Summary
A mobile-bearing element, metal-backed, interchangeable knee replacement system has been designed to combine low constraint forces with low contact stresses (LCS), allowing nearly normal joint articulation and loading as well as long-term wear resistance of the implants. The system is versatile, including a large number of component options in variable sizes, and it may be used in both primary and revision arthroplasties. The overall results in the first 123 cemented cases (97 patients) with 2- to 7-year follow-up (average 3.7 years) were good to excellent in 88.6%, fair in 3.3%, and poor in 8.1%. Fair and poor results were seen predominantly in multiply operated and implant revision cases. The best results were noted in primary cases, 97.4% of which had good to excellent results. There have been no mechanical implant failures and no meniscal bearing dislocations in this series. Pain relief and restoration of function have been very gratifying with this system.
Similar content being viewed by others
References
Bourne RB, Goodfellow JW, O'Connor JJ (1978) A functional analysis of various knee arthroplasties. Presented at the 24th Annual Meeting of the Orthopaedic Research Society, Dallas
Buechel FF (1982) A simplified evaluation system for the rating of knee function. Orthop Rev 11:97
Cameron HU, Hunter GA (1982) Failure in total knee arthroplasty: mechanisms, revisions, and results. Clin Orthop 170:141
Glynn MK, Sheehan JM (1983) An analysis of the causes of deep infection after hip and knee arthroplasties. Clin Orthop 178:202
Goodfellow JW, O'Connor JJ (1982) The Oxford knee: a clinical trial. Presented at the Combined Meeting of the Orthopaedic Associations of the English-Speaking World, Capetown
Goss TP, Stinchfied FE, Cosgriff SW (1979) The efficacy of low-dose heparin-warfarin anticoagulation prophylaxis after total hip replacement arthroplasty. Clin Orthop 141:134
Hood RW, Wright TM, Burnstein AH (1982) Retrieval analysis of 210 total knee prostheses. Presented at the 49th Annual Meeting of the American Academy of Orthopaedic Surgeons, New Orleans
Insall JN (1982) Infection in total knee arthroplasty. Instr Course Lect 31:42
Insall JN, Dethmers DA (1982) Revision of total knee arthroplasty. Clin Orthop 170:123
Insall JN, Scott WN, Ranawat CS (1979) The total condylar knee prosthesis. J Bone Joint Surg [Am] 61:173
Mirra JM, Marder RA, Amstutz HC (1982) The pathology of failed total joint arthroplasty. Clin Orthop 170:175
Murase K, Crowninshield RD, Pederson DR, Chang TS (1983) An analysis of tibial component design in total knee arthroplasty. J Biomech 16:13
Pappas MJ (1979) In vitro testing of New Jersey knee replacement system and incongruent knee prosthesis using the New Jersey knee simulator. Biomed Engineering Corp. Report, Appendix 1: Stress calculations, January
Rose RM, Ries MD, Paul IL, Crugnola AN, Ellis E (1982) Wear of the tibial component of the total knee prosthesis. Presented at the 28th Annual Meeting of the Orthopaedic Research Society, New Orleans
Walker PS, Greene D, Reilly D, Thatcher J, Ben-Dov M, Ewald FC (1981) Fixation of tibial components of knee prostheses. J Bone Joint Surg [Am] 63:258
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Buechel, F.F., Pappas, M.J. The New Jersey low-contact-stress knee replacement system: Biomechanical rationale and review of the first 123 cemented cases. Arch. Orth. Traum. Surg. 105, 197–204 (1986). https://doi.org/10.1007/BF00435480
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00435480