Summary
Clinical quantitation of regional myocardial perfusion using a minimally invasive and easily applied technique could allow for ready quantitation of the functional significance of coronary disease, allow for further understanding of flow reserve in various cardiomyopathic and hemodynamic overload (pressure versus volume) conditions, and possibly provide basic information needed regarding the development and clinical significance of coronary collateral vessels and diseases of the myocardial microcirculation. Electron beam CT (EBCT) is a unique cardiac imaging modality that allows for rapid acquisition tomographic slices of the heart with excellent spatial resolution. It has been demonstrated to provide accurate measurements of cardiac anatomy, biventricular function, myocardial mass, and estimates of mural atherosclerotic plaque burden via quantification of coronary calcium. The application of classical indicator techniques for use by fast x-ray computed tomography techniques such as electron beam CT has been shown to allow quantitative analysis of regional myocardial perfusion throughout the myocardium. Initial studies using central intravenous contrast injection in experimental animals showed a close correlation of regional myocardial perfusion as quantitated by electron beam CT with measurements using radiolabeled microspheres at resting and moderately increased flow states. At high flow states, however, electron beam CT significantly underestimated absolute myocardial perfusion and thus myocardial flow reserve. Using another fast CT device, the Dynamic Spatial Reconstructor (DSR), concepts of intramyocardial vascular blood volume and its relation to myocardial flow have been established. By adapting these concepts to electron beam CT scanning and accounting for the increase in intramyocardial vascular blood volume at vasodilatation, the ability to correctly quantitate perfusion states up to approximately 400 mL · min−1 · 100 g−1 using central intravenous contrast administration was demonstrated. This implies that studies can be done with intravenous injection methods for characterization of regional myocardial perfusion up to the normal flow reserve of approximately 4∶1. Important physiologic and clinical abnormalities in flow reserve generally result in a ratio <3∶1. Electron beam CT offers the capability to quantitate regional myocardial perfusion in both the clinical and research setting. Of particular interest is the ability to provide quantitative regional myocardial perfusion which can be coupled to the evaluation of cardiac anatomy and function as well as mural coronary atherosclerotic calcium burden during the same scanning session. Thus, electron beam CT has the potential to become a valuable, minimally invasive clinical tool for comprehensive analysis of cardiac function and coronary status.
Zusammefassung
Eine minimal invasive und leicht anwendbare Methode zur quantitativen Bestimmung der regionalen Myokardperfusion wäre von großer Bedeutung in der klinischen Praxis. Die quantitative Beurteilung der physiologischen Bedeutung von Koronarstenosen wäre genauso möglich wie ein genaueres Verständnis der koronaren Flußreserve bei verschiedenen Kardiomyopathien oder Krankheitsbildern mit hämodynamischer Belastung (zum Beispiel Verschiebung der Druck-Volumen-Beziehung mit Overload). Ein wichtiger Aspekt ist auch die Aussicht, eine bessere Vorstellung von der Ausprägung und klinischen Bedeutung koronarer Koilateralgefäße sowie von Erkrankungen der koronaren Mikrozirkulation zu erhalten. Die Elektronenstrahltomographie (EBCT) ist ein einzigartiges Verfahren in der kardialen Bildgebung, das ultraschnelle Schichtbildaufnahmen des Herzens mit einer herausragenden räumlichen Auflösung in rascher Folge ermöglicht. Diese Methode ermöglicht exakte Aussagen zur Anatomie, biventrikulären Funktion und Muskeimasse des Herzens sowie zum Ausmaß der koronaren atherosklerotischen Plaquebildung mittels Quantifizierung koronarer Kalkablagerungen. Mittels Anwendung der klassischen Indikator-Verdünnungstheorie im Bereich der ultraschnellen CT-Methoden wie Elektronenstrahltomographie gelingt die quantitative Analyse der regionalen Myokardperfusion. In den ersten tierexperimentellen Studien zur Bestimmung der Myokardperfusion mittels Elektronenstrahltomographie wurde Kontrastmittel zentralvenös injiziert. Es zeigte sich eine sehr genaue Übereinstimmung der ermittelten quantitativen Werte für die Myokardperfusion im Vergleich zu der Standardtechnik, radiomarkierten Mikrosphären. Dies galt jedoch nur für Zustände mit reduzierter, normwertiger oder gering-bis mäßiggradig erhöhter Perfusion. während die Myokardper fusion bei maximaler Hyperämie deutlich zu niedrig bestimmt wurde, so daß auch die koronare Flußreserve als zu gering angegeben wurde. Mit einer anderen, ausschließlich in der Forschung verwendeten ultraschnellen CT-Methode, dem Dynamic Spatial Reconstructor (DSR), wurde das Konzept des intramyokardialen vaskulären Blutvolumens und seine Relation zum myokardialen Blutfluß etabliert. In der Folge wurde dann berichtet, daß nach Berücksichtigung der Zunahme des intramyokardialen vaskulären Blutvolumens bei maximaler Hyperämie die regionale Myokardperfusion bis zu etwa 400 ml · min−1 · 100 g−1 präzise mit Elektronenstrahltomographie und zentral intravenöser Kontrastmittelgabe bestimmt werden konnte. Dies zeigt, daß eine Quantifizierung der regionalen Myokardperfusion mittels Elektronenstrahltomographie bis zu einer normalen koronaren Flußreserve von etwa 4∶1 mit zentral intravenöser Kontrastmittelgabe durchgeführt werden kann. Physiologisch und klinisch bedeutsame Einschränkungen der koronaren Flußreserve führen gewöhnlich zu einem Wert <3∶1. Die Elektronenstrahltomographie ermöglicht die quantitative Bestimmung der regionalen Myokardperfusion in der klinischen Praxis und in Forschungsvorhaben. Insbesonders kann die quantitative Analyse der regionalen Myokardperfusion mit der Untersuchung von Anatomie und Funktion des Herzens sowie dem Ausmaß koronarer Kalkablagerungen als Zeichen atherosklerotischer Plaquebildung verbunden werden. Elektronenstrahltomographie ist ein vielversprechendes minimal invasives Verfahren, das eine umfassende Untersuchung der kardialen Funktion und des Koronarkreislaufs in der klinischen Praxis ermöglichen kann.
Similar content being viewed by others
References
Baumgart, D., A. Schmermund, G. Görge et al: Comparison of Electron Beam Computed Tomography with Intracoronary Ultrasound and Coronary Angiography for the Detection of Coronary Atherosclerosis. J. Amer. Coll. Cardiol. (in press).
Bell, M. R., J. A. Rumberger, A. W. Stanson, P. F. Sheedy: Rapid and minimally invasive measurement of myocardial flow reserve in man with ultrafast CT. Circulation 84 (1991), II-678 (Abstract).
Boyd, D. B.: Computerized transmission tomography of the heart using scanning electron beams. In: Higgins, C. H. (ed.): Computed tomography of the heart and great vessels. Futura Publishing, New York 1983, p. 45–52.
Erbel, R., J. Ge, A. Bockisch, P. Kearney, G. Görge, M. Haude, D. Schümann, J. Zamorano, H. J. Rupprecht, J. Meyer: Value of intracoronary ultrasound and Doppler in the differentiation of angiographically normal coronary arteries: a prospective study inpatients with angina pectoris. Europ. Heart J. 17 (1996), 880–889.
Feiring, A. J., J. A. Rumberger, S. J. Reiter, D. J. Skorton, S. M. Collins, M. J. Lipton: Determination of left ventricular mass in dogs with rapid-acquisition cardiac computed tomographic scanning. Circulation 72 (1985), 1355–1364.
Feiring, A. J., J. A. Rumberger, S. J. Reiter, S. M. Collins, D. J. Skorton, M. Rees, M. L. Marcus: Sectional and segmental variability of left ventricular function: experimental and clinical studies using ultrafast computed tomography. J. Amer. Coll. Cardiol. 12 (1988), 415–425.
Garrett, J. S., P. Lanzer, W. Janchke, M. J. Lipton: Measurement of cardiac output by cine computed tomography. Amer. J. Cardiol. 56 (1985), 657–661.
Hounsfield, G. N.: Picture quality of computed tomography. Amer. J. Roentgenol. 127 (1976), 3–9.
Iida, H., I. Kanno, A. Takahashi, S. Miura, M. Murakami, K. Takahashi, Y. Ono, F. Shishido, A. Inugami, N. Tomura: Measurement of absolute myocardial blood flow with H2O15 and dynamic positron-emission tomography: Strategy for quantification in relation to the partial-volume effect. Circulation 78 (1988), 104–115.
Jaschke, W., R. G. Gould, P. A. Assimakopoulos, M. J. Lipton: Flow measurements with a high-speed computed tomography scanner. Med. Phys. 14 (1987), 238–243.
Liu, Y.-H., R. C. Bahn, E. L. Ritman: Microvascular blood volume-to-flow relationship in poreine heart wall: whole body CT evaluation in vivo. Amer. J. Physiol. 269 (1995) (Heart Circ. Physiol. 38), H1820-H1826.
Morgenstern, C., U. Holjes, G. Arnold, W. Lochner: The influence of coronary pressure and coronary flow on intracoronary blood volume angiometry of the left ventricle. Pflügers Arch. 340 (1973), 101–111.
Newman, E. V., M. Merrell, A. Genecin, C. Monge, W. R. Milnor, W. P. McEver: The dye dilution method for describing the central circulation: An analysis of factors shaping the time-concentration curves. Circulation 4 (1951), 735–746.
Rees, M. J., A. J. Feiring, J. A. Rumberger, R. M. MacMillan, D. L. Clark: Heart evaluation by cine-CT: Use of two new oblique views. Radiology 159 (1986), 804–809.
Reiter, S. J., J. A. Rumberger, A. J. Feiring, W. Stanford, M. L. Marcus. Precision of right and left ventricular stroke volume measurements by cine computed tomography. Circulation 74 (1986), 890–900.
Ritman, E. L., R. A. Robb, E. H. Wood: Synchronous volumetric imaging for noninvasive vivisection of cardiovascular and respiratory dynamics: evolution and current perspectives. In: Giuliani, E. R., V. Fuster, B. J. Gersh, M. D. McGoon, D. C. McGoon: Cardiology. Fundamentals and practice. Mosby Year Book. St. Louis 1991, p. 399–414.
Rumberger, J. A., A. J. Feiring, M. J. Lipton, C. B. Higgins, S. R. Ell, M. L. Marcus: Use of ultrafast computed tomography to quantitate regional myocardial perfusion: A preliminary report. J. Amer. Coll. Cardiol. 9 (1987), 59–69.
Rumberger, J. A., W. Stanford, M. L. Marcus: Quantitation of regional myocardial perfusion by ultrafast-CT: Promises and pitfalls. Amer. J. Cardiac Imag. 1 (1987), 336–343.
Rumberger, J. A., R. M. Weiss, A. J. Feiring, W. Stanford, Z. D. Hajduczok, K. Rezai, M. L. Marcus: Patterns of regional diastolic function in the normal human left ventricle: An ultrafast computed tomographic study. J. Amer. Coll. Cardiol. 14 (1989), 119–126.
Rumberger, J. A., D. B. Simons, L. A. Fitzpatrick, P. F. Sheedy, R. S. Schwartz: Coronary artery calcium areas by electron beam computed tomography and coronary atherosclerotic plaque area: A histopathologic correlative study. Circulation 92 (1995), 2157–2162.
Rumberger, J. A., M. R. Beli: Measurement of myocardial perfusion using electron-beam (ultrafast) computed tomography. In: Skorton, D. J., H. R. Schelbert, G. L. Wolf, B. H. Brundage (eds.): Marcus Cardiac Imaging. W. B. Saunders, Philadelphia 1996, p. 835–852.
Siegelman, S. S.: Editor’s page. Radiology 186 (1993), 36.
Wang, T., X. Wu, N. Chung, E. L. Ritman: Myocardial blood flow quantitated by synchronous, multi-slice, high-speed computer tomography. IEEE Transact. med. Imag. 8 (1989), 70–77.
Weiss, H. R., M. M. Winbury: Nitroglycerin and chromonar on small-vessel blood content of the ventricular wall. Amer. J. Physiol. 226 (1974), 838–843.
Weiss, R. M., E. A. Otoadese, M. P. Noel, S. C. DeJong, S. D. Heery: Quantitation of absolute regional myocardial perfusion using cine computed tomography. J. Amer. Coll. Cardiol. 23 (1994), 1186–1193.
Wilson, R. F., D. E. Laughlin, P. H. Ackell, W. M. Chilian, M. D. Holida, C. J. Hartley, M. L. Armstrong: Transluminal subseiective measurement of coronary artery blood flow velocity and vasodilator reserve in man. Circulation 72 (1985), 82–92.
Wolfkiel, C. J., J. L. Ferguson, E. V. Chomka, W. R. Law, I. N. Labin, M. L. Tenzer, M. Booker, B. H. Brundage: Measurement of myocardial blood flow by ultrafast computed tomography. Circulation 76 (1987), 1262–1273.
Wolfkiel, C. J., J. L. Ferguson, E. V. Chomka, B. H. Brundage: Determination of cardiac output by ultrafast computed tomography. Amer. J. cardiac Imag. 1 (1987), 117–122.
Wu, X., D. L. Ewert, Y.-H. Liu, E. L. Ritman: In vivo relation of intramyocardial blood volume to myocardial perfusion. Evidence supporting microvascular site for autoregulation. Circulation 85 (1992), 730–737.
Ziegler, W. H., C. A. Goresky: Transcapillary exchange in the working left ventricle of the dog. Circulat. Res. 24 (1971), 181–207.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Schmermund, A., Bell, M.R., Lerman, L.O. et al. Quantitative Evaluation of Regional myocardial perfusion using fast X-ray computed tomography. Herz 22, 29–39 (1997). https://doi.org/10.1007/BF03044568
Issue Date:
DOI: https://doi.org/10.1007/BF03044568