Skip to main content
Top
Gepubliceerd in: Perspectives on Medical Education 3/2021

Open Access 28-09-2020 | Show and Tell

Development of a 3D printed simulator for closed reduction of distal radius fractures

Auteurs: William Dixon, Nathaniel Miller, Georgia G. Toal, Stefanie S. Sebok-Syer, Michael A. Gisondi

Gepubliceerd in: Perspectives on Medical Education | Uitgave 3/2021

share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
insite
ZOEKEN

Abstract

Background

The use of simulators in medical education is critical for developing procedural competence prior to treating patients. Current training of emergency physicians to perform distal radius fracture reduction is inconsistent and inadequate.

Approach

We developed a 3D printed distal radius fracture simulation training model that is easy to assemble and relatively inexpensive. We present step-by-step instructions to reproduce the model.

Evaluation

The model was found to have high fidelity for training by both instructors and participants in a simulation-based mastery learning course.

Reflection

We successfully designed a low cost, easy to reproduce, high fidelity model for use in a simulation-based mastery learning course to teach distal radius fracture reduction.
Opmerkingen

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1007/​s40037-020-00609-w) contains supplementary material, which is available to authorized users.

Background

The successful reduction and treatment of distal radius fractures in the emergency department is a core competency for emergency physicians. However, there are widely variable opportunities to master this skill during emergency medicine residency training in the United States. Subsequently, emergency physicians may lack the necessary expertise to teach the next generation of trainees to perform this procedure competently, leading to difficulties in standardizing training experience across the profession and perpetuating this lack of skill development in the specialty. The current approach to teaching fracture reduction can be irregular; typically, the procedure is taught at the bedside and can be limited by supervisor experience and comfort with the procedure [1]. Existing research shows both dissatisfaction with musculoskeletal training and deficiencies in musculoskeletal knowledge amongst some emergency physicians [2].
Simulation-based mastery learning improves training in bedside procedures and can serve as a theoretical framework to address training gaps [36]. Briefly, simulation-based mastery learning stresses asynchronous preparation, deliberate practice, close supervision during training, and a checklist assessment to ensure learning to a predetermined mastery standard. Simulation offers learners opportunities for deliberate practice of a procedure supervised by skilled educators, before performing these procedures in the actual clinical environment. Simulators for distal radius fractures are described in the orthopedic literature; however, reproducing these models requires the purchase of expensive, industrially produced replica bones [79]. The advent of at-home 3D printing provides the opportunity for a more generally reproducible model that can potentially increase access to simulation-based educational sessions on a wider scale.
Given the need for inexpensive, reproducible, and portable models for simulation of common procedures, this paper describes the production of a high-fidelity distal radius fracture model to teach proper reduction techniques in a simulation-based mastery learning course. Another advantage of our simulator is that it can be used to concurrently teach the hematoma block procedure, where a small amount of anesthetic is injected into the area around the fracture to decrease pain associated with the reduction. The focus of this paper is on the construction of the model, though brief course outcomes and trainee responses to use of the simulator are included to illustrate context.

Approach

To build our distal radius fracture model, we obtained an anatomically correct radius and ulna model from the 3D printing open source site ThingiverseⓇ (www.​thingiverse.​com, Mountain View, CA, USA) and subsequently uploaded this file into a 3D printing editing website TinkerCad Ⓡ (www.​tinkercad.​com, San Rafael, CA, USA). Using the editing software, we created a fracture line through the distal radius to model a distal radius fracture. The fracture pieces can be found on TinkerCad under User ID “wdixonPC6LL” as an openly shared file (Fig. 1a). Multiple anchor points through both pieces of the fracture were tested in the model to allow for a dynamic connection between the pieces; these points were optimized for tension and displacement. The bones were printed using an XYZ DaVinci Pro 3D printer (XYZ Printing, San Diego, CA, USA) with ABS filament, though could be printed from any 3D printer with a large enough print bed (Fig. 1b). We found that including a support brim and utilizing the “slow print speed for small parts” setting increased stability of the printed model; additional settings are found in Appendix 1 of the Electronic Supplementary Material. The radius fragments were connected using rubber O‑ring material through the premade dorsal aspect anchor points and secured with zip-ties to create a resistance force to the reduction (Fig. 1c, d).
The bones were then secured on the volar aspect with an inflexible string; we recommend fishing line or a single filament string with good tensile strength to create a point of maximum displacement of the bone fragments (Fig. 1e, f). We secured the radius and ulna at the distal end with a hinge (1.5 inch or 3.81 cm) screwed into pre-made screw holes (Fig. 1g). The attached bones were set in a custom 3D mold (also found on TinkerCad under the same user identification as above) that can be filled with gelatin or medical simulation gel to simulate the soft tissues of the arm (Fig. 1h). We found the medical simulation gel to be more durable, reusable, and clean; this will likely decrease costs over time and allows for longer term storage. After the gel is set, a section of the gel can be peeled off the dorsal aspect so the bone can be palpated under the skin and to allow for fracture articulation. The hinged pieces are subsequently attached to a block of wood (dimensions: 3.5 × 3 × 0.75 inches, or 8.89 × 7.62 × 1.9 cm), which replicates the hand (Fig. 1i). This attachment allows the hand to be placed under traction to assist with a realistic reduction. The entire model is placed into a rubber intravenous catheter training arm (Anatomy Warehouse, Evanston, IL, USA) to obscure details of the fracture model and to simulate a closed reduction performed at the bedside (Fig. 1i). Excluding the cost of the 3D printer, the total cost of the model was approximately USD $140; this includes some items that are used for multiple models, and the most expensive parts are reusable. See Appendix 2 of the Electronic Supplementary Material for a complete list of costs and examples of each piece of the model.

Evaluation

We examined the fidelity of the distal radius fracture model as part of a simulation-based mastery learning curriculum. The Stanford University Institutional Review Board approved this study. The mastery standard was defined as the minimum passing score for the course, as determined by an expert panel using the Mastery Angoff approach [10]; the minimum passing score was 90% of the total 41 checklist items. We trained all first-year emergency medicine residents (n = 15) and first-year orthopedic surgery residents (n = 7) at our institution to perform a distal radius fracture reduction using our model and checklist, at the beginning of their residency. First-year trainees are novices and none of our participants had prior formal training in this procedure, which is typical when entering residency. All participants achieved the minimum passing score at the end of our course. Instructors included emergency medicine attendings and orthopedic surgery chief residents.
Course participants and instructors were surveyed regarding the fidelity of the model. The survey tool was created by the author team, reviewed and edited by members of the expert panel who participated in the standard setting exercise, and was piloted in this study. The tool included statements regarding fidelity of the model and confidence in future performance of the procedure, using a Likert-style scale of Strongly Agree to Strongly Disagree [Appendix 3 of the Electronic Supplementary Material]. The majority of participants strongly agreed or agreed that the model had high fidelity (86%, n = 22) and that its use in a simulation-based mastery learning course prepared them to treat patients with distal radius fractures (91%, n = 22). Each experienced instructor (n = 4, excluding author WD) agreed or strongly agreed that the model realistically simulates the reduction of a displaced distal radius fracture and that it is useful in teaching the procedure, although feedback suggested we improve the tactile feel of the model for examination. Responses from instructors were also mixed on the fidelity of the model for the purpose of hematoma blocks, which we plan to address in future models. One advantage of the simulation skin that we used is that it hides needle tracks, requiring students to palpate the model for an accurate hematoma block, instead of following prior insertion points. Our team plans to trial other options for skin and hematoma blocks in second-generation models.

Reflection

Reduction of a distal radius fracture is a common bedside procedure in the emergency department and there is a clearly demonstrated need to improve competence for this procedure among emergency physicians in the United States. We successfully addressed this problem by developing a novel 3D printed distal radius fracture model to facilitate instruction in reduction techniques using simulation-based mastery learning. Our model is an effective simulator with positive assessments of fidelity for use in training by both residents and faculty members. While 3D printers can be costly to purchase, the separate printing material is not expensive; many universities offer access to 3D printers for teaching purposes, such as the one we described.
The experience of creating a 3D printed distal radius fracture model allowed for professional collaboration and enthusiasm among a diverse group of team members. Our team received positive feedback from emergency medicine and orthopedic surgery residents who applied the knowledge and skills learned in the mastery learning course at the bedside soon thereafter, and residents continue to proudly share accounts of successful fracture reductions.
Challenges encountered in this project centered around early testing and optimization of the model. We will continue to refine our simulator as new options for more flexible skin become commercially available; for example, a negative mold with poured silicone skin [11]. Next-generation versions of our model will include the placement of a catheter through the hollow lumen of the bone to insert moulage blood, to better replicate a hematoma block. Limitations of this project include fidelity testing at a single site and no assessment of patient- level translational outcomes. Next-generation versions of our model and training curriculum will be assessed for patient-level outcomes and we hope to include multiple academic sites.
Our models are now available in an in situ simulation room in our emergency department for just-in-time learning and practice prior to performing the procedure at the bedside. Our team continues to develop a suite of new, realistic simulators for teaching other common orthopedic procedures.

Acknowledgements

We thank the Stanford Teaching and Mentoring Academy Innovation Grants program for their support and funding of this project.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail
Literatuur
1.
go back to reference Tran V, Cobbett J, Brichko L. Procedural competency in emergency medicine. Emerg Med Australasia. 2018;30:103–6.CrossRef Tran V, Cobbett J, Brichko L. Procedural competency in emergency medicine. Emerg Med Australasia. 2018;30:103–6.CrossRef
2.
go back to reference Comer G, Liang E, Bishop J. Lack of proficiency in musculoskeletal medicine among emergency medicine physicians. J Orthop Trauma. 2014;28(4):e85–e7.CrossRef Comer G, Liang E, Bishop J. Lack of proficiency in musculoskeletal medicine among emergency medicine physicians. J Orthop Trauma. 2014;28(4):e85–e7.CrossRef
3.
go back to reference McGaghie WC, Issenberg SB, Barsuk JH, Wayne DB. A critical review of simulation-based mastery learning with translational outcomes. Med Educ. 2014;48(4):375–85.CrossRef McGaghie WC, Issenberg SB, Barsuk JH, Wayne DB. A critical review of simulation-based mastery learning with translational outcomes. Med Educ. 2014;48(4):375–85.CrossRef
4.
go back to reference Barsuk JH, McGaghie WC, Cohen ER, Balachandran JS, Wayne DB. Use of simulation-based mastery learning to improve the quality of central venous catheter placement in a medical intensive care unit. J Hosp Med. 2009;4(7):397–403.CrossRef Barsuk JH, McGaghie WC, Cohen ER, Balachandran JS, Wayne DB. Use of simulation-based mastery learning to improve the quality of central venous catheter placement in a medical intensive care unit. J Hosp Med. 2009;4(7):397–403.CrossRef
5.
go back to reference Barsuk JH, Cohen ER, Vozenilek JA, O’Connor LM, McGaghie WC, Wayne DB. Simulation-based education with mastery learning improves paracentesis skills. J Grad Med Educ. 2012;4(1):23–7.CrossRef Barsuk JH, Cohen ER, Vozenilek JA, O’Connor LM, McGaghie WC, Wayne DB. Simulation-based education with mastery learning improves paracentesis skills. J Grad Med Educ. 2012;4(1):23–7.CrossRef
6.
go back to reference Wayne DB, Barsuk JH, O’Leary KJ, Fudala MJ, McGaghie WC. Mastery learning of thoracentesis skills by internal medicine residents using simulation technology and deliberate practice. J Hosp Med. 2008;3(1):48–54.CrossRef Wayne DB, Barsuk JH, O’Leary KJ, Fudala MJ, McGaghie WC. Mastery learning of thoracentesis skills by internal medicine residents using simulation technology and deliberate practice. J Hosp Med. 2008;3(1):48–54.CrossRef
7.
go back to reference Egan C, Egan R, Curran P, Bryan K, Fleming P. Development of a model for teaching manipulation of a distal radius fracture. J Bone Joint Surg. 2013;95(5):433–8.CrossRef Egan C, Egan R, Curran P, Bryan K, Fleming P. Development of a model for teaching manipulation of a distal radius fracture. J Bone Joint Surg. 2013;95(5):433–8.CrossRef
8.
go back to reference Mayne I, Brydges R, Moktar J, Murnaghan M. Development and assessment of a distal radial fracture model as a clinical teaching tool. J Bone Joint Surg. 2016;98(5):410–6.CrossRef Mayne I, Brydges R, Moktar J, Murnaghan M. Development and assessment of a distal radial fracture model as a clinical teaching tool. J Bone Joint Surg. 2016;98(5):410–6.CrossRef
9.
go back to reference Seeley M, Fabricant P, Lawrence J. Teaching the basics: development and validation of a distal radius reduction and casting model. Clin Orthop Relat Res. 2017;475(9):2298–305.CrossRef Seeley M, Fabricant P, Lawrence J. Teaching the basics: development and validation of a distal radius reduction and casting model. Clin Orthop Relat Res. 2017;475(9):2298–305.CrossRef
10.
go back to reference Yudkowsky R, Park YS, Lineberry M, Knox A, Ritter EM. Setting mastery learning standards. Acad Med. 2015;90(11):1495–500.CrossRef Yudkowsky R, Park YS, Lineberry M, Knox A, Ritter EM. Setting mastery learning standards. Acad Med. 2015;90(11):1495–500.CrossRef
11.
go back to reference Powell AR, Srinivasan S, Green G, Kim J, Zopf DA. Computer-Aided design, 3‑D-printed manufacturing, and expert validation of a high-fidelity facial flap surgical simulator. JAMA Facial Plast Surg. 2019;21(4):327–31.CrossRef Powell AR, Srinivasan S, Green G, Kim J, Zopf DA. Computer-Aided design, 3‑D-printed manufacturing, and expert validation of a high-fidelity facial flap surgical simulator. JAMA Facial Plast Surg. 2019;21(4):327–31.CrossRef
Metagegevens
Titel
Development of a 3D printed simulator for closed reduction of distal radius fractures
Auteurs
William Dixon
Nathaniel Miller
Georgia G. Toal
Stefanie S. Sebok-Syer
Michael A. Gisondi
Publicatiedatum
28-09-2020
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Perspectives on Medical Education / Uitgave 3/2021
Print ISSN: 2212-2761
Elektronisch ISSN: 2212-277X
DOI
https://doi.org/10.1007/s40037-020-00609-w

Andere artikelen Uitgave 3/2021

Perspectives on Medical Education 3/2021 Naar de uitgave