Fifty years of cardiac pacing: the dark side of the moon?

Auteur: C. C. de Cock

Gepubliceerd in: Netherlands Heart Journal | Uitgave 1/2008

Log in om toegang te krijgen
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Abstract

Fifty years after its introduction, cardiac pacing has evolved from an experimental medical treatment to an expanding field in today's cardiology. Only recently there is accumulating evidence that prolonged stimulation of the right ventricular apex is associated with clinically significant adverse effects. In this commentary, the potential adverse effects are summarised and potential modifications in contemporary pacing are discussed. (Neth Heart J 2008;16(suppl 1):S12-S14.)
Literatuur
1.
go back to reference Report of the World Health Organization (WHO): World health statistics 2008. ISBN 978 92 4 156359 8 (NLM classification: WA 900.1). Report of the World Health Organization (WHO): World health statistics 2008. ISBN 978 92 4 156359 8 (NLM classification: WA 900.1).
2.
go back to reference Maisel W, Moynahan M, Zuckerman B, Gross T, Tovar O, Tillmann D, et al. Pacemaker and ICD generator malfunctions. Analysis of Food and Drug Administration annual report. JAMA 2006;295:1901-6. Maisel W, Moynahan M, Zuckerman B, Gross T, Tovar O, Tillmann D, et al. Pacemaker and ICD generator malfunctions. Analysis of Food and Drug Administration annual report. JAMA 2006;295:1901-6.
3.
go back to reference Wiggers CJ. The muscular reactions of the mammalian ventricles to artificial surface stimuli. Am J Physiol 1925;37C:275-82. Wiggers CJ. The muscular reactions of the mammalian ventricles to artificial surface stimuli. Am J Physiol 1925;37C:275-82.
4.
go back to reference Tse HF, Lau CP. Long-term effect of right ventricular pacing on myocardial perfusion and function. J Am Coll Cardiol 1997;29: 744-9. Tse HF, Lau CP. Long-term effect of right ventricular pacing on myocardial perfusion and function. J Am Coll Cardiol 1997;29: 744-9.
5.
go back to reference Tantengco MV,Thomas RL, Karpawich PP. Left ventricular dysfunction after long-term right ventricular apical pacing in the young, J Am Coll Cardiol 2001;37:2093-100. Tantengco MV,Thomas RL, Karpawich PP. Left ventricular dysfunction after long-term right ventricular apical pacing in the young, J Am Coll Cardiol 2001;37:2093-100.
6.
go back to reference Connolly SJ, Kerr CR, Gent M, Roberts R, Yusuf S, Gillis AM, et al. Canadian Trial of Physiologic Pacing Investigators, Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. N Engl J Med 2000;342:1385-91. Connolly SJ, Kerr CR, Gent M, Roberts R, Yusuf S, Gillis AM, et al. Canadian Trial of Physiologic Pacing Investigators, Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. N Engl J Med 2000;342:1385-91.
7.
go back to reference Lamas GA, Lee KL, Sweeney MO, Silverman R, Leon A, Yee R, et al. Ventricular pacing or dual-chamber pacing for sinus-node dysfunction. N Engl J Med 2002;346:1854-62. Lamas GA, Lee KL, Sweeney MO, Silverman R, Leon A, Yee R, et al. Ventricular pacing or dual-chamber pacing for sinus-node dysfunction. N Engl J Med 2002;346:1854-62.
8.
go back to reference Sweeney MO, Hellkamp AS, Ellenbogen KE, Greenspon AJ, Freedman RA, Lee KL, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 2003;107:2932-7. Sweeney MO, Hellkamp AS, Ellenbogen KE, Greenspon AJ, Freedman RA, Lee KL, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation 2003;107:2932-7.
9.
go back to reference The DAVID Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantble defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA 2002;288:3115-23. The DAVID Trial Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantble defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA 2002;288:3115-23.
10.
go back to reference Steinberg JS, Fischer A, Wang P, Schuger C, Daubert C, McNitt S, et al. The clinical implications of cumulative ventricular pacing in the Multicenter Automatic Defibrillator Trial (MADIT II). J Cardiovasc Electrophysiol 2005;16:359-65. Steinberg JS, Fischer A, Wang P, Schuger C, Daubert C, McNitt S, et al. The clinical implications of cumulative ventricular pacing in the Multicenter Automatic Defibrillator Trial (MADIT II). J Cardiovasc Electrophysiol 2005;16:359-65.
11.
go back to reference Nielsen JC, Pedersen AK, Mortensen PT, Pedersen OL, Pedersen AK, et al. Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome. Europace 1999;1:113-20. Nielsen JC, Pedersen AK, Mortensen PT, Pedersen OL, Pedersen AK, et al. Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome. Europace 1999;1:113-20.
12.
go back to reference Sweeney MO, Shea JB, Fox V. Randomized trial of a new atrial-based minimal ventricular pacing mode in dual chamber implantable cardioverter-defibrillators: MVP. Heart Rhythm 2004;1:60-7. Sweeney MO, Shea JB, Fox V. Randomized trial of a new atrial-based minimal ventricular pacing mode in dual chamber implantable cardioverter-defibrillators: MVP. Heart Rhythm 2004;1:60-7.
13.
go back to reference Sweeney MO, Bank AJ, Nsah E. Koullick M, Zeng QC, Hettrick D, et al. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. N Engl J Med 2007;357:1000-8. Sweeney MO, Bank AJ, Nsah E. Koullick M, Zeng QC, Hettrick D, et al. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. N Engl J Med 2007;357:1000-8.
14.
go back to reference Deshmukh P, Casavant DA, Romanyshyn M, Anderson K. Permanent, direct His-bundle pacing, a novel approach to cardiac pacing in patients with normal His-Purkinje activation. Circulation 2000;101:869-77. Deshmukh P, Casavant DA, Romanyshyn M, Anderson K. Permanent, direct His-bundle pacing, a novel approach to cardiac pacing in patients with normal His-Purkinje activation. Circulation 2000;101:869-77.
15.
go back to reference de Cock CC, Giudici MC, Twisk JW. Comparison of the haemo-dynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing. Europace 2003;5:275-8. de Cock CC, Giudici MC, Twisk JW. Comparison of the haemo-dynamic effects of right ventricular outflow-tract pacing with right ventricular apex pacing. Europace 2003;5:275-8.
16.
go back to reference Giudici MC, Karpawich PP. Alternative pacing sites: it's time to define terms. Pacing Clin Cardiol 1999;22:551-3. Giudici MC, Karpawich PP. Alternative pacing sites: it's time to define terms. Pacing Clin Cardiol 1999;22:551-3.
17.
go back to reference Lieberman R, Padeletti L, Schreuderr J, Jackson K. Michelucci A, Colella A, et al. Ventricular pacing lead position alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction. J Am Coll Cardiol 2006;48:1634-41. Lieberman R, Padeletti L, Schreuderr J, Jackson K. Michelucci A, Colella A, et al. Ventricular pacing lead position alters systemic hemodynamics and left ventricular function in patients with and without reduced ejection fraction. J Am Coll Cardiol 2006;48:1634-41.
18.
go back to reference Varma C, O'Callaghan P, Mahon NG, Hnatkova K, McKenna W, Camm AJ, et al. Effects of multisite pacing on ventricular coordination. Heart 2002;87:322-8. Varma C, O'Callaghan P, Mahon NG, Hnatkova K, McKenna W, Camm AJ, et al. Effects of multisite pacing on ventricular coordination. Heart 2002;87:322-8.
Metagegevens
Titel
Fifty years of cardiac pacing: the dark side of the moon?
Auteur
C. C. de Cock
Publicatiedatum
01-01-2008
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 1/2008
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/BF03086198

Andere artikelen Uitgave 1/2008

Netherlands Heart Journal 1/2008 Naar de uitgave