Evaluation of diagnostic reliability of DCA 2000 for rapid and simple monitoring of HbA1c

  • Original
  • Published:
Acta Diabetologica Aims and scope Submit manuscript

Abstract

The monitoring of diabetic patients by evaluating glycated protein levels is now widely accepted and performed. The microchromatographic version of the high performance liquid chromatography method is the technique most frequently used in clinical practice. The DCA 200 instrument (Bayer Diagnostics, Milan, Italy), based on an immunochemical technique, has been proposed for the rapid and simple evaluation of HbA1c, using even capillary blood. We evaluated 171 subjects including 22 healthy volunteers, 78 type 2 diabetic patients with different degrees of metabolic control, 11 women affected by gestational diabetes mellitus (GDM), 6 patients with hyperlipemia, 38 patients with chromic renal failure, 13 diabetic patients with chronic renal failure, and 3 patients with hemoglobinopathies. The DCA 2000 model was compared with the Diamat HPLC system. Data from within-run imprecision studies showed excellent precision, for both DCA 2000 and the HPLC system. The correlation between the two different systems, as shown by other statistical evaluations, was good (y = 0.911x + 0.462, r = 0.923). Results from the control group and diabetic patients were used to compare the two methods. Values obtained using the DCA 2000 were significantly lower (p < 0.0001) than those obtained with the HPLC system, in both healthy subjects and diabetic patients. To detect possible interferences, selected samples were analyzed from patients with hyperlipemia, diabetes and chronic renal failure, and hemoglobinopathies. While in the case of hyperlipemia, an acceptable correlation coefficient between the two systems was confirmed (y = 1.047x − 1.236, r = 0.876), in the case of chronic renal failure the correlation turned out to be very low (y = 0.254x + 3.456, r = 0.203). Our results indicate that the DCA 2000 gives accurate and reliable results in the clinical field of interest.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 20 July 1999 / Accepted in revised form: 3 March 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Arsie, M., Marchioro, L., Lapolla, A. et al. Evaluation of diagnostic reliability of DCA 2000 for rapid and simple monitoring of HbA1c. Acta Diabetol 37, 1–7 (2000). https://doi.org/10.1007/s005920070028

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s005920070028

Navigation