Skip to main content
Log in

The New Jersey low-contact-stress knee replacement system: Biomechanical rationale and review of the first 123 cemented cases

  • Original Articles
  • Published:
Archives of orthopaedic and traumatic surgery Aims and scope Submit manuscript

Summary

A mobile-bearing element, metal-backed, interchangeable knee replacement system has been designed to combine low constraint forces with low contact stresses (LCS), allowing nearly normal joint articulation and loading as well as long-term wear resistance of the implants. The system is versatile, including a large number of component options in variable sizes, and it may be used in both primary and revision arthroplasties. The overall results in the first 123 cemented cases (97 patients) with 2- to 7-year follow-up (average 3.7 years) were good to excellent in 88.6%, fair in 3.3%, and poor in 8.1%. Fair and poor results were seen predominantly in multiply operated and implant revision cases. The best results were noted in primary cases, 97.4% of which had good to excellent results. There have been no mechanical implant failures and no meniscal bearing dislocations in this series. Pain relief and restoration of function have been very gratifying with this system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bourne RB, Goodfellow JW, O'Connor JJ (1978) A functional analysis of various knee arthroplasties. Presented at the 24th Annual Meeting of the Orthopaedic Research Society, Dallas

  2. Buechel FF (1982) A simplified evaluation system for the rating of knee function. Orthop Rev 11:97

    Google Scholar 

  3. Cameron HU, Hunter GA (1982) Failure in total knee arthroplasty: mechanisms, revisions, and results. Clin Orthop 170:141

    Google Scholar 

  4. Glynn MK, Sheehan JM (1983) An analysis of the causes of deep infection after hip and knee arthroplasties. Clin Orthop 178:202

    Google Scholar 

  5. Goodfellow JW, O'Connor JJ (1982) The Oxford knee: a clinical trial. Presented at the Combined Meeting of the Orthopaedic Associations of the English-Speaking World, Capetown

  6. Goss TP, Stinchfied FE, Cosgriff SW (1979) The efficacy of low-dose heparin-warfarin anticoagulation prophylaxis after total hip replacement arthroplasty. Clin Orthop 141:134

    Google Scholar 

  7. Hood RW, Wright TM, Burnstein AH (1982) Retrieval analysis of 210 total knee prostheses. Presented at the 49th Annual Meeting of the American Academy of Orthopaedic Surgeons, New Orleans

  8. Insall JN (1982) Infection in total knee arthroplasty. Instr Course Lect 31:42

    Google Scholar 

  9. Insall JN, Dethmers DA (1982) Revision of total knee arthroplasty. Clin Orthop 170:123

    Google Scholar 

  10. Insall JN, Scott WN, Ranawat CS (1979) The total condylar knee prosthesis. J Bone Joint Surg [Am] 61:173

    Google Scholar 

  11. Mirra JM, Marder RA, Amstutz HC (1982) The pathology of failed total joint arthroplasty. Clin Orthop 170:175

    Google Scholar 

  12. Murase K, Crowninshield RD, Pederson DR, Chang TS (1983) An analysis of tibial component design in total knee arthroplasty. J Biomech 16:13

    Google Scholar 

  13. Pappas MJ (1979) In vitro testing of New Jersey knee replacement system and incongruent knee prosthesis using the New Jersey knee simulator. Biomed Engineering Corp. Report, Appendix 1: Stress calculations, January

  14. Rose RM, Ries MD, Paul IL, Crugnola AN, Ellis E (1982) Wear of the tibial component of the total knee prosthesis. Presented at the 28th Annual Meeting of the Orthopaedic Research Society, New Orleans

  15. Walker PS, Greene D, Reilly D, Thatcher J, Ben-Dov M, Ewald FC (1981) Fixation of tibial components of knee prostheses. J Bone Joint Surg [Am] 63:258

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Buechel, F.F., Pappas, M.J. The New Jersey low-contact-stress knee replacement system: Biomechanical rationale and review of the first 123 cemented cases. Arch. Orth. Traum. Surg. 105, 197–204 (1986). https://doi.org/10.1007/BF00435480

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00435480

Keywords

Navigation