Abstract
Computational modeling is an effective way to predict the response of complex systems to perturbations that are difficult or impossible to measure experimentally. A computational model of the human elbow was developed wherein joint function was dictated by three-dimensional osteoarticular interactions, soft tissue constraints, muscle action, and external loading. The model was validated against two cadaveric experiments that examined the significance of coronoid process (CP) fractures, lateral ulnar collateral ligament (LUCL) ruptures, and radial head (RH) resection in varus stability. The model was able to accurately reproduce the trend of decreasing resistance to varus displacement with increased CP resection, with a significant drop in stability observed at >50% resection. In addition, the model showed that isolated repair of either the LUCL or RH conferred significant varus stability to the joint in the presence of a deficient coronoid, with the ligament responsible for the greatest increase in stability. Predicted magnitudes of joint contact force support claims that the ulnohumeral articulation is the most significant osseous stabilizer of the joint in varus, with the radiohumeral articulation having an increased role with increasing coronoid resection at low flexion angles. With confidence in the predictive ability of this computational model, future simulations could further investigate joint function under other loading scenarios and injury states.
Similar content being viewed by others
References
ADAMS/Solver User’s Guide. USA: MSC Software Corp., 2006.
Beggs, J. S., In: Kinematics, edited by Anonymous. Washington: Hemisphere Pub. Corp., vol. 223, 1983.
Buchanan, T. S., S. L. Delp, and J. A. Solbeck. Muscular resistance to varus and valgus loads at the elbow. J. Biomech. Eng. 120(5):634–639, 1998.
Fern, S. E., J. R. Owen, N. J. Ordyna, J. S. Wayne, and N. D. Boardman. Complex varus elbow instability: a terrible triad model. J. Should. Elb. Surg. 18(2):269–274, 2009.
Fisk, J. P., and J. S. Wayne. Development and validation of a computational musculoskeletal model of the elbow joint. In: Biomedical Engineering. Richmond: Virginia Commonwealth University, 2007, p. 144.
Fisk, J. P., and J. S. Wayne. Development and validation of a computational musculoskeletal model of the elbow and forearm. Ann. Biomed. Eng. 37(4):803–812, 2009.
Fornalski, S., R. Gupta, and T. Q. Lee. Anatomy and biomechanics of the elbow joint. Sports Med. Arthrosc. Rev. 11(1):1, 2003.
Gabriel, M. T., H. J. Pfaeffle, K. J. Stabile, M. M. Tomaino, and K. J. Fischer. Passive strain distribution in the interosseous ligament of the forearm: implications for injury reconstruction. J. Hand Surg. 29(2):293–298, 2004.
Garner, B. A., and M. G. Pandy. A kinematic model of the upper limb based on the visible human project (VHP) image dataset. Comput. Methods Biomech. Biomed. Eng. 2(2):107–124, 1999.
Gear, C. W. The automatic integration of ordinary differential equations. Commun. ACM 14:176–179, 1971.
Gonzalez, R. V., L. D. Abraham, and R. E. Barr. Muscle activity in rapid multi-degree-of-freedom elbow movements: solutions from a musculoskeletal model. Biol. Cybern. 80(5):357–367, 1999.
Gonzalez, R. V., E. L. Hutchins, and R. E. Barr. Development and evaluation of a musculoskeletal model of the elbow joint complex. J. Biomech. Eng. 118(1):32–40, 1996.
Hildebrand, K. A., S. D. Patterson, and G. J. King. Acute elbow dislocations simple and complex. Orthop. Clin. N. Am. 30(1):63–79, 1999.
Hotchkiss, R. N., K. N. An, D. T. Sowa, S. Basta, and A. J. Weiland. An anatomic and mechanical study of the interosseous membrane of the forearm: pathomechanics of proximal migration of the radius. J. Hand Surg. 14(2 Pt 1):256–261, 1989.
Hull, J. R., J. R. Owen, S. E. Fern, J. S. Wayne, and N. D. Boardman. Role of the coronoid process in varus osteoarticular stability of the elbow. J. Should. Elb. Surg. 14(4):441–446, 2005.
Kumar, P., M. Oka, J. Toguchida, M. Kobayashi, E. Uchida, T. Nakamura, and K. Tanaka. Role of uppermost superficial surface layer of articular cartilage in the lubrication mechanism of joints. J. Anat. 199(3):241–250, 2001.
Kwak, S. D., J. Blankevoort, and G. A. Ateshian. A mathematical formulation for 3D quasi-static multibody models of diarthrodial joints. Comput. Methods Biomech. Biomed. Eng. 3(1):41–64, 2000.
Liacouras, P. C., and J. S. Wayne. Computational modeling to predict mechanical function of joints: application to the lower leg with simulation of two cadaver studies. J. Biomech. Eng. 129(6):811–817, 2007.
Martin, C. H., and D. H. Lee. Explor® Modular Radial Head: Surgical Technique. Warsaw, IN: Biomet Orthopedics, Inc., 2008.
Morrey, B. F. The Elbow and Its Disorders. Philadelphia: W.B. Saunders, p. 933, 2000.
Morrey, B. F., and K.-N. An. Stability of the elbow: osseous constraints. J. Should. Elb. Surg. 14(1 Suppl):S174–S178, 2005.
Morrey, B. F., and R. C. Thompson Jr. Master Techniques in Orthopaedic Surgery: The Elbow. Philidephia, PA: Lippincott Williams & Williams, p. 432, 2002.
Noda, K., A. Goto, T. Murase, K. Sugamoto, H. Yoshikawa, and H. Moritomo. Interosseous membrane of the forearm: an anatomical study of ligament attachment locations. J. Hand Surg. 34(3):415–422, 2009.
Pfaeffle, H. J., M. M. Tomaino, R. Grewal, J. Xu, N. D. Boardman, S. L.-Y. Woo, and J. H. Herndon. Tensile properties of the interosseous membrane of the humanforearm. J. Orthop. Res. 14:842–845, 1996.
Radin, E. L., and I. L. Paul. A consolidated concept of joint lubrication. J. Bone Joint Surg. Am. 54:607–616, 1972.
Regan, W. D., S. L. Korinek, and B. F. Morrey. Biomechanical study of ligaments around the elbow joint. Clin. Orthop. Relat. Res. 271:170–179, 1991.
Ring, D., J. B. Jupiter, and J. Zilberfarb. Posterior dislocation of the elbow with fractures of the radial head and coronoid. J. Bone Joint Surg. 84(4):547–551, 2002.
Schuind, A., et al. The distal radioulnar ligaments: a biomechanical study. J. Hand Surg. 16(6):1106–1114, 1991.
Werner, F. W., and A. K. Palmer. The triangular fibrocartilage complex of the wrist–anatomy and function. J. Hand Surg. 6(2):153–162, 1981.
Acknowledgments
The authors would like to thank Dr. Curtis Hayes and the Department of Radiology at Virginia Commonwealth University for their assistance with the CT image captures.
Author information
Authors and Affiliations
Corresponding author
Additional information
Associate Editor Eiji Tanaka oversaw the review of this article.
Rights and permissions
About this article
Cite this article
Spratley, E.M., Wayne, J.S. Computational Model of the Human Elbow and Forearm: Application to Complex Varus Instability. Ann Biomed Eng 39, 1084–1091 (2011). https://doi.org/10.1007/s10439-010-0224-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10439-010-0224-y