Abstract
We report the feasibility of transthoracic live three-dimensional echocardiography in the diagnosis of a thrombus attached to the mitral bioprosthetic valve.
Similar content being viewed by others
References
WG Daniel A Mugge J Grote D Hausmann P Nikutta J Laas PR Lichtlen RP Martin (1993) ArticleTitleComparison of transthoracic and transesophageal echocardiography for detection of abnormalities of prosthetic and bioprosthetic valves in the mitral and aortic position Am J Cardiol 71 210–215 Occurrence Handle8421985 Occurrence Handle10.1016/0002-9149(93)90740-4 Occurrence Handle1:STN:280:ByyC3srhtFA%3D
BK Khandheria JB Seward JK Oh WK Freeman BA Nichols LJ Sinak FA Miller SuffixJr AJ Tajik (1991) ArticleTitleValue and limitations of transesophageal echocardiography in assessment of mitral valve prostheses Circulation 83 1956–1968 Occurrence Handle2040048 Occurrence Handle1:STN:280:By6B2cbktlE%3D
N Sayar S Terzi HY Yilmaz H Atmaca F Kocak SU Dayi N Cakmak A Tarhan A Ozler K Yesilcimen (2006) ArticleTitleA case of prosthetic mitral valve Brucella endocarditis complicated with torsades de pointes Heart Vessels 21 331–333 Occurrence Handle17151824 Occurrence Handle10.1007/s00380-006-0907-3
L Sugeng L Weinert K Thiele RM Lang (2003) ArticleTitleReal-time three-dimensional echocardiography using a novel matrix array transducer Echocardiography 20 623–635 Occurrence Handle14536013 Occurrence Handle10.1046/j.1540-8175.2003.t01-1-03031.x
KL Chan X Liu KJ Ascah LM Beauchesne IG Burwash (2004) ArticleTitleComparison of real-time 3-dimensional echocardiography with conventional 2-dimensional echocardiography in the assessment of structural heart disease J Am Soc Echocardiogr 17 976–980 Occurrence Handle15337963 Occurrence Handle10.1016/j.echo.2004.05.005