Skip to main content

MR-Guided Cardiac Catheterization

  • Chapter
Clinical Cardiac MRI

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 109.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Atz AM, Adatia I, Lock JE, Wessel DL (1999) Combined effects of nitric oxide and oxygen during acute pulmonary vasodilator testing. J Am Coll Cardiol 33:813–819

    Article  PubMed  Google Scholar 

  • Bakker CJ, Hoogeveen RM, Weber J et al (1996) Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions. Magn Reson Med 36:816–820

    PubMed  Google Scholar 

  • Bakker CJ, Hoogeveen RM, Hurtak WF et al (1997) MR-guided endovascular interventions: susceptibility-based catheter and near-real-time imaging technique. Radiology 202:273–276

    PubMed  Google Scholar 

  • Beerbaum P, Korperich H, Barth P, et al (2001) Noninvasive quantification of left-to-right shunt in pediatric patients: phase-contrast cine magnetic resonance imaging compared with invasive oximetry. Circulation 103:2476–2482

    PubMed  Google Scholar 

  • Bellenger NG, Marcus NJ, Rajappan K, et al (2002) Comparison of techniques for the measurement of left ventricular function following cardiac transplantation. J Cardiovasc Magn Reson 4:255–263

    Article  PubMed  Google Scholar 

  • Berrington de Gonzalez A, Darby S (2004) Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries. Lancet 363:345–351

    Article  PubMed  Google Scholar 

  • Bonhoeffer P, Boudjemline Y, Qureshi SA et al (2002) Percutaneous insertion of the pulmonary valve. J Am Coll Cardiol 39:1664–1669

    Article  PubMed  Google Scholar 

  • Buecker A, Neuerburg JM, Adam GB et al (2000) Real-time MR fluoroscopy for MR-guided iliac artery stent placement. J Magn Reson Imaging 12:616–622

    Article  PubMed  Google Scholar 

  • Buecker A, Spuentrup E, Grabitz R et al (2002a) Real-time-MR guidance for placement of a self-made fully MR-compatible atrial septal occluder: in vitro test. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 174:283–285

    Article  PubMed  Google Scholar 

  • Buecker A, Spuentrup E, Grabitz R et al (2002b) Magnetic resonance-guided placement of atrial septal closure device in animal model of patent foramen ovale. Circulation 106:511–515

    Article  PubMed  Google Scholar 

  • Cigarroa RG, Lange RA, Hillis LD (1989) Oximetric quantitation of intracardiac left-to-right shunting: limitations of the Qp/Qs ratio. Am J Cardiol 64:246–247

    Article  PubMed  Google Scholar 

  • Dhingra VK, Fenwick JC, Walley KR, Chittock DR, Ronco JJ (2002) Lack of agreement between thermodilution and Fick cardiac output in critically ill patients. Chest 122:990–997

    Article  PubMed  Google Scholar 

  • Dimick RN, Hedlund LW, Herfkens RJ, Fram EK, Utz J (1987) Optimizing electrocardiograph electrode placement for cardiac-gated magnetic resonance imaging. Invest Radiol 22:17–22

    PubMed  Google Scholar 

  • Du ZD, Hijazi ZM, Kleinman CS, et al (2002) Comparison between transcatheter and surgical closure of secundum atrial septal defect in children and adults: results of a multicenter nonrandomized trial. J Am Coll Cardiol 39:1836–1844

    Article  PubMed  Google Scholar 

  • Eggers H, Weiss S, Boernert P, Boesiger P (2003) Imagebased tracking of optically detunable parallel resonant circuits. Magn Reson Med 49:1163–1174

    Article  PubMed  Google Scholar 

  • Fahrig R, Butts K, Wen Z et al (2001) Truly hybrid interventional MR/X-ray system: investigation of in vivo applications. Acad Radiol 8:1200–1207

    Article  PubMed  Google Scholar 

  • Fahrig R, Heit G, Wen Z, et al (2003) First use of a truly-hybrid X-ray/MR imaging system for guidance of brain biopsy. Acta Neurochir (Wien) 145:995–997; discussion 997

    Article  Google Scholar 

  • Faulkner K, Love HG, Sweeney JK, Bardsley RA (1986) Radiation doses and somatic risk to patients during cardiac radiological procedures. Br J Radiol 59:359–363

    PubMed  Google Scholar 

  • Glowinski A, Adam G, Bucker A, et al (1997) Catheter visualization using locally induced, actively controlled field inhomogeneities. Magn Reson Med 38:253–258

    PubMed  Google Scholar 

  • Guttman MA, Lederman RJ, Sorger JM, McVeigh ER (2002) Real-time volume rendered MRI for interventional guidance. J Cardiovasc Magn Reson 4:431–442; erratum: J Cardiovasc Magn Reson (2003) 5:407

    Article  PubMed  Google Scholar 

  • Helbing WA, Rebergen SA, Maliepaard C et al (1995) Quantification of right ventricular function with magnetic resonance imaging in children with normal hearts and with congenital heart disease. Am Heart J 130:828–837

    Article  PubMed  Google Scholar 

  • Hijazi ZM, Hakim F, Haweleh AA et al (2002) Catheter closure of perimembranous ventricular septal defects using the new Amplatzer membranous VSD occluder: initial clinical experience. Catheter Cardiovasc Interv 56:508–515

    Article  PubMed  Google Scholar 

  • Hill JM, Dick AJ, Raman VK et al (2003) Serial cardiac magnetic resonance imaging of injected mesenchymal stem cells. Circulation 108:1009–1014. Epub 11 Aug 2003

    Article  PubMed  Google Scholar 

  • Hillis LD, Winniford MD, Jackson JA, Firth BG (1985a) Measurements of left-to-right intracardiac shunting in adults: oximetric versus indicator dilution techniques. Cathet Cardiovasc Diagn 11:467–472

    PubMed  Google Scholar 

  • Hillis LD, Firth BG, Winniford MD (1985b) Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output. Am J Cardiol 56:764–768

    Article  PubMed  Google Scholar 

  • Holzer R, Balzer D, Cao QL, et al (2004a) Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal defect occluder: immediate and mid-term results of a U.S. registry. J Am Coll Cardiol 43:1257–1263

    Article  PubMed  Google Scholar 

  • Holzer R, Balzer D, Amin Z et al (2004b) Transcatheter closure of postinfarction ventricular septal defects using the new Amplatzer muscular VSD occluder: results of a US registry. Catheter Cardiovasc Interv 61:196–201

    Article  PubMed  Google Scholar 

  • Hundley WG, Li HF, Hillis LD et al (1995) Quantitation of cardiac output with velocity-encoded, phase-difference magnetic resonance imaging. Am J Cardiol 75:1250–1255

    Article  PubMed  Google Scholar 

  • ICRP (1990) Recommendations of the International Commission on Radiological Protection. ICRP 60. Ann ICRP 21:1–3

    Google Scholar 

  • Koenig PR, Abdulla RI, Cao QL, Hijazi ZM (2003) Use of intracardiac echocardiography to guide catheter closure of atrial communications. Echocardiography 20:781–787

    Article  PubMed  Google Scholar 

  • Konings MK, Bartels LW, Smits HF, Bakker CJ (2000) Heating around intravascular guide wires by resonating RF waves. J Magn Reson Imaging 12:79–85

    Article  PubMed  Google Scholar 

  • Kovoor P, Ricciardello M, Collins L, Uther JB, Ross DL (1998) Risk to patients from radiation associated with radiofrequency ablation for supraventricular tachycardia. Circulation 98:1534–1540

    PubMed  Google Scholar 

  • Kuehne T, Fahrig R, Butts K (2003a) Pair of resonant fiducial markers for localization of endovascular catheters at all catheter orientations. J Magn Reson Imaging 17:620–624

    Article  PubMed  Google Scholar 

  • Kuehne T, Saeed M, Higgins CB et al (2003b) Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. Radiology 226:475–481

    Google Scholar 

  • Ladd ME, Erhart P, Debatin JF et al (1997) Guide wire antennas for MR fluoroscopy. Magn Reson Med 37:891–897

    PubMed  Google Scholar 

  • Ladd ME, Zimmermann GG, Quick HH et al (1998a) Active MR visualization of a vascular guide wire in vivo. J Magn Reson Imaging 8:220–225

    PubMed  Google Scholar 

  • Ladd ME, Zimmermann GG, McKinnon GC et al (1998b) Visualization of vascular guide wires using MR tracking. J Magn Reson Imaging 8:251–253

    PubMed  Google Scholar 

  • Leung DA, Debatin JF, Wildermuth S et al (1995) Intravascular MR tracking catheter: preliminary experimental evaluation. AJR Am J Roentgenol 164:1265–1270

    PubMed  Google Scholar 

  • Liu H, Hall WA, Martin AJ, Maxwell RE, Truwit CL (2000) MR-guided and MR-monitored neurosurgical procedures at 1.5 T. J Comput Assist Tomogr 24:909–918

    Article  PubMed  Google Scholar 

  • Magee AG, Nykanen D, McCrindle BW, et al (1997) Balloon dilation of severe aortic stenosis in the neonate: comparison of anterograde and retrograde catheter approaches. J Am Coll Cardiol 30:1061–1066

    Article  PubMed  Google Scholar 

  • Magee AG, Brzezinska-Rajszys G, Qureshi SA et al (1999) Stent implantation for aortic coarctation and recoarctation. Heart 82:600–606

    PubMed  Google Scholar 

  • Magni G, Hijazi ZM, Pandian NG et al (1997) Two-and three-dimensional transesophageal echocardiography in patient selection and assessment of atrial septal defect closure by the new DAS-Angel Wings device: initial clinical experience. Circulation 96:1722–1728

    PubMed  Google Scholar 

  • Miquel ME, Hill DL, Baker EJ et al (2003) Three-and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images. Int J Cardiovasc Imaging 19:239–254; discussion 255–256

    Article  PubMed  Google Scholar 

  • Miquel ME, Hegde S, Muthurangu V et al (2004) Visualization and tracking of an inflatable balloon catheter using SSFP in a flow phantom and in the heart and great vessels of patients. Magn Reson Med 51:988–995

    Article  PubMed  Google Scholar 

  • Modan B, Keinan L, Blumstein T, Sadetzki S (2000) Cancer following cardiac catheterization in childhood. Int J Epidemiol 29:424–428

    Article  PubMed  Google Scholar 

  • Muthurangu V, Taylor AM, Andriantsimiavona R et al (2004) A novel method of quantifying pulmonary vascular resistance utilizing simultaneous invasive pressure monitoring and phase-contrast MR flow. Circulation (in press)

    Google Scholar 

  • Nitz WR, Oppelt A, Renz W, et al (2001) On the heating of linear conductive structures as guide wires and catheters in interventional MRI. J Magn Reson Imaging 13:105–114

    Article  PubMed  Google Scholar 

  • NRPB (1999) Guidelines on patient dose to promote the optimisation of protection for diagnostic medical exposures. National Radiation Protection Board 10:1

    Google Scholar 

  • Ocali O, Atalar E (1997) Intravascular magnetic resonance imaging using a loopless catheter antenna. Magn Reson Med 37:112–118

    PubMed  Google Scholar 

  • Omary RA, Unal O, Koscielski DS et al (2000) Real-time MR imaging-guided passive catheter tracking with use of gadolinium-filled catheters. J Vasc Interv Radiol 11:1079–1085

    PubMed  Google Scholar 

  • Pihkala J, Nykanen D, Freedom RM, Benson LN (1999) Interventional cardiac catheterization. Pediatr Clin North Am 46:441–464

    Article  PubMed  Google Scholar 

  • Rao PS, Galal O, Patnana M, Buck SH, Wilson AD (1998) Results of 3 to 10 year follow up of balloon dilatation of the pulmonary valve. Heart 80:591–595

    PubMed  Google Scholar 

  • Razavi R, Baker E (1999) Magnetic resonance imaging comes of age. Cardiol Young 9:529–538

    PubMed  Google Scholar 

  • Razavi RS, Baker A, Qureshi SA et al (2001) Hemodynamic response to continuous infusion of dobutamine in Alagille’s syndrome. Transplantation 72:823–828

    Article  PubMed  Google Scholar 

  • Razavi RS, Hill DL, Muthurangu V et al (2003a) Three-dimensional magnetic resonance imaging of congenital cardiac anomalies. Cardiol Young 13:461–465

    PubMed  Google Scholar 

  • Razavi R, Hill DL, Keevil SF et al (2003b) Cardiac catheterisation guided by MRI in children and adults with congenital heart disease. Lancet 362:1877–1882

    Article  PubMed  Google Scholar 

  • Rhode KS, Hill DLG, Edwards PJ et al (2003) Registration and tracking to integrate X-ray and MR images in an XMR facility. IEEE Trans Med Imaging 22:1369–1378

    Article  PubMed  Google Scholar 

  • Rickers C, Seethamraju RT, Jerosch-Herold M, Wilke NM (2003) Magnetic resonance imaging guided cardiovascular interventions in congenital heart diseases. J Interv Cardiol 16:143–147

    PubMed  Google Scholar 

  • Robertson MB, Kohler U, Hoskins PR, Marshall I (2001) Quantitative analysis of PC MRI velocity maps: pulsatile flow in cylindrical vessels. Magn Reson Imaging 19:685–695

    Article  PubMed  Google Scholar 

  • Schalla S, Saeed M, Higgins CB, et al (2003) Magnetic resonance-guided cardiac catheterization in a swine model of atrial septal defect. Circulation 108:1865–1870

    Article  PubMed  Google Scholar 

  • Serfaty JM, Yang X, Aksit P, et al (2000) Toward MRI-guided coronary catheterization: visualization of guiding catheters, guide wires, and anatomy in real time. J Magn Reson Imaging 12:590–594

    Article  PubMed  Google Scholar 

  • Shellock FG (1989) Biological effects and safety aspects of magnetic resonance imaging. Magn Reson Q 5:243–261

    PubMed  Google Scholar 

  • Shellock FG, Kanal E (1991) Policies, guidelines, and recommendations for MR imaging safety and patient management. SMRI Safety Committee. J Magn Reson Imaging 1:97–101

    PubMed  Google Scholar 

  • Shellock FG, Kanal E (1996) Burns associated with the use of monitoring equipment during MR procedures. J Magn Reson Imaging 6:271–272

    PubMed  Google Scholar 

  • Shellock FG, Shellock VJ (1998) Cardiovascular catheters and accessories: ex vivo testing of ferromagnetism, heating, and artifacts associated with MRI. J Magn Reson Imaging 8:1338–1342

    PubMed  Google Scholar 

  • Shellock FG, Shellock VJ (1999) Metallic stents: evaluation of MR imaging safety. AJR Am J Roentgenol 173:543–547

    PubMed  Google Scholar 

  • Silverman NH, Schiller NB (1978) Apex echocardiography. A two-dimensional technique for evaluating congenital heart disease. Circulation 57:503–511

    PubMed  Google Scholar 

  • Snider AR, Silverman NH (1981) Suprasternal notch echocardiography: a two-dimensional technique for evaluating congenital heart disease. Circulation 63:165–173

    PubMed  Google Scholar 

  • Spuentrup E, Ruebben A, Schaeffter T, et al (2002) Magnetic resonance-guided coronary artery stent placement in a swine model. Circulation 105:874–879

    Article  PubMed  Google Scholar 

  • Wong EY, Zhang Q, Duerk JL, Lewin JS, Wendt M (2000) An optical system for wireless detuning of parallel resonant circuits. J Magn Reson Imaging 12:632–638

    Article  PubMed  Google Scholar 

  • Yeung CJ, Susil RC, Atalar E (2002a) RF safety of wires in interventional MRI: using a safety index. Magn Reson Med 47:187–193

    Article  PubMed  Google Scholar 

  • Yeung CJ, Susil RC, Atalar E (2002b) RF heating due to conductive wires during MRI depends on the phase distribution of the transmit field. Magn Reson Med 48:1096–1098

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2005 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Razavi, R., Muthurangu, V., Hegde, S.R., Taylor, A.M. (2005). MR-Guided Cardiac Catheterization. In: Bogaert, J., Dymarkowski, S., Taylor, A.M. (eds) Clinical Cardiac MRI. Medical Radiology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-26997-5_17

Download citation

  • DOI: https://doi.org/10.1007/3-540-26997-5_17

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-40170-4

  • Online ISBN: 978-3-540-26997-7

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics