A patient with a cardiac pacemaker is condemned for life to attend a pacemaker clinic for follow-up. One of the main objectives for follow-up is to anticipate impending pacemaker system failure before there is risk to the patient. Battery depletion impairs pacemaker function and is still the main reason for surgical intervention.1 Beginning or actual failure of systems must be ascertained in the clinic and the necessary steps taken to remedy the situation.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Irnich W, Batz L. Schritttmacher-Infektionen aus der Sicht des Zentralregisters Herzschrittmacher. In: Winter UJ, Zegelman M (eds), Herzschrittmacher-und Defibrillator-Infektionen. Stuttgart, Georg Thieme Verlag, 1994, pp 14–9.
Thalen HJ. The Artificial Cardiac Pacemaker. Thesis. Rijksuniversiteit Groningen, 1969, p 331.
Bernstein AD, Irwin ME, Parsonnet V, Wilkoff BL, Black WR, Buckingham TA, Maloney JD, Reynolds DD, Saksena S, Singer I, Nickelson DE, Semiring L. Report of the NASPE Policy Conference on Antibradycardia Pacemaker Follow-Up: Effectiveness, Needs, Resources. PACE 1994;17:1714–29.
Rodrigo FA, Berg JW van den, Thalen HJ, Koops J. Control of patients with implanted pacemakers. Proceedings of the European Congres of Cardiology, September 1968, Serie C, 70:449–55.
Kemp P van der, Schmidt JT, Ruiter R de, Hove JWJ van, Boer TJM de, Schrama T. Pacemakerdata 1993–1994. Oudenhoorn, STIMRO, 1993 (90-71839-03-6).
Lampadius MS. Herzschrittmacher-Typenkartei. Kochel am See, FGS-Forschungsgesselschaft Electrostimulation m.b.H., 1994.
Sedney MI. The implantable cardiac pacemaker. Thesis. Rijksuniversiteit Leiden, 1986.
Anonymous. Reflex Model 8218 physician’s manual. Englewood, Colorado, Telectronics Pacing Systems, 1992.
Sutton R, Bourgeois IM. The Foundations of Cardiac Pacing Pt. I: An illustrated practical guide to basic pacing. Mount Kisco, New York, Futura Publishing Company, 1991.
Levine PA. Holter and pacemaker diagnostics. In: Aubert AE, Ector H, Stroobandt R (eds), Cardiac pacing and Electrophysiology; a bridge to the 21st century. Dordrecht, Kluwer Academic Publishers, 1994, pp 309–24.
Cazeau S, Ritter P, Nitzché R, Limousin M, Mugica J. Diagnosis of atrial arrhytmias Using the holter function of a new DDD pacemaker. PACE 1994;17:2106–13.
Hayes DL, Vlietstra RE. Pacemaker malfunction. (Review). Annals of Internal Medicine 1993;119:828–35.
Levine PA. Differential Diagnosis, evaluation, and management of Pacing System Malfunctioning. In: Ellenbogen KA (ed.), Cardiac Pacing. Boston, Blackwell Scientific Publication, 199, pp 309–82.
Hayes DL. Programmability. In: Furman S, Hayes DL, Holmes DR (eds), A Practice of Cardiac Pacing. Mount Kisco, New York, Futura Publishing Compagny, Inc., 1993, pp 635–63.
Raitt MH, Stelzer KJ, Laramore GE. Runaway pacemaker during high-energy neutron radiation therapy. Chest 1994;106:955–7.
Bourgeois IM. Electromagnetic interference and Cardiac Pacemakers. In: Atlee JL, Gombotz H, Tscheliessnigg KH (eds), Peri-operative management of pacemaker patients. Berlin, Springer Verlag, 1992, pp 70–81 (3-540-53874-7).
Knickerbocker G. Guidance article: Cellular telephones and radio transmitters-interference with clinical equipment. Health Devices, Augustus-September 1993;22(8–9):416–8.
Siemons GHA. Informatie en advies met betrekking tot mogelijke storing van medische apparatuur door draadloze telefoontoestellen. Staatstoezicht op de Volksgezondheid 1994; GHI/JK/HR 941630:1–2.
Marco D, Eisinger G, Hayes DL. Testing of work environments for electromagnetic interference. PACE 1992;15:2016–22.
Toivonen L, Valjus J, Hongisto M, Metso R. The influence of elevated 50 Hz electric and magnetic fields on implanted cardiac pacemakers: the role of the lead configuration and programming of the sensitivity. PACE 1991;14:2114–22.
Astridge PS, Kaye GC, Whitworth S, Kelly P, Camm AJ, Perrins EJ. The response of implanted dual chamber pacemakers to 50 Hz extraneous electrical interference. PACE 1993;16:1966–74.
Rodriguez F, Filimonov A, Henning A, Coughlin C, Greenberg M. Radiation-induced effects in multiprogrammable pacemakers and implantable defibrillators. PACE 1991;14:2143–53.
Hemel NM van, Hamerlijnck RPHM, Pronk KJ, Veen EP van der. Upper limit ventricular stimulation in respiratory rate responsive pacing due to electrocautery. PACE 1989;12:1720–3.
Gelder LM van, Bracke FALE, El Gamal IH. Upper rate pacing after radiofrequency catheter ablation in a minute ventilation rate adaptive DDD pacemaker. PACE 1994;17:1437–40.
Dekker E, Büller J, Schuilenburg RM. Enkele hulpmiddelen bij de diagnostiek van ‘pacemaker failure’. Ned T Geneesk 1964;108(45):2160–1.
Ruiter JH. Clinical aspects of cadiac pacing for bradyarrhythmias. Thesis. Erasmus University Rotterdam, 1992, p 268.
Buys EM, Hemel NM van, Kelder JC, Dessel PFHM van, Bakema H. Unsatisfying results in long-term pacing with a bipolar active fixation atrial lead. PACE 1994;17:2292–6.
Goethals MPN, Timmmermans W, Willems R, Andries E, Stroobandt R. Facing the ‘faces’ of pacing after implantation. In: Andries E, Brugada P, Stroobandt R (eds), How to face ‘the faces’ of cardiac pacing. Dordrecht, Kluwer Academic Publishers, 1992, pp 139–81.
Ko WH, Mugica J, Ripart A (eds), Implantable sensors for closed-loop prosthetic systems. Mount Kisco, New York, Futura Publishing Company, 1985.
Zakaria MS, Maue-Dickson W, MacGregor DC. Surgical implantation of dual chamber cardiac pacing systems. TPS Brochure 1988;1:1–10.
Stokes K, Staffenson D, Lessar J, Sahni A. A possible new complication of sublcavian stick: conductor fracture. PACE 1987;10:748.
Byrd. Safe Introducer Technique for Pacemaker Lead Implantation. PACE 1992;15:262–7.
Schuger CD, Mittleman R, Habbal B, Wagshal A, Huang SK. Ventricular lead Transection and Atrial lead damage in a young softbal player shortly after the insertion of a permanent pacemaker. PACE 1992;15:1236–9.
Byrd CL, McArthur W, Stokes K, Sivina M, Yahr WZ, Greenberg J. Implant experience with unipolar polyurethane pacing leads. PACE 1983;6:868–82.
Furman S, Benedek M. Survival of implantable pacemaker leads. PACE 1990;13:1910–4.
Stokes K. Pacing leads for rate adaptive pacing. In: Benditt DG (ed.), Rate adaptive pacing. Oxford, Blackwell Scientific Publications, 1993, pp 31–42.
Buckingham TA, Alagona P, Batey R, Belott P, Byrd CL, Gallastegui JL, Hayes DL, Johnson WB, Mead H, Parsonnet V, Reynolds DD, Simonson J, Tonder LM, Wheelan K. The use of impedance measurements to detect pacemaker lead failure during follow-up. Eur JCPE 1994;4:242–6.
Berg JW van den, Rodrigo FA, Thalen HJ, Koops J. Photo-analysis of the condition of implanted pacemakers and electrode circuits. Koninkl Nederl Akademie van Wetenschappen 1967, Proceedings Serie C, 70(4):419–47.
Amado JB, Trujillo C. Energy requirements during acute endocardial stimulation. A comparative study of different morphology leads. In: Aubert AE, Ector H (eds), Progress in Biomedical Engineering: Pacemaker leads. Amsterdam, Elsevier Science Publishers, 1985.
Ellenbogen KA. Cardiac Pacing. Boston, Blackwell Scientific Publication, 1992, p 38.
Kay GN. Basic Aspects of Cardiac Pacing. In: Ellenbogen KA, ed. Cardiac Pacing. Blackwell Scientific Publication, Boston, 1992, pp 32–119.
Zhdanov AM, Gukov AC, Termosesov SA. Evaluation of the inducability with non-invasive programmed stimulation (NIPS) of atrial arrhythmias in VVI and DDD-R mode. PACE 1993;16:1148.
Schneider H. Physical aspects of artificial heart stimulation. Thesis. Rijksuniversiteit Utrecht, 1966, p 111.
Sutton R, Guneri S. The impact of steroid eluting leads on long-term pacing in the atrium and ventricle. Eur JCPE 1991;1:10–5.
Katritsis D, Jones S, Camm AJ. A rational choice of pacemaker mode. Eur JCPE 1991;1:132–7.
Sutton R. Guest Editorial DDDR Pacing. PACE 1990;13:385–7.
Furman S. Pacemaker Follow-up. In: Furman S, Hayes DL, Holmes DR (eds), A Practice of Cardiac Pacing. Futura Publishing Company, Mount Kisco, New York, 1993, pp 571–603.
Love CJ. Clinical follow-up of rate-adaptive systems. In: Benditt DG (ed.), Rate adaptive pacing. Blackwell Scientific Publications, Oxford, 1993, pp 215–32.
Seeger W. Hertzschrittmacher Functionskontrolle. Reinbek, Sachsenwald-Druckerei, 1990.
Winter UJ, Zegelman M, Jansen B. Aktuelle Aspekte bei der Prävention, Diagnostik und Therapie von Schrittmacher-Infektionen. In: Winter UJ, Zegelman M (eds), Herzschrittmacher-und Defibrillator-Infektionen. Georg Thieme Verlag, Stuttgart, 1994, pp 1–9.
Mechelen R van, Kerckhove Y van der. Atrial capture and dual chamber pacing. PACE 1986;9.
Schoenfeld MH. Follow-up of the pacemaker patient. In: Ellenbogen KA (ed.), Cardiac Pacing. Blackwell Scientific Publication, Boston, 1992, pp 419–54.
Escher DJW, Furman S. Oscilloscopic and recent other methods of implanted pacemaker follow-up. Ann Cardiol Angéiol 1971;20:503–10.
Hayes DL, Furman S. Atrio-ventricular and ventriculo-atrial conduction time in patients undergoing pacemaker implant. PACE 1983;6:38–46.
Berkhof MMJ, Snoeck JP, Goethals MPN, Claes MJ. Clinical relevance of histograms in the follow-up of DDDR pacemakers. In: Aubert AE, Ector H, Stroobandt R (eds), Cardiac pacing and Electrophysiology; a bridge to the 21st century. Kluwer Academic Publishers, Dordrecht, 1994, pp 325–31.
Lau Chu-P, Leung SK. Clinical usefulness of rate adaptive pacing systems: what should we assess? PACE 1994;17:2233–5.
Schuring L. Educational Guidelines, Pacing and Electrophysiology. Futura Publishing Company, Muskegon Michigan, 1994.
Lau Chu-P, Mehta D, Toff WD, Stott RJ. Limitations of rate response of an activity sensing rate-responsive pacemaker to different forms of activity. PACE 1988;11:141–50.
Lewalter T, MacCarter DJ, Jung W, Schimpf R, Bauer T, Manz M, Funke H, Luderitz B. The ‘LITE’ protocol for appropriate rate adaptive pacemaker programming. PACE 1994;17:854.
Osswald ST, Kiowski W, Leiggener CH, Buser P, Pfisterer M, Burkart F. Adjustment of heart rate response of activity-sensing pacemakers by an exercise protocol mimicking daily activities. Eur JCPE 1993;4:269–77.
Froelicher VF. Manual of exercise testing. Mosby-Year Book, St. Louis, Missouri, 1994.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1995 Springer Science+Business Media Dordrecht
About this chapter
Cite this chapter
van der Kemp, P., Bakema, L. (1995). Technical Follow-up of Implanted Pacemakers. In: Van Hemel, N.M., Wittkampf, F.H.M., Ector, H. (eds) The Pacemaker Clinic of the 90’s. Developments in Cardiovascular Medicine, vol 175. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-0347-3_7
Download citation
DOI: https://doi.org/10.1007/978-94-011-0347-3_7
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-4154-6
Online ISBN: 978-94-011-0347-3
eBook Packages: Springer Book Archive