Skip to main content
Top
Gepubliceerd in: Netherlands Heart Journal 3/2009

01-03-2009 | original article

Infection after ICD implantation: operating room versus cardiac catheterisation laboratory

Auteurs: H. H. F. Remmelts, M. Meine, P. Loh, R. N. W. Hauer, P. A. Doevendans, L. A. van Herwerden, T. E. M. Hopmans, P. M. Ellerbroek

Gepubliceerd in: Netherlands Heart Journal | Uitgave 3/2009

Log in om toegang te krijgen
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Abstract

Background/ObjectivesSince the insertion of an implantable cardioverter-defibrillator (ICD) has become technically comparable to pacemaker implantation, these procedures are increasingly being performed in a cardiac catheterisation laboratory (CCL) instead of the operating room (OR). This study aims to describe the relationship between incidence of ICD infection and procedure setting and to describe the characteristics of ICD infection.
MethodsA retrospective study was performed of first ICD implantation in 677 patients admitted to our hospital between 1996 and 2006. Implantations were performed in the OR until 2003, after 2003 they were carried out in the CCL. The follow-up was censored at one year after implantation. ICD infections were defined as pocket infection or ICD-related endocarditis and a descriptive analysis was performed.
ResultsCardiothoracic surgeons implanted 366 ICDs in the OR Electrophysiologists performed 301 implantations in the CCL. Pulse generators were inserted using a pectoral approach with transvenous lead systems. We identified seven ICD infections (incidence rate 1.2/100 person-years), three of which had been implanted in the OR and four in the CCL.
ConclusionIn this single-centre study no difference in the incidence of ICD infection was observed between implantation in OR and CCL. However, a larger study will be necessary to rule out a relationship with certainty. (Neth Heart J 2009;17:95–100.)
Literatuur
1.
go back to reference Dimarco JP. Implantable cardioverter-defibrillators. N Engl J Med 2003;349:1836–47. Dimarco JP. Implantable cardioverter-defibrillators. N Engl J Med 2003;349:1836–47.
2.
go back to reference Gil P, Fernandez Guerrero ML, Bayona JF, Rubio JM, de Górgolas M, Granizo JJ, et al. Infections of implantable cardioverter-defibrillators: frequency, predisposing factors and clinical significance. Clin Microbiol Infect 2006;12:533–7. Gil P, Fernandez Guerrero ML, Bayona JF, Rubio JM, de Górgolas M, Granizo JJ, et al. Infections of implantable cardioverter-defibrillators: frequency, predisposing factors and clinical significance. Clin Microbiol Infect 2006;12:533–7.
3.
go back to reference Horan TC, Gaynes RP, Martone WJ, Jarvis WR, Emori TG. CDC definitions of nosocomial surgical site infections, 1992: a modification of CDC definitions of surgical wound infections. Infect Control Hosp Epidemiol 1992;13:606–8. Horan TC, Gaynes RP, Martone WJ, Jarvis WR, Emori TG. CDC definitions of nosocomial surgical site infections, 1992: a modification of CDC definitions of surgical wound infections. Infect Control Hosp Epidemiol 1992;13:606–8.
4.
go back to reference Durack DT, Lukes AS, Bright DK. New criteria for diagnosis of infective endocarditis: utilization of specific echocardiographic findings. Duke Endocarditis Service. Am J Med 1994;96:200–9. Durack DT, Lukes AS, Bright DK. New criteria for diagnosis of infective endocarditis: utilization of specific echocardiographic findings. Duke Endocarditis Service. Am J Med 1994;96:200–9.
5.
go back to reference Garner JS, Jarvis WR, Emori TG, Horan TC, Hughes JM. CDC definitions for nosocomial infections, 1988. Am J Infect Control 1988;16:128–40. Garner JS, Jarvis WR, Emori TG, Horan TC, Hughes JM. CDC definitions for nosocomial infections, 1988. Am J Infect Control 1988;16:128–40.
6.
go back to reference Zipes DP, Camm AJ, Borggrefe M, Buxton AE, Chaitman B, Fromer M, et al. ACC/AHA/ESC 2006 Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: a report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (writing committee to develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Circulation 2006;114:e385–e484. Zipes DP, Camm AJ, Borggrefe M, Buxton AE, Chaitman B, Fromer M, et al. ACC/AHA/ESC 2006 Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: a report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (writing committee to develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death): developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society. Circulation 2006;114:e385–e484.
7.
go back to reference Lai KK, Fontecchio SA. Infections associated with implantable cardioverter defibrillators placed transvenously and via thoracotomies: epidemiology, infection control, and management. Clin Infect Dis 1998;27:265–9. Lai KK, Fontecchio SA. Infections associated with implantable cardioverter defibrillators placed transvenously and via thoracotomies: epidemiology, infection control, and management. Clin Infect Dis 1998;27:265–9.
8.
go back to reference Trappe HJ, Pfitzner P, Klein H, Wenzlaff P. Infections after cardioverter-defibrillator implantation: observations in 335 patients over 10 years. Br Heart J 1995;73:20–4. Trappe HJ, Pfitzner P, Klein H, Wenzlaff P. Infections after cardioverter-defibrillator implantation: observations in 335 patients over 10 years. Br Heart J 1995;73:20–4.
9.
go back to reference Mela T, McGovern BA, Garan H, Vlahakes GJ, Torchiana DF, Ruskin J, et al. Long-term infection rates associated with the pectoral versus abdominal approach to cardioverter-defibrillator implants. Am J Cardiol 2001;88:750–3. Mela T, McGovern BA, Garan H, Vlahakes GJ, Torchiana DF, Ruskin J, et al. Long-term infection rates associated with the pectoral versus abdominal approach to cardioverter-defibrillator implants. Am J Cardiol 2001;88:750–3.
10.
go back to reference Gandelman G, Frishman WH, Wiese C, Green-Gastwirth V, Hong S, Aronow WS, et al. Intravascular device infections: epidemiology, diagnosis, and management. Cardiol Rev 2007;15:13–23. Gandelman G, Frishman WH, Wiese C, Green-Gastwirth V, Hong S, Aronow WS, et al. Intravascular device infections: epidemiology, diagnosis, and management. Cardiol Rev 2007;15:13–23.
11.
go back to reference Chua JD, Wilkoff BL, Lee I, Juratli N, Longworth DL, Gordon SM. Diagnosis and management of infections involving implantable electrophysiologic cardiac devices. Ann Intern Med 2000;133:604–8. Chua JD, Wilkoff BL, Lee I, Juratli N, Longworth DL, Gordon SM. Diagnosis and management of infections involving implantable electrophysiologic cardiac devices. Ann Intern Med 2000;133:604–8.
12.
go back to reference Sohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, et al. Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections. J Am Coll Cardiol2007;49:1851–9. Sohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, et al. Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections. J Am Coll Cardiol2007;49:1851–9.
13.
go back to reference Uslan DZ, Sohail MR, St Sauver JL, Friedman PA, Hayes DL, Stoner SM, et al. Permanent pacemaker and implantable cardioverter defibrillator infection: a population-based study. Arch Intern Med 2007;167:669–75. Uslan DZ, Sohail MR, St Sauver JL, Friedman PA, Hayes DL, Stoner SM, et al. Permanent pacemaker and implantable cardioverter defibrillator infection: a population-based study. Arch Intern Med 2007;167:669–75.
Metagegevens
Titel
Infection after ICD implantation: operating room versus cardiac catheterisation laboratory
Auteurs
H. H. F. Remmelts
M. Meine
P. Loh
R. N. W. Hauer
P. A. Doevendans
L. A. van Herwerden
T. E. M. Hopmans
P. M. Ellerbroek
Publicatiedatum
01-03-2009
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 3/2009
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/BF03086226

Andere artikelen Uitgave 3/2009

Netherlands Heart Journal 3/2009 Naar de uitgave