (2004). https://doi.org/10.1007/s10554-004-1097-7

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-004-1097-7

Keywords

Navigation