Abstract
The safety, efficacy and acceptability of an oscillating/rotating powered toothbrush was assessed in patients rehabilitated with fixed prostheses on implants. One hundred consecutive patients (aged 18–80; mean 56.3; 51 females), who met the inclusion/exclusion criteria and who participated in a regular annual recall scheme, were enrolled. They were instructed on how to use the powered toothbrush, as well as on classical interdental plaque control. The electric toothbrush had to be used twice daily for 2 min. The following periodontal parameters were measured at baseline and at 3 months, 6 months and 12 months: presence/absence of gingival and/or mucosal ulceration/desquamation; sulcus bleeding index; probing pocket depth; periodontal pocket-bleeding index and gingival recession. At 3 months and at the end of the study, patients completed a questionnaire concerning the overall acceptability and convenience of the powered toothbrush, as compared with their habitual manual toothbrush. A total of 80 patients completed the study. No dropouts were related to the use of the powered toothbrush. All parameters improved over the course of the study. The mean overall pocket depth decreased from 3.3 mm at baseline to 3.0 mm at 12 months, while the mean decrease in recession was 0.1 mm at 12 months. During the 1-year observation, there was a slight gain in periodontal attachment level. Gingival ulcerations were not observed at any point in the study. High scores for convenience and comfort of the powered toothbrush were reported, and the majority (95%) said that they would continue to use it for habitual oral hygiene. It is concluded that the powered toothbrush investigated is effective, safe and comfortable for patients rehabilitated by means of oral implant-supported prostheses.
Similar content being viewed by others
References
Brägger U, Burgin WB, Hammerle CH, Lang NP (1997) Associations between clinical parameters assessed around implants and teeth. Clin Oral Implants Res 8:412–421
Hellstadius K, Asman B, Gustafsson A (1993) Improved maintenance of plaque control by electrical toothbrushing in periodontitis patients with low compliance. J Clin Periodontol 20:235–237
Lekholm U, Ericsson I, Adell R, Slots J (1986) The condition of the soft tissues at tooth and fixture abutments supporting fixed bridges. J Clin Periodontol 13:558–562
Lindquist LW, Rockler B, Carlsson GE (1988) Bone resorption around fixtures in edentulous patients treated with mandibular fixed tissue integrated-prostheses. J Prosthet Dent 59:59–63
Lindquist LW, Carlsson GE, Jemt T (1996) A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss. Clin Oral Implants Res 7:329–336
Mühlemann HR, Son S (1971) Gingival sulcus bleeding – a leading sign in initial gingivitis. Helv Odontol Acta 15:107–113
Quirynen M, Vervliet E, Teerlinck J, Darius P, van Steenberghe D (1994) Medium- and long-term effectiveness of a counterrotational electric toothbrush on plaque removal, gingival bleeding and probing depth. Int J Periodontics Restorative Dent 14:365–377
Quirynen M, Bollen C, Willems G, van Steenberghe D (1994) Comparison of surface characteristics of six commercially pure titanium abutments. Int J Oral Maxillofac Implants 9:71–76
Quirynen M, De Soete M, van Steenberghe D (2002) Infectious risks for oral implants: a review of the literature. Clin Oral Implants Res 13:1–19
Roos-Jansåker AM, Renvert S, Egelberg J (2003) Treatment of peri-implant infections: a literature review. J Clin Periodontol 30:467–485
Schemehorn BR, Zwart AC (1996) The dentin abrasivity potential of a new electric toothbrush. Am J Dent 9:19–20
Stålnacke K, Söderfeldt B, Sjödin B (1995) Compliance in use of electric toothbrushes. Acta Odontol Scand 53:17–19
Tawse-Smith A, Duncan W, Payne AGT, Thomson WM, Wennström JL (2002) Relative effectiveness of powered and manual toothbrushes in elderly patients with implant-supported mandibular overdentures. J Clin Periodontol 29:275–280
Truhlar RS, Morris HF, Ochi S (2000) The efficacy of a counter-rotational powered toothbrush in the maintenance of endosseous dental implants. J Am Dent Assoc 131:101–107
Van der Velden U (1979) Probing force and the relationship of the probe tip to the periodontal tissues. J Clin Periodontol 6:106–114
van Steenberghe D (1997) Outcomes and their measurements in clinical trials of endosseous oral implants. Ann Periodontol 2:291–298
van Steenberghe D, Klinge B, Linden U, Quirynen M, Herrmann I Garpland C (1993) Periodontal indices around natural and titanium abutments: a longitudinal multicenter study. J Periodontol 64:538–541
Warren PR, Chater BV (1996) The role of the electric toothbrush in the control of plaque and gingivitis: A review of 5 years clinical experience with the Braun Oral-B Plaque Remover (D7) Am J Dent 9: S5–S11
Warren PR, Smith Ray T, Cugini M, Chater BV (2000) A practice-based study of a power toothbrush: assessment of effectiveness and acceptance. J Am Dent Assoc 131:389–394
Wennström JL, Bengazi F, Lekholm U (1994) The influence of the masticatory mucosa on the peri-implant soft tissue condition. Clin Oral Implants Res 5:1–8
Wilson TG Jr (1996) A typical maintenance visit for patients with dental implants. Periodontol 2000 12:29
Wolff L, Kim A, Nunn M, Bakdash B, Hinrichs J (1998) Effectiveness of a sonic toothbrush in maintenance of dental implants: A prospective study. J Clin Periodontol 25:821–828
Author information
Authors and Affiliations
Corresponding author
Additional information
D. van Steenberghe is the holder of the P-I Brånemark chair in osseointegration
Rights and permissions
About this article
Cite this article
Vandekerckhove, B., Quirynen, M., Warren, P.R. et al. The safety and efficacy of a powered toothbrush on soft tissues in patients with implant-supported fixed prostheses. Clin Oral Invest 8, 206–210 (2004). https://doi.org/10.1007/s00784-004-0278-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00784-004-0278-z