Skip to main content
Log in

A Robust Method for Detecting the QRS Complex of the ECG Signal

  • Published:
Biomedical Engineering Aims and scope

This work was devoted to a robust method for detection of the QRS complex of the ECG signal based on the application of a band-pass filter with a linear phase characteristic, the Hilbert transform, and an adaptive threshold- ing algorithm. The efficiency of various QRS complex detectors in the presence of pronounced artifacts was studied. The efficiency of the suggested method was verified using different ECG records available from the MIT PhysioNet open access database.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Fedotov A.A., Akulov S.A., Mathematical Modeling and Analysis of Errors of Measuring Transducers of Biomedical Signals [in Russian], Fizmatlit, Moscow (2013).

    Google Scholar 

  2. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology, Circulation, 93, No. 5, 1043-1065 (1996).

  3. Friesen G.M. et al., IEEE Trans. Biomed. Eng., 27, No. 1, 85-98 (1990).

    Article  Google Scholar 

  4. Tompkins W.J. (Ed.), Biomedical Digital Signal Processing: C Language Examples and Laboratory Experiments for the IBM PC, Prentice Hall, New Jersey (1993).

    Google Scholar 

  5. Theis F.J., Meyer-Bäse A., Biomedical Signal Analysis: Contemporary Methods and Applications, MIT Press (2010).

  6. Mohamed E. et al., Proc. 3rd Int. Conf. Bio-Inspired Systems and Signal Processing (2010), pp. 428-431.

  7. Fedotov A.A., Akulova A.S., Akulov S.A., Izmer. Tekh., No. 11, 65-68 (2014).

  8. Benitez D. et al., Comput. Biol. Med., 31, 399-406 (2001).

    Article  Google Scholar 

  9. Rangayyan R.M., Biomedical Signal Analysis [Russian translation], Fizmatlit, Moscow (2007).

    Google Scholar 

  10. Moody G.B., Mark R.G., IEEE Eng. Med. Biol., 20, No. 3, 45-50 (2001).

    Article  Google Scholar 

  11. Pan J., Tompkins W.J., IEEE Trans. Biomed. Eng., 32, 230-236 (1985).

    Article  Google Scholar 

  12. Ruha A., Sallinen S., Nissila S., IEEE Trans. Biomed. Eng., 44, No. 3, 159-167 (1997).

    Article  Google Scholar 

  13. Kadambe S., Murray R. et al., IEEE Trans. Biomed. Eng., 46, No. 7, 838-848 (1999).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. A. Fedotov.

Additional information

Translated from Meditsinskaya Tekhnika, Vol. 50, No. 1, Jan.-Feb., 2016, pp. 28-31.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fedotov, A.A. A Robust Method for Detecting the QRS Complex of the ECG Signal. Biomed Eng 50, 40–43 (2016). https://doi.org/10.1007/s10527-016-9583-5

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10527-016-9583-5

Navigation