CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease

  • Cardiac
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract

Objectives

To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD).

Methods

Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time × weight [kg] × 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard.

Results

The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV).

Conclusions

CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD.

Key Points

TAVI-planning CT using variable helical pitch (VHP) scanning is useful.

The average volume of contrast material was 38.7 ± 8.5 mL.

The average attenuations of all the arteries were >400 HU.

This CT had a high sensitivity and NPV for excluding obstructive CAD.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

Abbreviations

CAD:

Coronary artery diseasec

CAG:

Coronary angiography

CM:

Contrast material

CT:

Computed tomography

ECG:

Electrocardiogram

NPV:

Negative predictive value

PPV:

Positive predictive value

TAVI:

Transcatheter aortic valve implantation

References

  1. Webb JG, Wood DA (2012) Current status of transcatheter aortic valve replacement. J Am Coll Cardiol 60:483–492

    Article  PubMed  Google Scholar 

  2. Leon MB, Smith CR, Mack M et al (2010) Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 363:1597–1607

    Article  CAS  PubMed  Google Scholar 

  3. Smith CR, Leon MB, Mack MJ et al (2011) Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med 364:2187–2198

    Article  CAS  PubMed  Google Scholar 

  4. Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA (2012) SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 6:366–380

    Article  PubMed  Google Scholar 

  5. Yamamoto M, Hayashida K, Mouillet G et al (2013) Prognostic value of chronic kidney disease after transcatheter aortic valve implantation. J Am Coll Cardiol 62:869–877

    Article  PubMed  Google Scholar 

  6. Yamamoto M, Hayashida K, Mouillet G et al (2013) Renal function-based contrast dosing predicts acute kidney injury following transcatheter aortic valve implantation. JACC Cardiovasc Interv 6:479–486

    Article  PubMed  Google Scholar 

  7. Goel SS, Ige M, Tuzcu EM et al (2013) Severe aortic stenosis and coronary artery disease--implications for management in the transcatheter aortic valve replacement era: a comprehensive review. J Am Coll Cardiol 62:1–10

    Article  PubMed  Google Scholar 

  8. Harris BS, De Cecco CN, Schoepf UJ et al (2015) Dual-source CT imaging to plan transcatheter aortic valve replacement: accuracy for diagnosis of obstructive coronary artery disease. Radiology 275:80–88

    Article  PubMed  Google Scholar 

  9. Toggweiler S (2014) How to reduce costs in transcatheter aortic valve implantation. Open Heart 1:e000203

    Article  PubMed  PubMed Central  Google Scholar 

  10. Yamada Y, Jinzaki M, Hosokawa T et al (2012) Dose reduction in chest CT: comparison of the adaptive iterative dose reduction 3D, adaptive iterative dose reduction, and filtered back projection reconstruction techniques. Eur J Radiol 81:4185–4195

    Article  PubMed  Google Scholar 

  11. Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M Jr, Detrano R (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832

    Article  CAS  PubMed  Google Scholar 

  12. McCollough C, Cody D, Edyvean S et al (2008) The measurement, reporting, and management of radiation dose in CT. Rep AAPM Task Group 23:1–28

    Google Scholar 

  13. Fei X, Du X, Yang Q et al (2008) 64-MDCT coronary angiography: phantom study of effects of vascular attenuation on detection of coronary stenosis. AJR Am J Roentgenol 191:43–49

    Article  PubMed  Google Scholar 

  14. Hausleiter J, Meyer TS, Martuscelli E et al (2012) Image quality and radiation exposure with prospectively ECG-triggered axial scanning for coronary CT angiography: the multicenter, multivendor, randomized PROTECTION-III study. JACC Cardiovasc Imaging 5:484–493

    Article  PubMed  Google Scholar 

  15. Cademartiri F, Maffei E, Palumbo AA et al (2008) Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography. Eur Radiol 18:576–583

    Article  PubMed  Google Scholar 

  16. Azzalini L, Abbara S, Ghoshhajra BB (2014) Ultra-low contrast computed tomographic angiography (CTA) with 20-mL total dose for transcatheter aortic valve implantation (TAVI) planning. J Comput Assist Tomogr 38:105–109

    Article  PubMed  Google Scholar 

  17. Wuest W, Anders K, Schuhbaeck A et al (2012) Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode. Eur Radiol 22:51–58

    Article  CAS  PubMed  Google Scholar 

  18. Toggweiler S, Gurvitch R, Leipsic J et al (2012) Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure. J Am Coll Cardiol 59:113–118

    Article  PubMed  Google Scholar 

  19. Rodes-Cabau J, Webb JG, Cheung A et al (2010) Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. J Am Coll Cardiol 55:1080–1090

    Article  PubMed  Google Scholar 

  20. Kok M, Turek J, Mihl C et al (2015) Low contrast media volume in pre-TAVI CT examinations. Eur Radiol 1–10

  21. Dubourg B, Caudron J, Lestrat J-P et al (2014) Single-source dual-energy CT angiography with reduced iodine load in patients referred for aortoiliofemoral evaluation before transcatheter aortic valve implantation: impact on image quality and radiation dose. Eur Radiol 24:2659–2668

    Article  PubMed  Google Scholar 

  22. Staab W, Bergau L, Lotz J, Sohns C (2014) Prevalence of noncardiac findings in computed tomography angiography before transcatheter aortic valve replacement. J Cardiovasc Comput Tomogr 8:222–229

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

The scientific guarantor of this publication is Masahiro Jinzaki. Masahiro Jinzaki received a grant from Toshiba Medical Systems Japan. The remaining authors (Shunsuke Matsumoto, Yoshitake Yamada, Masahiro Hashimoto, Teppei Okamura, Minoru Yamada, Fumiaki Yashima, Kentaro Hayashida, and Keiichi Fukuda) have no financial disclosures to make and had complete unrestricted access to the study data at all stages of the study. The authors state that this work has not received any funding. No complex statistical methods were necessary for this paper.

Institutional review board approval was obtained. Written informed consent was obtained from all patients in this study. No study subjects or cohorts have been previously reported. Methodology: retrospective, diagnostic or prognostic study, performed at one institution.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Yoshitake Yamada or Masahiro Jinzaki.

Additional information

Shunsuke Matsumoto and Yoshitake Yamada contributed equally to this work.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Matsumoto, S., Yamada, Y., Hashimoto, M. et al. CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease. Eur Radiol 27, 1963–1970 (2017). https://doi.org/10.1007/s00330-016-4547-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00330-016-4547-4

Keywords

Navigation