Abstract
This retrospective study aims to evaluate radiation exposure by three-dimensional rotational angiography (3DRA) during trans-catheter Melody pulmonary valve (TMPV) procedures. 3DRA has been reported to have added value in the management of complex congenital heart disease aiding in the performance of interventional procedures albeit with concerns of higher radiation exposure. We test the hypothesis that 3DRA does not cause additional radiation exposure during TMPV procedures. We analyzed all 81 TMPV procedures performed at St. Louis Children’s Hospital, MO, USA, from January 1, 2011 to December 31, 2014. Dose-area product (DAP), DAP indexed to body weight (DAP/BW), fluoroscopy time (FT), and weight–fluoroscopy time product of each procedure were recorded. We reviewed each procedure’s images to determine whether additional interventions were performed (e.g., pulmonary artery angioplasty or treatment of conduit pseudo-aneurysm). 3DRA was used in 36 % of the procedures. 3DRA group had a higher number of additional procedures performed. The 3DRA group did not differ from the non-3DRA group in DAP, DAP/BW, and weight–fluoroscopy time product. 3DRA does not cause greater radiation exposure during TMPV procedures.
Similar content being viewed by others
References
Johnson JN, Hornik CP, Li JS, Benjamin DK, Yoshizumi TT, Reiman RE, Frush DP, Hill KD (2014) Cumulative radiation exposure and cancer risk estimation in children with heart disease. Circulation 130:161–167
Bacher K, Bogaert E, Lapere R, De Wolf D, Thierens H (2005) Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 111:83–89
Ghelani SJ, Glatz AC, Stuthi D, Leahy R, Hirsch R, Armsby LB, Trucco SM, Holzer RJ, Bergersen L (2014) Radiation dose benchmarks during cardiac catheterization for congenital heart disease in the United States. J Am Coll Cardiol Interv 7:1060–1069
Hijazi ZM, Awad SM (2008) Pediatric cardiac interventions. J Am Coll Cardiol Interv 1:603–611
Glatz AC, Zhu X, Gillespie J, Hanna BD, Rome JJ (2010) Use of angiographic CT imaging in the cardiac catheterization laboratory for congenital heart disease. J Am Coll Cardiol Imaging 3:1149–1157
Glockler M, Koch A, Greim V, Shabaiek A, Ruffer A, Cesnjevar R, Achenbach S, Dittrich S (2011) The value of flat-detector computed tomography during catheterization of congenital heart disease. Eur Radiol 21:2511–2520
Glockler M, Halbfass J, Koch A, Achenbach S, Dittrich S (2013) Multimodality 3D-roadmap for cardiovascular interventions in congenital heart disease: a single-center, retrospective analysis of 78 cases. Catheter Cardiovasc Interv 82:436–442
Fagan T, Kay J, Carroll J, Neubauer A (2012) 3-D guidance of complex pulmonary artery stent placement using reconstructed rotational angiography with live overlay. Catheter Cardiovasc Interv 79:414–421
Boothroyd A, McDonald E, Moores BM, Sluming V, Carty H (1997) Radiation exposure to children during cardiac catheterization. Br J Radiol 70:180–185
Rassow J, Schmaltz AA, Heintrich F, Steffer C (2000) Effective doses to patients from paediatric cardiac catheterization. Br J Radiol 73:172–183
Martinez LC, Vano E, Gutierrez F, Rodriguez C, Gilarranz R, Manzanas MJ (2007) Patient doses from fluoroscopically guided cardiac procedures in pediatrics. Phys Med Biol 52:4749–4759
Ubeda C, Vano E, Miranda P, Leyton F (2012) Pilot program on patient dosimetry in pediatric interventional cardiology in Chile. Med Phys 39:2424–2430
Chida K, Ohno T, Takegawa M, Yuuki H, Nakada M, Takahashi S, Zuguchi M (2010) Radiation doses to the pediatric cardiac catheterization and intervention patient. Am J Roent 195:1175–1179
Glatz AC, Patel A, Zhu X, Dori Y, Hanna BD, Gillespie MJ, Rome JJ (2014) Patient radiation exposure in a modern, large-volume, pediatric cardiac catheterization laboratory. Pediatr Cardiol 35:870–878
Verghese GR, McElhinney DB, Strauss KJ, Bergensen L (2012) Characterization of radiation exposure and effect of a radiation monitoring policy in a large volume pediatric cardiac catheterization lab. Catheter Cardiovasc Interv 79:294–301
Reinke G, Halbfass J, Dittrich S, Banckwitz R, Kohler C, Achenbach S, Rompel O, Glocker M (2013) Three-dimensional rotational angiography in congenital heart disease: estimation of radiation exposure. Open J Radiol 3:124–129
Manica JLL, Borges MS, de Medeiros RF, dos Santos Fischer L, Broetto G, Rossi Filho RI (2014) A comparison of radiation dose between standard and 3D angiography in congenital heart disease. Arq Bras Cardiol 103:131–137
Corredoira E, Vano E, Ubeda C, Gutierrez-Larraya F (2015) Patient doses in pediatric interventional cardiology: impact of 3D rotational angiography. J Radiol Prot 35:179–195
Peters M, Krings G, Koster M, Molenschot M, Freund MW, Breur JMPJ (2015) Effective radiation dosage of three-dimensional rotational angiography in children. Europace 17:611–616
Kapins CEB, Coutinho RB, Barbosa FB, Silva CMC, Lima VC, Carvalho AC (2010) Use of 3D rotational angiography in congenital heart disease: experience with 53 patients. Rev Bras Cardiol Invasiva 18:199–203
Berman DP, Khan DM, Gutierrez Y, Zahn EM (2012) The use of three-dimensional rotational angiography to assess the pulmonary circulation following cavo-pulmonary connection in patients with single ventricle. Catheter Cardiovasc Interv 80:922–930
Kobayashi D, Meadows J, Forbes TJ, Moore P, Javois AJ, Pedra CA, Du W, Gruenstein DH, Wax DF, Hill JA, Graziano JN, Fagan TE, Alvarez WM, Nykanen DG, Divekar AA (2014) Standardizing radiation dose reporting in the pediatric cardiac catheterization laboratory: a multicenter study by the CCISC (Congenital Cardiovascular Interventional Study Consortium). Catheter Cardiovasc Interv 84:785–793
Acknowledgments
The authors thank Dr. Toby Rockefeller for his critical reading of this manuscript.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
Dr. Balzer is a proctor for Medtronic. The remaining authors have no financial relationships relevant to this article to disclose. The authors have indicated they have no potential conflicts of interest to disclose.
Rights and permissions
About this article
Cite this article
Nguyen, H.H., Balzer, D.T., Murphy, J.J. et al. Radiation Exposure by Three-Dimensional Rotational Angiography (3DRA) During Trans-catheter Melody Pulmonary Valve Procedures (TMPV) in a Pediatric Cardiac Catheterization Laboratory. Pediatr Cardiol 37, 1429–1435 (2016). https://doi.org/10.1007/s00246-016-1453-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00246-016-1453-0