Abstract
The liver and spleen are difficult to image with ultrasound because the overlying ribs, by preventing the transmission of ultrasound, obscure portions of these organs. In addition, since regions of the liver and spleen are larger than the field of view of a realtime scanner, a cross section of either of these organs often cannot be included on a single image. However, real-time imaging of the liver has several advantages over contact scanning. Small intrahepatic lesions can be more readily identified by real-time imaging than by contact scanning because the entire volume of the liver is continuously imaged as the real-time transducer sweeps through it, whereas with contact scanning serial scans are obtained with discrete spaces between the scans. In addition, when a questionable mass is identified, it can be more readily characterized as cystic or solid by real-time than by contact scanning since the beam can be more easily manipulated perpendicular to the surface of the mass and swept through the mass from side to side so as to both define its margins and internal echo pattern.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Marks WM, Filly RA, Callen PW (1979) Ultrasonic anatomy of the liver: a review with new applications. J Clin Ultrasound 7: 137–146
Babcock DS, Kaufman L, Cosnow I (1978) Ultrasound diagnosis of hydatid disease (echinococcosis) in two cases. Am J Roentgenol 131: 895–897
Green B, Bree RL, Goldstein HM, Stanley C (1977) Gray scale ultrasound evaluation of hepatic neoplasms: patterns and correlations. Radiology 124: 203–208
Scheible W, Gosink BB, Leopold GR (1977) Gray scale echographic patterns of hepatic metastatic disease. Am J Roentgenol 129: 983–987
Wooten WB, Green B, Goldstein HM (1978) Ultrasonography of necrotic hepatic metastases. Radiology 128: 447–450
Cunningham JJ, Wooten W, Cunningham MA (1976) Gray scale echography of solu¬ble protein and protein aggregate fluid collections (in vitro study). J Clin Ultrasound 4: 417–419
Broderick TW, Gosink B, Menuck L, Harris R, Wilcox J (1980) Echographic and radionuclide detection of hepatoma. Radiology 135: 149–151
Taylor KJW, Carpenter DA, Hill CR, McCready VR (1976) Gray scale ultrasound imaging. Radiology 119: 415–423
Bernardino ME, Green B (1979) Ultrasonographic evaluation of chemotherapeutic response in hepatic metastases. Radiology 133: 437–441
Sukov RJ, Cohen LJ, Sample WF (1980) Sonography of hepatic amebic abscesses. Am J Roentgenol 134: 911–915
Merritt CRB (1979) Ultrasonographic demonstration of portal vein thrombosis. Radiology 133: 425–427
Gosink BB, Lemon SK, Scheible W, Leopold GR (1979) Accuracy of ultrasonogra¬phy in diagnosis of hepatocellular disease. Am J Roentgenol 133: 19–23
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 1981 Springer-Verlag New York Inc.
About this chapter
Cite this chapter
Skolnick, M.L. (1981). Liver and Spleen. In: Real-time Ultrasound Imaging in the Abdomen. Springer, New York, NY. https://doi.org/10.1007/978-1-4612-5919-0_5
Download citation
DOI: https://doi.org/10.1007/978-1-4612-5919-0_5
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4612-5921-3
Online ISBN: 978-1-4612-5919-0
eBook Packages: Springer Book Archive