Skip to main content
Top
Gepubliceerd in: Netherlands Heart Journal 4/2007

01-04-2007 | original article

Clinical implementation of guidelines for cardioverter defibrillator implantation: lost in translation?

Auteurs: C. J. W. Borleffs, A. A. M. Wilde, E. Wever, A. Mosterd

Gepubliceerd in: Netherlands Heart Journal | Uitgave 4/2007

Log in om toegang te krijgen
share
DELEN

Deel dit onderdeel of sectie (kopieer de link)

  • Optie A:
    Klik op de rechtermuisknop op de link en selecteer de optie “linkadres kopiëren”
  • Optie B:
    Deel de link per e-mail

Abstract

Purpose: Guidelines for implantation of cardioverter defibrillators (ICD) are increasingly including indications for primary prevention of sudden cardiac death in high-risk groups, where ICDs were traditionally implanted for secondary prevention. We performed a single-centre audit to evaluate adherence to the recent Dutch guidelines.
Methods: All 1886 patients visiting a large regional Dutch teaching hospital (attending 1.8 to 2.0% of the Dutch population) in November 2005 were screened using the recently updated Dutch guidelines. Patients fulfilling these criteria were categorised as having an ICD indication for primary or secondary prevention.
Results: 135 patients had an indication for ICD, 19 of whom had one or received one. Of the remaining 116 patients, 14 were ‘new’ to the department of cardiology. The 102 ‘known’ patients had 466 doctor-patient contacts in the previous year, which averages 4.57 cardiology contacts per patient per year. Patients were more likely to receive an ICD for the secondary prevention of SCD (10/11, 91%) than for primary prevention (9/124, 7%).
Conclusion: In a large regional teaching hospital in the Netherlands, only a small proportion of patients eligible for ICD implantation actually receive one. Cardiologists tend to implant ICDs for secondary prevention of SCD. The low ICD implantation rate for primary prevention of SCD may relate to logistics (e.g. permission to implant ICDs, the presence of an electrophysiology lab) or the perceived low cost-benefit ratio. Our results indicate that once the substantial backlog (13,500 ICDs) has been addressed, the annual implantation of new ICDs should rise from the current 125 to at least 510 per million inhabitants per year in the Netherlands. (Neth Heart J 2007;15:129-32.)
Literatuur
go back to reference Priori SG, Aliot E, Blomstrom-Lundqvist C, Bossaert L, Breithardt G, Brugada P, et al. Task Force on Sudden Cardiac Death of the European Society of Cardiology. Eur Heart J 2001;22:1374-1450. Priori SG, Aliot E, Blomstrom-Lundqvist C, Bossaert L, Breithardt G, Brugada P, et al. Task Force on Sudden Cardiac Death of the European Society of Cardiology. Eur Heart J 2001;22:1374-1450.
go back to reference Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, et al. Improved survival with an implanted defibrillator in patients with coronary disease at risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. New Engl J Med 1996;335:1933-940. Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, et al. Improved survival with an implanted defibrillator in patients with coronary disease at risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. New Engl J Med 1996;335:1933-940.
go back to reference Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. New Engl J Med 2002;346:877-83. Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Multicenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. New Engl J Med 2002;346:877-83.
go back to reference Priori SG, Aliot E, Blomstrom-Lundqvist C, Bossaert L, Breithardt G, Brugada P, et al. Update of the guidelines on sudden cardiac death of the European Society of Cardiology. Eur Heart J 2003; 24:13-5. Priori SG, Aliot E, Blomstrom-Lundqvist C, Bossaert L, Breithardt G, Brugada P, et al. Update of the guidelines on sudden cardiac death of the European Society of Cardiology. Eur Heart J 2003; 24:13-5.
go back to reference Cunningham AD, Plummer CJ, McComb JM, Lord SW, Cunningham MW, Toussiant JM, et al. The implantable cardioverter-defibrillator: postcode prescribing in the UK 1998-2002. Heart 2005;91:1280-3. Cunningham AD, Plummer CJ, McComb JM, Lord SW, Cunningham MW, Toussiant JM, et al. The implantable cardioverter-defibrillator: postcode prescribing in the UK 1998-2002. Heart 2005;91:1280-3.
go back to reference Al-Khatib SM, Anstrom KJ, Eisenstein EL, Peterson ED, Jollis JG, Mark DB, et al. Clinical and economic implications of the Multicenter Automatic Defibrillator Implantation Trial-II. Ann Intern Med 2005;142:593-600. Al-Khatib SM, Anstrom KJ, Eisenstein EL, Peterson ED, Jollis JG, Mark DB, et al. Clinical and economic implications of the Multicenter Automatic Defibrillator Implantation Trial-II. Ann Intern Med 2005;142:593-600.
go back to reference van Erven L, van Dessel PFHM, Simmers TA, van Gelder IC, Hauer RNW, Wever EFD, et al. Guidelines ICD implantation 2005 – an update. http://www.cardiologie.nl/2/pagecontent/main_richtlijnen/20060821/icd2005.pdf . van Erven L, van Dessel PFHM, Simmers TA, van Gelder IC, Hauer RNW, Wever EFD, et al. Guidelines ICD implantation 2005 – an update. http://​www.​cardiologie.​nl/​2/​pagecontent/​main_​richtlijnen/​20060821/​icd2005.​pdf .
go back to reference Cleland JG, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, et al. Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators. New Engl J Med 2005;352: 1539-49. Cleland JG, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, et al. Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators. New Engl J Med 2005;352: 1539-49.
go back to reference Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, et al. Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. New Engl J Med 2005;352:225-37. Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, et al. Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. New Engl J Med 2005;352:225-37.
go back to reference Swedberg K, Cleland J, Dargie H, Drexler H, Follath F, Komajda M, et al.; Task Force for the Diagnosis and Treatment of Chronic Heart Failure of the European Society of Cardiology. Guidelines for the diagnosis and treatment of chronic heart failure: executive summery (update 2005): The Task Force for the Diagnosis and Treatment of Chronic Heart Failure of the European Society of Cardiology. Eur Heart J 2005;26:1115-40. Swedberg K, Cleland J, Dargie H, Drexler H, Follath F, Komajda M, et al.; Task Force for the Diagnosis and Treatment of Chronic Heart Failure of the European Society of Cardiology. Guidelines for the diagnosis and treatment of chronic heart failure: executive summery (update 2005): The Task Force for the Diagnosis and Treatment of Chronic Heart Failure of the European Society of Cardiology. Eur Heart J 2005;26:1115-40.
go back to reference Hauser RG. The growing mismatch between patient longevity and the service life of implantable cardioverter-defibrillators. J Am Coll Cardiol 2005;45:2022-5. Hauser RG. The growing mismatch between patient longevity and the service life of implantable cardioverter-defibrillators. J Am Coll Cardiol 2005;45:2022-5.
Metagegevens
Titel
Clinical implementation of guidelines for cardioverter defibrillator implantation: lost in translation?
Auteurs
C. J. W. Borleffs
A. A. M. Wilde
E. Wever
A. Mosterd
Publicatiedatum
01-04-2007
Uitgeverij
Bohn Stafleu van Loghum
Gepubliceerd in
Netherlands Heart Journal / Uitgave 4/2007
Print ISSN: 1568-5888
Elektronisch ISSN: 1876-6250
DOI
https://doi.org/10.1007/BF03085968

Andere artikelen Uitgave 4/2007

Netherlands Heart Journal 4/2007 Naar de uitgave

imaging in cardiology

Crossing coronary arteries